Nd:YAG Frequency-Doubled Laser Therapy System GreenLight XPS
The GreenLight XPS Laser System is composed of a main unit, a light guide system, and a footswitch. The main unit includes a laser generator, laser power supply and control device, safety protection system, and cooling system. The light guide system consists of a fiber optic transmission system and an aiming light device. The system operates at a laser wavelength of 532nm ± 5nm, with a terminal output power ranging from 20-180W (±5% error). The aiming light operates at 635nm ± 10nm with an output power of ≤5mW. The disposable sterile quartz fiber has a core diameter of 750μm ± 10% and a spot diameter of ≤1.95mm.
Product English Name:
Nd:YAG Frequency-Doubled Laser Therapy System GreenLight XPS
Alias:
GreenLight Laser System,XPS Laser Therapy Device
Intended Use:
This product is designed for the vaporization of prostate tissue in male patients suffering from benign prostatic hyperplasia (BPH). It provides a minimally invasive treatment option, reducing recovery time and improving patient outcomes.
Product Introduction

The GreenLight XPS Laser System is a state-of-the-art medical device designed for the treatment of benign prostatic hyperplasia (BPH). Utilizing Nd:YAG frequency-doubled laser technology, it offers precise and efficient tissue vaporization with minimal side effects. The system is known for its reliability, ease of use, and advanced safety features, making it a preferred choice for urologists worldwide.

1. The GreenLight XPS Laser System is characterized by its high precision and efficiency in tissue vaporization. The 532nm wavelength ensures optimal absorption by hemoglobin, leading to effective tissue removal with minimal thermal damage to surrounding areas.
2. The system's structure includes a robust main unit housing the laser generator, power supply, and cooling mechanisms. The light guide system, featuring a high-quality fiber optic transmission, ensures accurate delivery of laser energy to the target tissue.
3. Primarily used for treating BPH, the GreenLight XPS Laser System offers a minimally invasive alternative to traditional surgical methods. It reduces hospital stays, lowers the risk of complications, and provides quicker recovery times for patients.

The GreenLight XPS Laser System, also known as the Nd:YAG Frequency-Doubled Laser Therapy System, is a cutting-edge solution for BPH treatment. Its advanced technology and user-friendly design make it a reliable tool for urologists, ensuring effective and safe patient care.

Main Features

The GreenLight XPS Laser System excels in delivering precise laser energy for tissue vaporization, offering a minimally invasive treatment option for BPH. Its advanced cooling and safety systems ensure reliable performance during procedures.

1. The system's 532nm laser wavelength is highly effective for tissue vaporization, ensuring minimal damage to surrounding tissues.
2. The integrated cooling system maintains optimal operating temperatures, enhancing the device's longevity and performance.
3. The fiber optic transmission system provides accurate and consistent delivery of laser energy, crucial for effective treatment.
4. The system's safety features, including real-time monitoring and automatic shutdown mechanisms, ensure patient and operator safety.
5. The user-friendly interface and ergonomic design make the system easy to operate, reducing the learning curve for medical professionals.

The GreenLight XPS Laser System stands out for its precision, safety, and ease of use. Its advanced features make it an indispensable tool for urologists, ensuring effective treatment outcomes for patients with BPH.

Clinical Applications

The GreenLight XPS Laser System is widely used in clinical settings for the treatment of benign prostatic hyperplasia (BPH). Its minimally invasive approach reduces patient recovery time and improves overall treatment outcomes.

1. The system is primarily used for prostate tissue vaporization in patients with BPH, offering a less invasive alternative to traditional surgery.
2. It is particularly effective for patients with larger prostates, where traditional methods may be less efficient.
3. The system's precision reduces the risk of complications such as bleeding and infection, common in traditional surgical procedures.
4. It is also used in cases where patients have comorbidities that make them unsuitable for conventional surgery.
5. The quick recovery time associated with the GreenLight XPS Laser System allows patients to return to normal activities sooner, improving their quality of life.

The GreenLight XPS Laser System has revolutionized the treatment of BPH, offering a safer and more efficient alternative to traditional surgical methods. Its clinical applications continue to expand, benefiting both patients and healthcare providers.

Purchasing Guide

When purchasing the GreenLight XPS Laser System, consider factors such as product specifications, budget, and intended use to ensure it meets your clinical needs.

1. Evaluate the product's technical specifications, including laser wavelength, output power, and cooling system efficiency, to ensure it aligns with your clinical requirements.
2. Consider the types of procedures you intend to perform and choose a system that offers the necessary features and flexibility.
3. Establish a budget that accounts for both the initial purchase and ongoing maintenance costs, ensuring long-term affordability.
4. Assess the system's compatibility with your existing medical infrastructure and its ease of integration into your clinical workflow.

Purchasing the GreenLight XPS Laser System requires careful consideration of technical specifications, budget, and clinical needs. By doing so, you can ensure that the system will effectively meet your requirements and provide long-term value.

 Precautions

Proper handling and maintenance of the GreenLight XPS Laser System are crucial to ensure its safe and effective operation. Adhering to safety protocols and regular maintenance schedules can prevent potential issues.

1. Always wear appropriate laser safety glasses to protect your eyes from accidental exposure to laser beams.
2. Regularly inspect the fiber optic cables for signs of wear or damage, replacing them as necessary to maintain optimal performance.
3. Ensure the cooling system is functioning correctly to prevent overheating, which could damage the laser components.
4. Follow the manufacturer's guidelines for cleaning and sterilizing the system to avoid contamination and ensure patient safety.
5. Train all operators on the proper use of the system, including emergency shutdown procedures, to minimize the risk of accidents.

The GreenLight XPS Laser System requires diligent care and attention to ensure its safe and effective use. By following proper precautions and maintenance routines, you can maximize the system's performance and longevity, ensuring the best outcomes for your patients.