The 25-Hydroxy Vitamin D Assay Kit is a state-of-the-art diagnostic tool designed to measure the levels of 25-OH-VD in human blood samples. Utilizing fluorescence immunochromatography, this kit offers high sensitivity and specificity, making it an essential tool for clinicians and researchers. The kit is composed of several components, including a detection card, parameter card, sample buffer, and sample tube, each meticulously designed to ensure accurate and reliable results.
1. The detection card is a critical component of the kit, featuring a sample pad, nitrocellulose membrane, absorbent paper, and backing. The nitrocellulose membrane is coated with a synthetic Vitamin D antigen, and fluorescent microspheres are labeled with 25-OH-VD monoclonal antibodies, ensuring precise detection.
2. The sample buffer, a phosphate buffer containing guanidine thiocyanate, SDS, and EDTA, is available in various packaging sizes to accommodate different testing needs. This buffer plays a crucial role in sample preparation, ensuring that the sample is properly diluted and stabilized for accurate measurement.
3. The kit is primarily used for the quantitative determination of 25-Hydroxy Vitamin D in human serum, plasma, or whole blood. It is an invaluable tool in clinical settings, aiding in the diagnosis of Vitamin D deficiency-related diseases and helping healthcare providers make informed treatment decisions.
The 25-Hydroxy Vitamin D Assay Kit, also known as the Vitamin D Test Kit, is a comprehensive diagnostic tool designed to measure Vitamin D levels accurately. Its components, including the detection card and sample buffer, are engineered for precision and reliability. This kit is indispensable in clinical settings, providing critical data for the diagnosis and management of Vitamin D deficiency-related conditions.
The 25-Hydroxy Vitamin D Assay Kit offers high sensitivity and specificity, utilizing fluorescence immunochromatography for accurate measurement of Vitamin D levels. Its components are designed for ease of use and reliability, making it a preferred choice for clinical diagnostics.
1. High Sensitivity: The kit's fluorescence immunochromatography technology ensures high sensitivity, allowing for the detection of even low levels of 25-OH-VD in blood samples.
2. Specificity: The use of synthetic Vitamin D antigen and 25-OH-VD monoclonal antibodies ensures high specificity, reducing the risk of cross-reactivity with other substances.
3. Ease of Use: The kit's components, including the detection card and sample buffer, are designed for straightforward sample preparation and testing, minimizing the potential for user error.
4. Reliability: The kit's components are manufactured under strict quality control standards, ensuring consistent and reliable results across different batches.
5. Versatility: The kit is compatible with various sample types, including serum, plasma, and whole blood, making it a versatile tool for different clinical settings.
The 25-Hydroxy Vitamin D Assay Kit stands out for its high sensitivity, specificity, and ease of use. Its components are designed to provide reliable and accurate results, making it an essential tool for clinicians. Whether used in research or clinical diagnostics, this kit offers unparalleled performance and versatility.
The 25-Hydroxy Vitamin D Assay Kit is widely used in clinical settings for the diagnosis and management of Vitamin D deficiency-related diseases. Its high sensitivity and specificity make it a valuable tool for healthcare providers.
1. Diagnosis of Vitamin D Deficiency: The kit is primarily used to diagnose Vitamin D deficiency, a condition that can lead to various health issues, including osteoporosis and rickets.
2. Monitoring Vitamin D Levels: Healthcare providers use the kit to monitor Vitamin D levels in patients undergoing treatment for Vitamin D deficiency, ensuring that treatment is effective.
3. Research Applications: The kit is also used in research settings to study the role of Vitamin D in various diseases and conditions, providing valuable data for scientific studies.
4. Pediatric Care: The kit is particularly useful in pediatric care, where Vitamin D deficiency can have significant impacts on growth and development.
5. Geriatric Care: In geriatric care, the kit is used to monitor Vitamin D levels in elderly patients, who are at higher risk for Vitamin D deficiency due to reduced sun exposure and dietary intake.
The 25-Hydroxy Vitamin D Assay Kit is a versatile tool in clinical settings, used for diagnosing and monitoring Vitamin D deficiency. Its applications extend to pediatric and geriatric care, as well as research, making it an indispensable resource for healthcare providers and researchers alike.
When purchasing the 25-Hydroxy Vitamin D Assay Kit, it is essential to consider product parameters, types, budget, and usage scenarios to ensure the kit meets your specific needs.
1. Product Parameters: Consider the kit's sensitivity, specificity, and compatibility with different sample types when making a purchase decision.
2. Product Types: The kit is available in various packaging sizes, including 1, 20, 25, and 50 tests per box. Choose the type that best suits your testing volume.
3. Budget: Evaluate your budget and the cost per test to ensure the kit is a cost-effective solution for your needs.
4. Usage Scenarios: Consider the specific clinical or research settings in which the kit will be used, ensuring it meets the requirements of your application.
Purchasing the 25-Hydroxy Vitamin D Assay Kit requires careful consideration of product parameters, types, budget, and usage scenarios. By evaluating these factors, you can ensure that the kit meets your specific needs and provides reliable and accurate results.
Proper handling and storage of the 25-Hydroxy Vitamin D Assay Kit are crucial to ensure accurate results and maintain the integrity of the components.
1. Storage Conditions: Store the kit at the recommended temperature to prevent degradation of the components, ensuring accurate and reliable results.
2. Handling: Handle the kit components with care, avoiding contamination and ensuring proper sample preparation to maintain the integrity of the test.
3. Expiration Date: Always check the expiration date before use, as expired components may yield inaccurate results.
4. Sample Collection: Ensure proper sample collection techniques are followed to avoid contamination and ensure accurate measurement of Vitamin D levels.
5. Disposal: Dispose of used components according to local regulations, ensuring safe and environmentally friendly disposal practices.
The 25-Hydroxy Vitamin D Assay Kit requires careful handling and storage to ensure accurate results. By following proper storage conditions, handling techniques, and disposal practices, you can maintain the integrity of the kit and achieve reliable outcomes in your clinical or research applications.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.