The OTW Balloon Dilatation Catheter is a specialized medical device designed for minimally invasive procedures to treat arterial stenosis. Its advanced design ensures precise delivery and effective dilatation, making it a reliable tool for interventional cardiologists. The catheter's hydrophilic coating and radiopaque markers enhance its usability and accuracy during procedures.
1. The OTW Balloon Dilatation Catheter is characterized by its high flexibility and pushability, allowing smooth navigation through complex vascular structures. Its hydrophilic coating reduces friction, ensuring minimal trauma to the vessel walls.
2. The catheter's structure includes a proximal section with an outer and inner push rod, bonded to a Luer connector, and a distal section with a Pebax tip, Pellethane balloon, and a three-layer inner push rod. The radiopaque marker band ensures precise positioning under imaging.
3. This catheter is primarily used for balloon dilatation in coronary arteries and bypass grafts. It is particularly effective in treating stenosis, improving blood flow, and enhancing myocardial perfusion in patients with cardiovascular conditions.
The OTW Balloon Dilatation Catheter, also known as the Over-the-Wire Balloon Catheter, is a versatile and reliable tool for treating arterial stenosis. Its advanced design, including a hydrophilic coating and radiopaque markers, ensures precise and effective procedures. Whether you're navigating complex vasculature or restoring blood flow, this catheter delivers consistent performance.
The OTW Balloon Dilatation Catheter offers exceptional flexibility, pushability, and precision, making it ideal for treating arterial stenosis. Its hydrophilic coating and radiopaque markers enhance usability and accuracy during procedures.
1. The catheter's high flexibility allows it to navigate through tortuous vascular structures with ease, reducing the risk of vessel damage.
2. Its pushability ensures effective force transmission from the proximal to the distal end, enabling precise balloon placement.
3. The hydrophilic coating minimizes friction, facilitating smooth catheter movement and reducing trauma to the vessel walls.
4. Radiopaque markers provide clear visualization under imaging, ensuring accurate positioning during procedures.
5. The catheter's design is optimized for single-use, ensuring sterility and reducing the risk of cross-contamination.
The OTW Balloon Dilatation Catheter stands out for its flexibility, pushability, and precision. Its hydrophilic coating and radiopaque markers make it a reliable choice for interventional cardiologists. Whether you're navigating complex vasculature or ensuring accurate balloon placement, this catheter delivers consistent performance.
The OTW Balloon Dilatation Catheter is widely used in clinical settings for treating arterial stenosis, particularly in coronary arteries and bypass grafts. Its design ensures effective dilatation and improved blood flow.
1. In coronary artery disease, the catheter is used to dilate narrowed sections of the arteries, restoring blood flow and improving myocardial perfusion.
2. For patients with bypass grafts, the catheter helps address stenosis, ensuring the graft remains functional and effective.
3. The catheter is also used in peripheral artery disease to treat stenosis in the brachial and femoral arteries, improving circulation.
4. Its radiopaque markers and hydrophilic coating make it particularly useful in complex cases where precise positioning is critical.
5. The catheter's single-use design ensures sterility, reducing the risk of infection in clinical settings.
The OTW Balloon Dilatation Catheter is a trusted tool in clinical practice, particularly for treating arterial stenosis in coronary arteries and bypass grafts. Its precision and ease of use make it a go-to choice for interventional cardiologists, ensuring improved patient outcomes.
When purchasing the OTW Balloon Dilatation Catheter, consider factors such as product specifications, types, budget, and intended use to ensure the best fit for your clinical needs.
1. Product parameters: Evaluate the catheter's diameter, length, and balloon size to ensure compatibility with your procedures.
2. Product types: Choose between different models based on specific clinical requirements, such as flexibility and pushability.
3. Budget: Consider the cost-effectiveness of the catheter, balancing quality and affordability.
4. Usage scenarios: Assess the catheter's suitability for various clinical applications, such as coronary or peripheral artery procedures.
Purchasing the OTW Balloon Dilatation Catheter requires careful consideration of product specifications, types, and budget. By evaluating these factors, you can ensure the catheter meets your clinical needs and delivers optimal performance.
When using the OTW Balloon Dilatation Catheter, it is essential to follow proper handling and procedural guidelines to ensure patient safety and device effectiveness.
1. Ensure the catheter is properly sterilized and stored before use to prevent contamination.
2. Follow the manufacturer's instructions for insertion and navigation to avoid vessel damage.
3. Monitor the patient's vital signs and imaging during the procedure to ensure accurate balloon placement.
4. Dispose of the catheter properly after single use to prevent cross-contamination.
5. Train staff on proper handling and usage techniques to maximize the catheter's effectiveness and safety.
Using the OTW Balloon Dilatation Catheter requires attention to detail and adherence to safety guidelines. By following proper handling and procedural protocols, you can ensure the catheter performs effectively and safely, delivering optimal patient outcomes.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.