The N-terminal pro-brain natriuretic peptide calibrator is a critical tool in clinical diagnostics, particularly for the accurate measurement of NT-proBNP levels in human serum or plasma. This calibrator ensures that diagnostic systems like the Caris200 provide reliable and consistent results, which are essential for the diagnosis and management of heart failure. The calibrator comes in two forms, each with a specific concentration, allowing for a broad range of calibration points to ensure accuracy across different sample types and concentrations.
1. The N-terminal pro-brain natriuretic peptide calibrator is characterized by its high precision and stability. The lyophilized form ensures long-term storage without degradation, and the inclusion of thimerosal as a preservative maintains the integrity of the antigen. This makes the calibrator reliable for use in various clinical settings, ensuring consistent results over time.
2. The calibrator is composed of two main components: Calibrator 1 and Calibrator 2. Both are lyophilized preparations of NT-proBNP antigen, preserved with thimerosal. When reconstituted with deionized water, Calibrator 1 approximates a concentration of 100 pg/mL, while Calibrator 2 approximates 1000 pg/mL. This dual-concentration setup allows for a wide range of calibration points, ensuring accuracy across different sample types and concentrations.
3. The primary use of the N-terminal pro-brain natriuretic peptide calibrator is to calibrate the Caris200 system for the quantitative determination of NT-proBNP in human serum or plasma. Accurate calibration is crucial for diagnosing and monitoring heart failure, as NT-proBNP levels are a key biomarker in assessing cardiac function. The calibrator ensures that the diagnostic system provides reliable and consistent results, which are essential for effective patient management.
The N-terminal pro-brain natriuretic peptide calibrator, also known as NT-proBNP calibrator or ProBNP standard, is a vital component in clinical diagnostics. Its high precision, stability, and dual-concentration setup make it an indispensable tool for ensuring accurate and reliable measurements of NT-proBNP levels. This, in turn, is crucial for the diagnosis and management of heart failure, highlighting the importance of this calibrator in modern healthcare.
The N-terminal pro-brain natriuretic peptide calibrator is designed to provide high precision and stability in the calibration of diagnostic systems. Its dual-concentration setup allows for a wide range of calibration points, ensuring accuracy across different sample types and concentrations.
1. High Precision: The calibrator is formulated to provide highly accurate calibration points, ensuring that diagnostic systems like the Caris200 deliver reliable and consistent results. This precision is crucial for the accurate measurement of NT-proBNP levels, which are key in diagnosing and monitoring heart failure.
2. Stability: The lyophilized form of the calibrator ensures long-term stability, allowing for extended storage without degradation. This stability is maintained by the inclusion of thimerosal as a preservative, which protects the antigen from degradation over time.
3. Dual-Concentration Setup: The calibrator comes in two concentrations—100 pg/mL and 1000 pg/mL—allowing for a broad range of calibration points. This setup ensures that the diagnostic system can accurately measure NT-proBNP levels across different sample types and concentrations.
4. Ease of Use: The calibrator is easy to reconstitute with deionized water, making it convenient for use in clinical settings. This ease of use ensures that the calibration process is straightforward and can be performed quickly, minimizing downtime in the diagnostic process.
5. Compatibility: The calibrator is specifically designed for use with the Caris200 system, ensuring seamless integration and optimal performance. This compatibility ensures that the diagnostic system operates at its highest potential, providing accurate and reliable results.
The N-terminal pro-brain natriuretic peptide calibrator stands out for its high precision, stability, and dual-concentration setup. These features make it an essential tool for ensuring accurate and reliable measurements of NT-proBNP levels, which are crucial for the diagnosis and management of heart failure. Its ease of use and compatibility with the Caris200 system further enhance its value in clinical diagnostics.
The N-terminal pro-brain natriuretic peptide calibrator is primarily used in clinical settings to ensure the accurate measurement of NT-proBNP levels in human serum or plasma. This is crucial for the diagnosis and management of heart failure, as NT-proBNP levels are a key biomarker in assessing cardiac function.
1. Diagnosis of Heart Failure: The calibrator is used to ensure the accurate measurement of NT-proBNP levels, which are a key biomarker in the diagnosis of heart failure. Accurate measurement is crucial for early detection and effective management of the condition.
2. Monitoring Treatment: The calibrator is also used to monitor the effectiveness of treatment for heart failure. By providing accurate and consistent measurements of NT-proBNP levels, the calibrator helps clinicians assess the progress of treatment and make necessary adjustments.
3. Risk Assessment: The calibrator is used in risk assessment for patients with suspected heart failure. Accurate measurement of NT-proBNP levels helps clinicians assess the severity of the condition and determine the appropriate course of action.
4. Research and Development: The calibrator is also used in research and development to study the role of NT-proBNP in various cardiac conditions. Accurate calibration ensures that research findings are reliable and can be used to develop new diagnostic and treatment methods.
5. Quality Control: The calibrator is used in quality control processes to ensure that diagnostic systems like the Caris200 provide accurate and consistent results. This is crucial for maintaining the reliability of diagnostic tests in clinical settings.
The N-terminal pro-brain natriuretic peptide calibrator plays a crucial role in the diagnosis, monitoring, and management of heart failure. Its use in clinical settings ensures accurate and reliable measurements of NT-proBNP levels, which are essential for effective patient care. Additionally, its application in research and quality control further highlights its importance in modern healthcare.
When purchasing the N-terminal pro-brain natriuretic peptide calibrator, it is important to consider factors such as product specifications, types, budget, and intended use. This guide provides essential information to help you make an informed decision.
1. Product Specifications: Ensure that the calibrator meets the required specifications for use with the Caris200 system. This includes the concentration levels (100 pg/mL and 1000 pg/mL) and the presence of thimerosal as a preservative.
2. Product Types: The calibrator is available in two types—Calibrator 1 and Calibrator 2. Both are lyophilized preparations of NT-proBNP antigen, preserved with thimerosal. Ensure that you purchase the correct type based on your diagnostic needs.
3. Budget: Consider your budget when purchasing the calibrator. While it is essential to ensure accuracy and reliability, it is also important to find a product that fits within your financial constraints.
4. Intended Use: Consider the intended use of the calibrator. Whether for clinical diagnostics, research, or quality control, ensure that the product you choose is suitable for your specific needs.
Purchasing the N-terminal pro-brain natriuretic peptide calibrator requires careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that you select a product that meets your diagnostic needs and provides accurate and reliable results.
When using the N-terminal pro-brain natriuretic peptide calibrator, it is important to follow certain precautions to ensure accurate results and maintain the integrity of the product. This section outlines key precautions to consider.
1. Storage Conditions: Store the calibrator in a cool, dry place, away from direct sunlight. The lyophilized form should be kept at the recommended temperature to maintain stability and prevent degradation.
2. Reconstitution: Follow the manufacturer's instructions for reconstituting the calibrator with deionized water. Ensure that the correct volume of water is used to achieve the desired concentration.
3. Handling: Handle the calibrator with care to avoid contamination. Use sterile techniques when reconstituting and handling the product to prevent the introduction of foreign substances.
4. Expiration Date: Check the expiration date before using the calibrator. Using an expired product can lead to inaccurate results and compromise the integrity of your diagnostic tests.
5. Disposal: Dispose of any unused or expired calibrator according to local regulations. Proper disposal is essential to prevent environmental contamination and ensure safety.
Using the N-terminal pro-brain natriuretic peptide calibrator requires careful attention to storage conditions, reconstitution, handling, expiration dates, and disposal. By following these precautions, you can ensure accurate results and maintain the integrity of the product, ultimately contributing to reliable diagnostic outcomes.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.