Nd:YAG Frequency-Doubled Laser Therapy System GreenLight XPS
The therapy system consists of a main unit, a light guide system, and a foot switch. The main unit includes a laser generator, laser power supply and control device, safety protection system, and cooling system. The light guide system comprises a fiber optic transmission system and an aiming light device. The fiber optic model is 0010-2400, sterilized with ethylene oxide, and has a shelf life of two years.
Product English Name:
Nd:YAG Frequency-Doubled Laser Therapy System GreenLight XPS
Alias:
GreenLight Laser System,XPS Laser Therapy Device
Intended Use:
This product is used to perform vaporization of prostate tissue in male patients with benign prostatic hyperplasia (BPH).
Product Introduction

The Nd:YAG Frequency-Doubled Laser Therapy System, also known as the GreenLight XPS Laser System, is a state-of-the-art medical device designed for the treatment of benign prostatic hyperplasia (BPH). It utilizes a high-powered laser to vaporize excess prostate tissue, providing a minimally invasive solution for patients suffering from BPH. The system is known for its precision, safety, and effectiveness, making it a preferred choice among urologists worldwide.

1. The GreenLight XPS Laser System is characterized by its advanced laser technology, which allows for precise tissue ablation with minimal damage to surrounding areas. The system's high-powered laser ensures quick and efficient vaporization of prostate tissue, reducing procedure time and patient discomfort.
2. The system is composed of a main unit, which houses the laser generator, power supply, and control mechanisms, along with a cooling system to maintain optimal operating temperatures. The light guide system, including the fiber optic transmission and aiming light, ensures accurate delivery of the laser beam to the target tissue.
3. The primary use of the GreenLight XPS Laser System is in the treatment of benign prostatic hyperplasia (BPH). It is particularly effective in reducing the symptoms associated with BPH, such as difficulty in urination, frequent urination, and incomplete bladder emptying. The system's minimally invasive approach results in quicker recovery times and fewer complications compared to traditional surgical methods.

The GreenLight XPS Laser System, with its advanced Nd:YAG laser technology, offers a highly effective and minimally invasive solution for treating benign prostatic hyperplasia. Its precision and safety make it a trusted tool in urology, providing significant relief to patients suffering from BPH.

Main Features

The GreenLight XPS Laser System is renowned for its high-powered laser, precision targeting, and efficient tissue vaporization capabilities. It is designed to provide a safe and effective treatment for benign prostatic hyperplasia (BPH).

1. The system features a high-powered Nd:YAG laser that delivers precise energy to the prostate tissue, ensuring effective vaporization with minimal collateral damage.
2. The integrated cooling system maintains the laser at optimal temperatures, enhancing performance and prolonging the lifespan of the device.
3. The light guide system, including the fiber optic transmission and aiming light, ensures accurate delivery of the laser beam, allowing for precise targeting of the prostate tissue.
4. The system's safety mechanisms, including automatic shut-off and real-time monitoring, ensure patient safety throughout the procedure.
5. The GreenLight XPS Laser System is designed for ease of use, with a user-friendly interface and ergonomic foot switch, allowing for smooth operation during procedures.

The GreenLight XPS Laser System stands out for its advanced laser technology, precision, and safety features. It is a reliable and efficient tool for urologists, offering significant benefits in the treatment of benign prostatic hyperplasia.

Clinical Applications

The GreenLight XPS Laser System is widely used in clinical settings for the treatment of benign prostatic hyperplasia (BPH). It is particularly effective in reducing symptoms and improving the quality of life for patients.

1. The system is used in urology clinics and hospitals for the vaporization of prostate tissue in patients with BPH, providing a minimally invasive alternative to traditional surgery.
2. It is particularly effective in treating patients with large prostates, where traditional surgical methods may be less effective or carry higher risks.
3. The GreenLight XPS Laser System is also used in cases where patients have comorbidities that make them unsuitable for conventional surgical procedures.
4. The system's precision and safety make it a preferred choice for treating BPH in elderly patients, who may be at higher risk for complications from traditional surgery.
5. The GreenLight XPS Laser System is increasingly being used in outpatient settings, allowing for quicker recovery times and reduced hospital stays.

The GreenLight XPS Laser System has become a cornerstone in the clinical treatment of benign prostatic hyperplasia. Its minimally invasive approach, combined with its precision and safety, makes it an invaluable tool in urology, significantly improving patient outcomes.

Purchasing Guide

When purchasing the GreenLight XPS Laser System, it is important to consider factors such as product specifications, types, budget, and intended use to ensure the best fit for your clinical needs.

1. Product specifications, including laser power, fiber optic type, and cooling system efficiency, should be carefully evaluated to ensure the system meets your clinical requirements.
2. Consider the different types of laser systems available, such as those with varying power outputs or additional safety features, to find the one that best suits your practice.
3. Budget considerations are crucial, as the cost of the system, along with maintenance and operational expenses, should align with your financial planning.
4. The intended use of the system, whether for high-volume clinics or specialized urology centers, should guide your purchasing decision to ensure optimal performance and patient outcomes.

Purchasing the GreenLight XPS Laser System requires careful consideration of various factors, including product specifications, types, budget, and intended use. By taking these into account, you can ensure that the system you choose will meet your clinical needs and provide the best possible outcomes for your patients.

 Precautions

When using the GreenLight XPS Laser System, it is essential to follow safety protocols and guidelines to ensure the safety of both patients and medical staff.

1. Always ensure that the laser system is properly calibrated and maintained to prevent malfunctions during procedures.
2. Use appropriate laser safety glasses to protect the eyes from harmful laser radiation during operation.
3. Follow strict sterilization protocols for the fiber optic cables and other components to prevent infections.
4. Monitor the cooling system closely to prevent overheating, which could damage the laser and compromise patient safety.
5. Train all medical staff thoroughly on the operation of the GreenLight XPS Laser System to ensure safe and effective use.

The GreenLight XPS Laser System, while highly effective, requires careful handling and adherence to safety protocols. By following these precautions, medical staff can ensure the safe and successful use of the system, providing the best possible care for their patients.