PTA Balloon Dilatation Catheter
The PTA Balloon Dilatation Catheter is an over-the-wire (OTW) type catheter with platinum-iridium alloy radiopaque markers. It features a coated surface from the distal tip to the proximal end of the balloon. The catheter is composed of a balloon, a soft tip, an inner tip, a shrink tube, a stress buffer, a Y-connector, and a catheter shaft. Materials include Pebax7033 and Vestamid L2101F for the balloon, Pebax7033 for the soft tip, Grilamid L20 for the inner tip, Pebax6333 for the shrink tube, ethylene-vinyl acetate copolymer for the stress buffer, Pebax7033 for the Y-connector, and Pebax7033 with BaSO4 for the catheter shaft. The coating consists of silicone oil and silicone lubricant 360. The product is sterilized with ethylene oxide and is for single use only.
Product English Name:
PTA Balloon Dilatation Catheter
Alias:
Peripheral Transluminal Angioplasty Catheter,Balloon Catheter
Intended Use:
The PTA Balloon Dilatation Catheter is designed for dilating stenoses in peripheral arteries, treating primary occlusive lesions or complex arteriovenous fistulas, and/or re-expanding endoluminal stent elements in the aorta and iliac arteries.
Product Introduction

The PTA Balloon Dilatation Catheter is a specialized medical device used in interventional radiology and cardiology. It is engineered to provide precise and controlled dilation of narrowed or blocked arteries, facilitating improved blood flow. The catheter's design incorporates advanced materials and coatings to ensure smooth navigation through vascular pathways and effective treatment of arterial lesions.

1. The PTA Balloon Dilatation Catheter is characterized by its high flexibility and radiopacity, allowing for accurate placement and visualization under fluoroscopy. The platinum-iridium alloy markers ensure precise positioning during procedures.
2. The catheter's structure includes a balloon made from Pebax7033 and Vestamid L2101F, a soft tip for atraumatic navigation, and a stress buffer to reduce mechanical stress during inflation. The Y-connector facilitates easy connection to other medical devices.
3. This catheter is primarily used in peripheral artery interventions, including the treatment of stenoses, occlusive lesions, and arteriovenous fistulas. It is also effective in re-expanding stents in the aorta and iliac arteries, making it a versatile tool in vascular surgery.

The PTA Balloon Dilatation Catheter, also known as the Peripheral Transluminal Angioplasty Catheter, is a highly specialized device designed for precise arterial dilation. Its advanced materials and coatings ensure smooth operation, while its radiopaque markers allow for accurate placement. This catheter is a reliable choice for treating a variety of vascular conditions.

Main Features

The PTA Balloon Dilatation Catheter offers precise dilation of arterial stenoses, effective treatment of occlusive lesions, and re-expansion of stents. Its design ensures smooth navigation and accurate placement, making it a versatile tool in vascular interventions.

1. The catheter's balloon is made from high-quality materials, ensuring durability and effective dilation. The Pebax7033 and Vestamid L2101F construction provides the necessary flexibility and strength for various vascular conditions.
2. The soft tip design minimizes trauma during insertion, allowing for atraumatic navigation through complex vascular pathways. This feature is crucial for patient safety and procedural success.
3. The stress buffer reduces mechanical stress during balloon inflation, preventing damage to the catheter and ensuring consistent performance. This feature enhances the catheter's reliability during prolonged procedures.
4. The Y-connector facilitates easy connection to other medical devices, streamlining the procedure and reducing setup time. This feature is particularly useful in complex interventions requiring multiple devices.
5. The catheter's radiopaque markers ensure precise placement under fluoroscopy, allowing for accurate treatment of arterial lesions. This feature is essential for achieving optimal clinical outcomes.

The PTA Balloon Dilatation Catheter is a highly effective tool for vascular interventions, offering precise dilation, atraumatic navigation, and reliable performance. Its advanced features make it a preferred choice for treating arterial stenoses and occlusive lesions.

