Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
25-Hydroxy Vitamin D Detection Kit (Dry Immunofluorescence Method)
The 25-Hydroxy Vitamin D Detection Kit is composed of a dry immunofluorescence-based detection card, sample processing solution, instruction manual, SD card, and optional pipettes. The detection card includes a test strip with a sample pad, nitrocellulose membrane, monoclonal antibodies, antigens, and absorbent paper. The sample processing solution contains NaOH, sodium acetate, and DTT salt solution, with a pH of 14±1. The kit is available in various packaging sizes to accommodate different testing needs.
Product English Name:
25-Hydroxy Vitamin D Detection Kit (Dry Immunofluorescence Method)
Alias:
25-OH-VD Kit,Vitamin D Test Kit
Intended Use:
This kit is designed for the clinical in vitro quantitative detection of 25-hydroxy vitamin D levels in human serum, plasma, or whole blood. It is widely used in medical diagnostics to assess vitamin D status, which is crucial for bone health, immune function, and overall well-being.
Product Introduction

The 25-Hydroxy Vitamin D Detection Kit is a state-of-the-art diagnostic tool that utilizes dry immunofluorescence technology to accurately measure vitamin D levels in human samples. It is designed for ease of use, reliability, and precision, making it an essential tool for healthcare professionals. The kit includes all necessary components for efficient testing, ensuring consistent and accurate results.

1. The kit features advanced dry immunofluorescence technology, which ensures high sensitivity and specificity in detecting 25-hydroxy vitamin D levels. This method is known for its rapid results and minimal sample preparation.
2. The detection card is composed of multiple layers, including a sample pad, nitrocellulose membrane, and absorbent paper, which work together to facilitate the immunoassay process. The inclusion of monoclonal antibodies and antigens ensures precise detection of vitamin D levels.
3. The kit is used in clinical settings to assess vitamin D status, which is critical for diagnosing and managing conditions related to vitamin D deficiency or excess. It is particularly useful in monitoring patients with bone disorders, immune deficiencies, or other health conditions influenced by vitamin D levels.

The 25-Hydroxy Vitamin D Detection Kit, also known as the 25-OH-VD Kit, is a reliable and efficient tool for measuring vitamin D levels. Its advanced technology and comprehensive components make it a valuable asset in clinical diagnostics, helping healthcare providers make informed decisions about patient care.

Main Features

The 25-Hydroxy Vitamin D Detection Kit offers high accuracy, ease of use, and rapid results. It is designed for clinical settings, providing reliable measurements of vitamin D levels in human samples.

1. High sensitivity and specificity: The kit uses dry immunofluorescence technology to ensure accurate detection of 25-hydroxy vitamin D levels.
2. Rapid results: The immunoassay process is designed to deliver quick and reliable results, reducing waiting times for patients and healthcare providers.
3. Minimal sample preparation: The kit requires only a small amount of serum, plasma, or whole blood, making it convenient for both patients and medical staff.
4. Comprehensive components: The kit includes all necessary materials, such as detection cards, sample processing solution, and an instruction manual, ensuring a seamless testing process.
5. Versatile packaging: The kit is available in various sizes, accommodating different testing needs and ensuring flexibility in clinical settings.

The 25-Hydroxy Vitamin D Detection Kit stands out for its accuracy, speed, and convenience. Its advanced features and comprehensive design make it an indispensable tool for healthcare professionals, enabling them to provide better care for their patients.

Clinical Applications

The 25-Hydroxy Vitamin D Detection Kit is widely used in clinical settings to assess vitamin D levels, which are critical for diagnosing and managing various health conditions.

1. Bone health: The kit is used to monitor vitamin D levels in patients with osteoporosis, rickets, or other bone-related disorders.
2. Immune function: Vitamin D plays a crucial role in immune system regulation, and the kit helps in assessing its levels in patients with immune deficiencies.
3. Chronic diseases: The kit is used in the management of chronic conditions such as diabetes, cardiovascular diseases, and autoimmune disorders, where vitamin D levels are often monitored.
4. Pediatric care: The kit is employed in pediatric settings to ensure proper vitamin D levels in children, which is essential for healthy growth and development.
5. Geriatric care: Elderly patients often require vitamin D monitoring due to age-related deficiencies, and the kit provides accurate measurements for effective management.

The 25-Hydroxy Vitamin D Detection Kit is a versatile tool in clinical practice, aiding in the diagnosis and management of various health conditions. Its ability to provide accurate and rapid results makes it a valuable asset in healthcare settings.

Purchasing Guide

When purchasing the 25-Hydroxy Vitamin D Detection Kit, consider factors such as product specifications, types, budget, and intended use to ensure the best fit for your clinical needs.

1. Product specifications: Evaluate the kit's sensitivity, specificity, and compatibility with your laboratory equipment to ensure accurate results.
2. Product types: Choose from various packaging sizes and configurations to match your testing volume and requirements.
3. Budget: Consider the cost-effectiveness of the kit, including the price per test and the overall value it provides.
4. Usage scenarios: Assess the kit's suitability for different clinical settings, such as hospitals, clinics, or research laboratories, to ensure it meets your specific needs.

Selecting the right 25-Hydroxy Vitamin D Detection Kit involves careful consideration of various factors. By evaluating product specifications, types, budget, and usage scenarios, you can make an informed decision that best suits your clinical requirements.

 Precautions

Proper handling and storage of the 25-Hydroxy Vitamin D Detection Kit are essential to ensure accurate results and maintain the integrity of the components.

1. Storage conditions: Store the kit at the recommended temperature to prevent degradation of the reagents and ensure consistent performance.
2. Handling procedures: Follow the instructions carefully when handling the detection cards and sample processing solution to avoid contamination or damage.
3. Expiration dates: Always check the expiration date before use to ensure the kit's components are still effective.
4. Safety measures: Wear appropriate protective gear, such as gloves and lab coats, when handling the kit to prevent exposure to hazardous materials.
5. Disposal: Dispose of used components according to local regulations to ensure environmental safety and compliance.

Taking proper precautions when using the 25-Hydroxy Vitamin D Detection Kit is crucial for obtaining accurate results and ensuring safety. By following storage, handling, and disposal guidelines, you can maintain the kit's effectiveness and protect both yourself and the environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files