Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine
The Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine is composed of an LDX-20 slit lamp microscope with an electric light source, an Nd:YAG Q-switched laser with its power supply, a semiconductor aiming laser with its power supply, and a controller. The system is designed for precise ophthalmic procedures, ensuring high accuracy and safety.
Product English Name:
Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine
Alias:
YAG Laser System,Ophthalmic Laser Therapy Device
Intended Use:
This device is clinically used for treating conditions such as membranous cataracts, capsulotomy, iridotomy, and vitreous strand cutting. It provides a non-invasive solution for various eye disorders, enhancing patient outcomes with minimal discomfort.
Product Introduction

The Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine is a state-of-the-art medical device designed for precise and effective treatment of various eye conditions. It combines advanced laser technology with user-friendly controls, making it a reliable tool for ophthalmologists. The machine is equipped with a high-precision aiming system and multiple pulse modes, ensuring optimal treatment outcomes.

1. The Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine features a compact and ergonomic design, making it easy to operate in clinical settings. Its advanced laser technology ensures high precision and safety during procedures.
2. The machine is composed of an LDX-20 slit lamp microscope, an Nd:YAG Q-switched laser, a semiconductor aiming laser, and a controller. Each component is meticulously designed to work in harmony, providing a seamless treatment experience.
3. This device is used for various ophthalmic procedures, including capsulotomy, iridotomy, and vitreous strand cutting. Its versatility and precision make it an essential tool in modern ophthalmology.

The Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine, also known as the YAG Laser System, is a versatile and reliable device for treating a range of eye conditions. Its advanced features and user-friendly design make it a valuable asset in any ophthalmic practice.

Main Features

The Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine offers high precision, multiple pulse modes, and a user-friendly interface, making it ideal for various ophthalmic procedures.

1. The machine features a high-precision aiming system, ensuring accurate targeting during procedures. This reduces the risk of complications and enhances patient safety.
2. It offers multiple pulse modes, including single, double, and triple pulses, allowing for customized treatment based on the patient's condition.
3. The device is equipped with a compact and ergonomic design, making it easy to operate and integrate into clinical settings.
4. The Nd:YAG laser provides a wavelength of 1.064μm±5nm, ensuring effective treatment with minimal tissue damage.
5. The machine includes a semiconductor aiming laser with a wavelength of 635~650nm, providing clear visualization of the treatment area.

The Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine stands out for its precision, versatility, and ease of use. Its advanced features make it a top choice for ophthalmologists seeking reliable and effective treatment solutions.

Clinical Applications

The Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine is widely used in clinical settings for treating conditions such as cataracts, capsulotomy, and iridotomy, providing effective and minimally invasive solutions.

1. The device is commonly used for capsulotomy, a procedure to treat posterior capsule opacification after cataract surgery. Its precision ensures minimal damage to surrounding tissues.
2. It is also used for iridotomy, a procedure to create a small hole in the iris to treat conditions like angle-closure glaucoma. The machine's accuracy ensures successful outcomes.
3. The machine is effective in treating membranous cataracts, providing a non-invasive solution that improves patient vision.
4. It is used for vitreous strand cutting, a procedure to remove fibrous strands in the vitreous humor, enhancing visual clarity.
5. The device is also employed in other ophthalmic procedures, such as laser trabeculoplasty, offering a versatile solution for various eye conditions.

The Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine is a versatile tool in ophthalmology, offering effective and minimally invasive solutions for a range of eye conditions. Its precision and reliability make it a trusted choice for clinicians.

Purchasing Guide

When purchasing the Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical needs.

1. Product specifications: Ensure the machine meets the required performance standards, including laser wavelength, pulse width, and energy output.
2. Product types: Choose between different models based on your clinic's requirements, such as portability, additional features, and compatibility with other devices.
3. Budget: Consider the total cost of ownership, including maintenance, training, and potential upgrades, to ensure it fits within your budget.
4. Usage scenarios: Evaluate the machine's suitability for your clinic's specific procedures and patient volume to ensure it meets your clinical needs.

Purchasing the Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine requires careful consideration of various factors, including specifications, types, budget, and usage scenarios. By doing so, you can ensure it meets your clinic's needs and provides optimal patient care.

 Precautions

When using the Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine, it is essential to follow safety protocols, ensure proper maintenance, and provide adequate training to operators to prevent complications.

1. Always wear appropriate laser safety glasses to protect your eyes from accidental exposure to the laser beam.
2. Ensure the machine is properly calibrated and maintained to prevent malfunctions and ensure accurate treatment.
3. Provide comprehensive training to operators to ensure they are familiar with the machine's functions and safety protocols.
4. Follow the manufacturer's guidelines for usage and maintenance to prolong the machine's lifespan and ensure optimal performance.
5. Regularly inspect the machine for any signs of wear or damage and address any issues promptly to prevent complications during procedures.

Using the Nd:YAG Q-Switched Laser Ophthalmic Treatment Machine requires adherence to safety protocols, proper maintenance, and operator training. By following these precautions, you can ensure safe and effective treatment outcomes for your patients.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files