Clinical Applications

The PTA Balloon Dilatation Catheter is widely used in clinical settings for the treatment of peripheral artery disease, including stenoses, occlusive lesions, and arteriovenous fistulas. It is also effective in re-expanding stents in the aorta and iliac arteries.

1. In peripheral artery interventions, the catheter is used to dilate stenoses, improving blood flow and alleviating symptoms of peripheral artery disease. Its precise placement ensures effective treatment with minimal complications.
2. The catheter is effective in treating primary occlusive lesions, restoring blood flow to affected areas and preventing further vascular damage. Its atraumatic design minimizes the risk of vessel injury during the procedure.
3. For complex arteriovenous fistulas, the catheter provides controlled dilation, facilitating the creation of functional fistulas for dialysis access. Its flexibility and strength ensure successful outcomes in these challenging cases.
4. In aortic and iliac artery interventions, the catheter is used to re-expand endoluminal stents, maintaining vessel patency and preventing restenosis. Its radiopaque markers allow for accurate placement and effective treatment.
5. The catheter's versatility makes it suitable for a wide range of vascular conditions, from simple stenoses to complex occlusive lesions. Its advanced features ensure reliable performance in various clinical scenarios.

The PTA Balloon Dilatation Catheter is a versatile and reliable tool for treating a wide range of vascular conditions. Its precise placement, atraumatic design, and effective dilation make it a preferred choice in clinical settings.

Purchasing Guide

When purchasing the PTA Balloon Dilatation Catheter, consider factors such as product specifications, types, budget, and intended use. Proper selection ensures optimal performance and cost-effectiveness.

1. Product specifications, including balloon size, catheter length, and material composition, should be carefully evaluated to match the specific clinical needs. This ensures the catheter's effectiveness in the intended application.
2. Different types of PTA Balloon Dilatation Catheters are available, each designed for specific vascular conditions. Selecting the appropriate type is crucial for achieving the desired clinical outcomes.
3. Budget considerations are important when purchasing medical devices. While the PTA Balloon Dilatation Catheter offers advanced features, it is essential to balance cost with the expected benefits and outcomes.
4. The intended use of the catheter, whether for peripheral artery interventions, aortic stent re-expansion, or arteriovenous fistula creation, should guide the selection process. This ensures the catheter's suitability for the specific clinical scenario.

Purchasing the PTA Balloon Dilatation Catheter requires careful consideration of product specifications, types, budget, and intended use. Proper selection ensures optimal performance and cost-effectiveness, making it a valuable addition to any vascular intervention toolkit.

 Precautions

When using the PTA Balloon Dilatation Catheter, it is essential to follow proper handling and usage guidelines to ensure patient safety and procedural success. Key precautions include proper sterilization, correct placement, and monitoring for potential complications.

1. Ensure the catheter is properly sterilized before use, as it is intended for single use only. Reuse can lead to contamination and increased risk of infection.
2. Correct placement of the catheter is crucial for effective treatment. Use fluoroscopy to guide the catheter to the target site, ensuring accurate dilation of the arterial lesion.
3. Monitor the patient for potential complications, such as vessel dissection or rupture, during and after the procedure. Prompt intervention can mitigate these risks.
4. Follow the manufacturer's guidelines for balloon inflation and deflation to prevent damage to the catheter and ensure consistent performance. Overinflation can lead to vessel injury, while underinflation may result in ineffective treatment.
5. Proper disposal of the catheter after use is essential to prevent contamination and ensure compliance with medical waste regulations. Follow local guidelines for the disposal of single-use medical devices.

Using the PTA Balloon Dilatation Catheter requires careful attention to handling, placement, and monitoring. Proper sterilization, accurate placement, and adherence to usage guidelines are essential for ensuring patient safety and procedural success. By following these precautions, healthcare providers can maximize the catheter's effectiveness and minimize risks.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files