The N-Acetyl-β-D-Glucosaminidase Assay Kit (MNP-GlcNAc Substrate Method) is a specialized diagnostic tool used to measure the activity of the enzyme NAG in human urine. This enzyme is a marker for renal tubular damage, and its levels can provide critical insights into kidney health. The kit is designed for ease of use, with a straightforward protocol that ensures accurate and reliable results.
1. The kit features a highly sensitive substrate, MNP-GlcNAc, which reacts specifically with NAG to produce a measurable signal. This ensures precise detection of the enzyme's activity.
2. The composition includes a citrate buffer system that maintains optimal pH conditions for the enzymatic reaction, enhancing the stability and accuracy of the assay.
3. The primary use of this kit is in clinical settings for the diagnosis and monitoring of kidney diseases, particularly those affecting the renal tubules.
The N-Acetyl-β-D-Glucosaminidase Assay Kit, also known as the NAG Assay Kit, is a vital tool in clinical diagnostics. Its design, featuring MNP-GlcNAc and a citrate buffer, ensures accurate measurement of NAG levels, which are crucial for assessing kidney health. This kit is a reliable choice for healthcare professionals focused on renal diagnostics.
The main features of this kit include high sensitivity, specificity, and ease of use, making it an essential tool for clinical diagnostics.
1. High sensitivity: The MNP-GlcNAc substrate ensures precise detection of NAG activity, even at low concentrations.
2. Specificity: The kit is designed to react specifically with NAG, minimizing interference from other enzymes.
3. Stability: The citrate buffer system maintains optimal pH, ensuring consistent results over time.
4. Ease of use: The kit comes with a straightforward protocol, making it accessible for routine clinical use.
5. Reliability: The kit provides consistent and reproducible results, essential for accurate diagnosis.
The N-Acetyl-β-D-Glucosaminidase Assay Kit stands out for its high sensitivity, specificity, and reliability. Its user-friendly design and stable buffer system make it a dependable choice for clinical diagnostics, particularly in the assessment of kidney health.
This kit is widely used in clinical settings for the diagnosis and monitoring of kidney diseases, particularly those affecting the renal tubules.
1. Diagnosis of renal tubular damage: The kit is used to detect elevated levels of NAG, indicating damage to the renal tubules.
2. Monitoring kidney function: Regular use of the kit helps in tracking the progression of kidney diseases.
3. Early detection of kidney disease: The kit can identify early signs of kidney dysfunction, allowing for timely intervention.
4. Research applications: The kit is also used in research studies to understand the role of NAG in various kidney conditions.
5. Clinical trials: The kit is employed in clinical trials to evaluate the efficacy of new treatments for kidney diseases.
The N-Acetyl-β-D-Glucosaminidase Assay Kit is a versatile tool in clinical practice, aiding in the diagnosis, monitoring, and research of kidney diseases. Its ability to detect early signs of renal tubular damage makes it invaluable in both clinical and research settings.
This guide provides essential information for purchasing the N-Acetyl-β-D-Glucosaminidase Assay Kit, including product specifications, types, budget considerations, and usage scenarios.
1. Product parameters: The kit includes specific concentrations of MNP-GlcNAc and citrate buffer, ensuring optimal performance.
2. Product types: The kit is available in various sizes to accommodate different laboratory needs.
3. Budget considerations: The cost of the kit varies based on the quantity and supplier, so it's important to compare prices.
4. Usage scenarios: The kit is suitable for both routine clinical use and research applications, making it a versatile choice.
When purchasing the N-Acetyl-β-D-Glucosaminidase Assay Kit, it's important to consider the specific parameters, types, and budget. The kit's versatility makes it suitable for a range of clinical and research applications, ensuring value for money.
Proper handling and storage of the N-Acetyl-β-D-Glucosaminidase Assay Kit are essential to ensure accurate results and maintain the integrity of the reagents.
1. Storage conditions: The kit should be stored at the recommended temperature to prevent degradation of the reagents.
2. Handling: Always wear appropriate protective equipment when handling the kit to avoid contamination.
3. Expiration date: Ensure that the kit is used before the expiration date to guarantee accurate results.
4. Disposal: Follow proper disposal procedures for used reagents and materials to comply with safety regulations.
5. Calibration: Regularly calibrate the equipment used with the kit to maintain accuracy.
To ensure the best results with the N-Acetyl-β-D-Glucosaminidase Assay Kit, it's crucial to follow proper storage, handling, and disposal procedures. Regular calibration of equipment and adherence to safety protocols will help maintain the kit's performance and reliability.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.