The ARCHITECT 25-OH Vitamin D Calibrators are essential tools for laboratories aiming to achieve precise measurements of 25-hydroxy vitamin D levels in human serum and plasma. These calibrators are formulated with high-quality components, including heat-inactivated horse serum and phosphate-buffered saline, ensuring consistency and reliability in diagnostic testing.
1. The calibrators are characterized by their high stability and precision, making them ideal for use in clinical laboratories. They are designed to provide consistent results across different batches and over extended periods.
2. The composition includes phosphate-buffered saline (PBS) with heat-inactivated horse serum, which mimics the biological matrix of human serum. Calibrators B-F also contain 25-hydroxy vitamin D, allowing for accurate calibration of assays.
3. These calibrators are specifically used for the calibration of 25-hydroxy vitamin D assays in human serum and plasma. They ensure that diagnostic tests provide accurate and reliable results, which are crucial for patient care and treatment decisions.
The ARCHITECT 25-OH Vitamin D Calibrators, also known as 25-OH Vitamin D Standards, are indispensable in clinical laboratories. Their precise formulation and reliable performance make them a trusted choice for calibrating 25-hydroxy vitamin D assays, ensuring that healthcare providers can make informed decisions based on accurate diagnostic data.
The main features of the ARCHITECT 25-OH Vitamin D Calibrators include high stability, precision, and compatibility with various diagnostic platforms. These features ensure reliable and consistent calibration of 25-hydroxy vitamin D assays.
1. High Stability: The calibrators are formulated with preservatives like ProClin 300 and ProClin 950, ensuring long-term stability and reducing the need for frequent recalibration.
2. Precision: The inclusion of 25-hydroxy vitamin D in calibrators B-F allows for precise calibration, minimizing variability in assay results.
3. Compatibility: These calibrators are compatible with a wide range of diagnostic platforms, making them versatile tools in clinical laboratories.
4. Consistency: The use of heat-inactivated horse serum in the calibrators ensures that they mimic the biological matrix of human serum, providing consistent results across different batches.
5. Ease of Use: The calibrators are designed for easy integration into laboratory workflows, reducing the time and effort required for calibration.
The ARCHITECT 25-OH Vitamin D Calibrators stand out for their stability, precision, and ease of use. These features make them an essential component in any laboratory focused on accurate 25-hydroxy vitamin D testing, ensuring that results are reliable and consistent.
The ARCHITECT 25-OH Vitamin D Calibrators are widely used in clinical settings to ensure the accuracy of 25-hydroxy vitamin D assays. They are essential for diagnosing and monitoring vitamin D deficiency and related conditions.
1. Diagnosis of Vitamin D Deficiency: These calibrators are crucial for accurately measuring 25-hydroxy vitamin D levels, which is essential for diagnosing vitamin D deficiency.
2. Monitoring Treatment: Accurate calibration ensures that changes in vitamin D levels can be reliably monitored during treatment, allowing for adjustments in therapy as needed.
3. Research Applications: The calibrators are also used in research settings to study the role of vitamin D in various health conditions, providing reliable data for scientific studies.
4. Quality Control: Laboratories use these calibrators as part of their quality control processes, ensuring that all diagnostic tests meet the required standards of accuracy and precision.
5. Clinical Trials: In clinical trials, these calibrators are used to ensure that vitamin D levels are measured consistently across different study sites, providing reliable data for analysis.
The ARCHITECT 25-OH Vitamin D Calibrators play a vital role in clinical diagnostics, research, and quality control. Their ability to provide accurate and consistent calibration ensures that healthcare providers can rely on the results of 25-hydroxy vitamin D assays, ultimately improving patient care.
When purchasing the ARCHITECT 25-OH Vitamin D Calibrators, it is important to consider factors such as product specifications, types, budget, and intended use to ensure that the calibrators meet the laboratory's needs.
1. Product Specifications: Review the technical specifications of the calibrators, including their composition, stability, and compatibility with diagnostic platforms, to ensure they meet your laboratory's requirements.
2. Product Types: Choose the appropriate type of calibrator based on your laboratory's needs. Consider whether you require calibrators with or without 25-hydroxy vitamin D, depending on your assay requirements.
3. Budget: Determine your budget for calibration products and compare prices from different suppliers to ensure you are getting the best value for your investment.
4. Usage Scenarios: Consider the specific scenarios in which the calibrators will be used, such as routine diagnostics, research, or clinical trials, to ensure that the product is suitable for your intended applications.
Purchasing the ARCHITECT 25-OH Vitamin D Calibrators requires careful consideration of product specifications, types, budget, and usage scenarios. By taking these factors into account, laboratories can ensure that they select the right calibrators to meet their needs and achieve accurate and reliable results.
When using the ARCHITECT 25-OH Vitamin D Calibrators, it is important to follow proper handling and storage procedures to ensure the integrity and accuracy of the calibrators.
1. Storage Conditions: Store the calibrators at the recommended temperature to maintain their stability and prevent degradation. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling: Handle the calibrators with care to avoid contamination. Use sterile techniques when preparing and using the calibrators to ensure accurate results.
3. Expiration Date: Always check the expiration date before use. Do not use expired calibrators, as they may not provide accurate results.
4. Compatibility: Ensure that the calibrators are compatible with your diagnostic platform before use. Incompatibility can lead to inaccurate calibration and unreliable results.
5. Documentation: Keep detailed records of calibration procedures and results. This documentation is essential for quality control and troubleshooting.
Proper handling and storage of the ARCHITECT 25-OH Vitamin D Calibrators are crucial for maintaining their integrity and ensuring accurate results. By following the recommended precautions, laboratories can maximize the performance of these calibrators and achieve reliable diagnostic outcomes.