Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
25-Hydroxy Vitamin D (25-OH-VD) Assay Kit (Fluorescence Immunochromatography)
The kit primarily consists of a test card, sample buffer, calibration curve card, and optional quality control materials. The test card includes a card shell and a detection strip, which comprises a sample pad, conjugate pad (with fluorescent microsphere-labeled mouse anti-human 25-OH-VD monoclonal antibody and fluorescent microsphere-labeled chicken IgY polyclonal antibody), nitrocellulose membrane (with 25-OH-VD coated in the test line and goat anti-chicken IgY antibody in the control line), absorbent pad, and backing card. The sample buffer is a phosphate-buffered saline (PBS) solution. The optional quality control materials include 25-hydroxy vitamin D and ProClin300, with specific concentrations indicated on the bottle label.
Product English Name:
25-Hydroxy Vitamin D (25-OH-VD) Assay Kit (Fluorescence Immunochromatography)
Alias:
25-OH-VD Test Kit,Vitamin D Assay Kit
Intended Use:
This kit is designed for the quantitative determination of 25-hydroxy vitamin D (25-OH-VD) levels in human serum, plasma, or whole blood. It is clinically used for the auxiliary diagnosis of diseases related to vitamin D deficiency, such as rickets, osteoporosis, and other metabolic bone disorders.
Product Introduction

The 25-Hydroxy Vitamin D Assay Kit is a state-of-the-art diagnostic tool designed for the accurate and rapid measurement of 25-OH-VD levels in human samples. Utilizing fluorescence immunochromatography, this kit offers high sensitivity and specificity, making it an essential tool in clinical laboratories for assessing vitamin D status. The kit is user-friendly, with a straightforward procedure that ensures reliable results within a short time frame.

1. The kit features a unique test card design that integrates multiple components, including a sample pad, conjugate pad, nitrocellulose membrane, and absorbent pad. This design ensures efficient sample flow and precise detection of 25-OH-VD levels.
2. The composition of the kit includes a sample buffer made of phosphate-buffered saline (PBS), which stabilizes the sample and enhances the accuracy of the assay. The optional quality control materials provide additional assurance of the kit's performance.
3. The primary use of this kit is to measure 25-OH-VD levels in human serum, plasma, or whole blood. It is particularly valuable in diagnosing and monitoring conditions related to vitamin D deficiency, such as osteoporosis and rickets.

The 25-Hydroxy Vitamin D Assay Kit, also known as the Vitamin D Assay Kit, is a reliable and efficient tool for measuring vitamin D levels in clinical settings. Its innovative design and high accuracy make it a preferred choice for healthcare professionals. The kit's components, including the test card and sample buffer, work together to provide precise and consistent results, aiding in the diagnosis and management of vitamin D-related disorders.

Main Features

The 25-Hydroxy Vitamin D Assay Kit offers high sensitivity and specificity, enabling accurate measurement of 25-OH-VD levels in human samples. Its user-friendly design and rapid results make it an essential tool in clinical diagnostics.

1. The kit utilizes fluorescence immunochromatography, which provides high sensitivity and specificity in detecting 25-OH-VD levels.
2. The test card is designed for easy handling, with a clear layout of components that ensure efficient sample flow and accurate results.
3. The sample buffer, made of phosphate-buffered saline (PBS), stabilizes the sample and enhances the accuracy of the assay.
4. The optional quality control materials, including 25-hydroxy vitamin D and ProClin300, provide additional assurance of the kit's performance and reliability.
5. The kit is designed for use in clinical laboratories, offering rapid and reliable results that aid in the diagnosis and monitoring of vitamin D-related disorders.

The 25-Hydroxy Vitamin D Assay Kit stands out for its high sensitivity, specificity, and user-friendly design. Its ability to provide rapid and accurate results makes it an indispensable tool in clinical diagnostics, particularly for assessing vitamin D status and managing related disorders.

Clinical Applications

The 25-Hydroxy Vitamin D Assay Kit is widely used in clinical settings for the diagnosis and monitoring of vitamin D deficiency-related disorders, such as osteoporosis and rickets.

1. The kit is used to measure 25-OH-VD levels in human serum, plasma, or whole blood, providing valuable information for the diagnosis of vitamin D deficiency.
2. It is particularly useful in monitoring patients with osteoporosis, as vitamin D plays a crucial role in bone health.
3. The kit is also employed in the diagnosis of rickets, a condition caused by severe vitamin D deficiency in children.
4. In addition to these applications, the kit is used in research settings to study the role of vitamin D in various metabolic processes.
5. The kit's high sensitivity and specificity make it a reliable tool for assessing vitamin D status in both clinical and research settings.

The 25-Hydroxy Vitamin D Assay Kit is a versatile tool in clinical diagnostics, particularly for the diagnosis and monitoring of vitamin D deficiency-related disorders. Its high sensitivity and specificity make it a reliable choice for healthcare professionals and researchers alike.

Purchasing Guide

When purchasing the 25-Hydroxy Vitamin D Assay Kit, it is important to consider factors such as product specifications, types, budget, and intended use to ensure the best fit for your clinical or research needs.

1. Product specifications: Ensure that the kit meets your laboratory's requirements in terms of sensitivity, specificity, and sample type compatibility.
2. Product types: Choose between different versions of the kit, such as those with or without quality control materials, based on your specific needs.
3. Budget: Consider the cost of the kit, including any additional expenses for quality control materials or accessories.
4. Intended use: Determine whether the kit will be used for clinical diagnostics, research, or both, and select the appropriate version accordingly.

Purchasing the 25-Hydroxy Vitamin D Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that the kit meets your clinical or research needs and provides reliable results.

 Precautions

When using the 25-Hydroxy Vitamin D Assay Kit, it is important to follow the manufacturer's instructions carefully to ensure accurate and reliable results. Proper handling and storage of the kit components are also crucial.

1. Always follow the manufacturer's instructions for sample preparation and assay procedure to avoid errors.
2. Store the kit components at the recommended temperature to maintain their stability and performance.
3. Use the optional quality control materials to verify the accuracy of the assay results.
4. Avoid cross-contamination by using clean and sterile equipment when handling samples.
5. Dispose of used materials according to local regulations and guidelines to ensure safety and environmental compliance.

Using the 25-Hydroxy Vitamin D Assay Kit requires careful attention to the manufacturer's instructions, proper storage, and handling of components. By following these precautions, you can ensure accurate and reliable results while maintaining safety and compliance with regulations.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files