The N-Acetyl-β-D-Glucosaminidase Assay Kit is a specialized diagnostic tool used to measure the activity of the enzyme N-Acetyl-β-D-Glucosaminidase in biological samples. This enzyme is a key biomarker for renal health, and its levels can indicate early stages of kidney dysfunction. The kit employs a rate method, ensuring high sensitivity and accuracy in detecting enzyme activity.
1. The kit features a two-reagent system that ensures stability and reliability in enzyme activity measurement. The inclusion of a specific substrate, 6-Methyl-2-Mercaptopyridine-N-Acetyl-β-D-Glucosaminidase, allows for precise detection of the enzyme.
2. The composition of the kit includes Reagent 1 (R1) with a buffer solution and Reagent 2 (R2) containing both a buffer and the substrate. An optional calibrator is available to standardize measurements across different samples.
3. The primary use of this kit is in clinical settings for the quantitative determination of N-Acetyl-β-D-Glucosaminidase activity in human urine and serum. It is particularly useful in diagnosing early kidney damage and monitoring renal function.
The N-Acetyl-β-D-Glucosaminidase Assay Kit, also known as the NAG Assay Kit, is a vital tool in clinical diagnostics. Its unique composition and precise measurement capabilities make it indispensable for assessing renal health. Whether you're monitoring kidney function or detecting early signs of damage, this kit offers reliable and accurate results.
The N-Acetyl-β-D-Glucosaminidase Assay Kit offers high sensitivity and accuracy in measuring enzyme activity, making it a reliable tool for clinical diagnostics.
1. The kit utilizes a rate method, which ensures precise and consistent measurement of enzyme activity over time.
2. It includes a two-reagent system that enhances the stability and reliability of the assay, reducing the risk of errors.
3. The optional calibrator allows for standardization across different samples, ensuring accurate and comparable results.
4. The kit is designed for ease of use, with clear instructions and minimal preparation required, making it suitable for routine clinical use.
5. It provides rapid results, enabling timely diagnosis and monitoring of renal function, which is crucial for patient care.
The N-Acetyl-β-D-Glucosaminidase Assay Kit stands out for its precision, ease of use, and reliability. Its advanced features make it an essential tool for clinicians aiming to provide accurate and timely diagnoses, particularly in the context of renal health.
This kit is primarily used in clinical settings to assess renal function and detect early kidney damage through the measurement of N-Acetyl-β-D-Glucosaminidase activity.
1. In clinical diagnostics, the kit is used to monitor renal function in patients with suspected kidney disease, providing early detection of damage.
2. It is also employed in research settings to study the role of N-Acetyl-β-D-Glucosaminidase in various renal pathologies.
3. The kit is useful in monitoring the effectiveness of treatments for kidney diseases, allowing clinicians to adjust therapies as needed.
4. It is used in epidemiological studies to assess the prevalence of kidney damage in specific populations.
5. The kit is also applied in toxicology studies to evaluate the impact of nephrotoxic substances on renal health.
The N-Acetyl-β-D-Glucosaminidase Assay Kit is a versatile tool in both clinical and research settings. Its ability to provide accurate and timely measurements of enzyme activity makes it invaluable for diagnosing and monitoring renal health, as well as for advancing our understanding of kidney diseases.
When purchasing the N-Acetyl-β-D-Glucosaminidase Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical needs.
1. Product specifications: Ensure the kit includes all necessary components, such as Reagent 1, Reagent 2, and the optional calibrator, and verify the shelf life and storage conditions.
2. Product types: Choose between different kit sizes or configurations based on your laboratory's volume of testing and specific requirements.
3. Budget: Consider the cost per test and the overall budget for your laboratory, balancing quality and affordability.
4. Usage scenarios: Evaluate the kit's suitability for your intended applications, such as routine clinical diagnostics or research studies, to ensure it meets your needs.
Purchasing the N-Acetyl-β-D-Glucosaminidase Assay Kit requires careful consideration of various factors, including product specifications, types, budget, and intended use. By taking these into account, you can ensure that the kit you choose will effectively meet your clinical and research needs.
Proper handling and storage of the N-Acetyl-β-D-Glucosaminidase Assay Kit are essential to ensure accurate results and maintain the integrity of the reagents.
1. Always follow the manufacturer's instructions for storage and handling to prevent degradation of the reagents.
2. Ensure that all components are stored at the recommended temperature and protected from light to maintain their stability.
3. Use appropriate personal protective equipment (PPE) when handling the kit to avoid contamination and ensure safety.
4. Regularly check the expiration dates of the reagents and calibrators to ensure they are within the valid period for use.
5. Perform regular quality control checks to verify the accuracy and reliability of the assay results.
The N-Acetyl-β-D-Glucosaminidase Assay Kit requires careful handling and storage to ensure optimal performance. By adhering to the recommended precautions, you can maintain the integrity of the reagents and achieve accurate and reliable results in your clinical diagnostics.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.