Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
MJQ Pressure Steam Sterilizer
The MJQ Pressure Steam Sterilizer is composed of a control panel, sterilization chamber, and sealing door. During the sterilization process, the average temperature inside the chamber should be within 0-3°C of the preset temperature. The timing control error should be within ±10% of the preset value, and the steam pressure indication error should not exceed ±0.01MPa. The sterilizer offers two sterilization programs at 121°C and 135°C. The temperature of the operation handle should not exceed 60°C during sterilization. The product ensures effective sterilization and complies with the electrical safety requirements specified in Appendix A of the registered product standards.
Product English Name:
MJQ Pressure Steam Sterilizer
Alias:
Autoclave,Steam Sterilizer
Intended Use:
The MJQ Pressure Steam Sterilizer is designed for use in medical institutions, laboratories, and biomedical research units. It is used to sterilize instruments, dressings, glassware, injection equipment, and other items that can withstand high temperatures and steam.
Product Introduction

The MJQ Pressure Steam Sterilizer is a high-performance sterilization device widely used in medical and research settings. It ensures the complete elimination of microorganisms, providing a safe and sterile environment for medical procedures and experiments. The device is known for its reliability, precision, and user-friendly design, making it an essential tool in healthcare and scientific research.

1. The MJQ Pressure Steam Sterilizer is characterized by its robust construction and advanced control system. It features a durable sterilization chamber and a precise control panel that allows users to set and monitor sterilization parameters with ease.
2. The sterilizer is composed of a control panel, sterilization chamber, and sealing door. The control panel is equipped with a digital display and intuitive controls, while the sterilization chamber is designed to withstand high temperatures and pressures. The sealing door ensures a tight seal, preventing steam leakage during the sterilization process.
3. The MJQ Pressure Steam Sterilizer is used to sterilize a wide range of medical and laboratory equipment, including surgical instruments, dressings, glassware, and injection devices. It is particularly useful in settings where high levels of sterility are required, such as operating rooms, laboratories, and research facilities.

The MJQ Pressure Steam Sterilizer, also known as an autoclave or steam sterilizer, is a versatile and reliable device used in medical and research settings. Its robust construction, precise control system, and effective sterilization capabilities make it an indispensable tool for ensuring a sterile environment. Whether in a hospital, laboratory, or research facility, the MJQ Pressure Steam Sterilizer delivers consistent and reliable performance.

Main Features

The MJQ Pressure Steam Sterilizer offers a range of features designed to ensure effective and reliable sterilization. These include precise temperature and pressure control, user-friendly operation, and robust construction.

1. The sterilizer features a precise temperature control system that maintains the sterilization chamber within 0-3°C of the preset temperature, ensuring consistent and effective sterilization.
2. The device is equipped with a digital control panel that allows users to easily set and monitor sterilization parameters, including temperature, pressure, and cycle time.
3. The sterilization chamber is constructed from high-quality materials that can withstand high temperatures and pressures, ensuring long-lasting durability and reliability.
4. The sealing door is designed to provide a tight seal, preventing steam leakage and ensuring that the sterilization process is carried out efficiently and safely.
5. The MJQ Pressure Steam Sterilizer offers two sterilization programs at 121°C and 135°C, providing flexibility for different sterilization needs.

The MJQ Pressure Steam Sterilizer is a feature-rich device that combines precision, durability, and ease of use. Its advanced temperature and pressure control systems, along with its robust construction, make it a reliable choice for sterilization in medical and research settings. Whether you're sterilizing surgical instruments or laboratory glassware, the MJQ Pressure Steam Sterilizer delivers consistent and effective results.

Clinical Applications

The MJQ Pressure Steam Sterilizer is widely used in clinical settings for the sterilization of medical instruments and equipment. It is essential for maintaining a sterile environment in hospitals, clinics, and laboratories.

1. In operating rooms, the MJQ Pressure Steam Sterilizer is used to sterilize surgical instruments, ensuring that they are free from microorganisms before use in procedures.
2. In laboratories, the sterilizer is used to sterilize glassware, pipettes, and other equipment, preventing contamination of experiments and research samples.
3. In dental clinics, the device is used to sterilize dental instruments, ensuring patient safety and compliance with infection control standards.
4. In pharmaceutical manufacturing, the sterilizer is used to sterilize equipment and containers, ensuring the safety and efficacy of pharmaceutical products.
5. In research facilities, the MJQ Pressure Steam Sterilizer is used to sterilize equipment and materials used in biomedical research, ensuring the integrity of experimental results.

The MJQ Pressure Steam Sterilizer plays a critical role in maintaining a sterile environment in various clinical and research settings. Its ability to effectively sterilize a wide range of instruments and equipment makes it an essential tool in hospitals, laboratories, and research facilities. Whether in an operating room, laboratory, or dental clinic, the MJQ Pressure Steam Sterilizer ensures that medical procedures and experiments are conducted in a safe and sterile environment.

Purchasing Guide

When purchasing the MJQ Pressure Steam Sterilizer, it is important to consider factors such as product specifications, types, budget, and intended use. This guide provides an overview of key considerations to help you make an informed decision.

1. Product specifications: Consider the size of the sterilization chamber, temperature and pressure ranges, and cycle times to ensure that the sterilizer meets your specific needs.
2. Product types: The MJQ Pressure Steam Sterilizer is available in different models, including benchtop and floor-standing units. Choose the model that best fits your workspace and sterilization requirements.
3. Budget: Determine your budget and compare the features and specifications of different models to find the best value for your investment.
4. Intended use: Consider the types of instruments and equipment you will be sterilizing, as well as the volume of sterilization required, to select the most suitable model.

Purchasing the MJQ Pressure Steam Sterilizer requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can select the model that best meets your sterilization needs and ensures reliable performance in your clinical or research setting.

 Precautions

When using the MJQ Pressure Steam Sterilizer, it is important to follow safety guidelines and precautions to ensure effective and safe operation. This section outlines key precautions to consider.

1. Always ensure that the sterilization chamber is properly sealed before starting the sterilization cycle to prevent steam leakage and ensure effective sterilization.
2. Regularly inspect the sterilizer for signs of wear or damage, and perform routine maintenance to ensure optimal performance and longevity.
3. Follow the manufacturer's instructions for loading the sterilization chamber to avoid overloading, which can affect the effectiveness of the sterilization process.
4. Use only compatible sterilization accessories, such as sterilization pouches and trays, to ensure that the sterilization process is carried out effectively.
5. Monitor the sterilization cycle and check the indicators to confirm that the sterilization process has been completed successfully.

Using the MJQ Pressure Steam Sterilizer safely and effectively requires adherence to key precautions. By ensuring proper sealing, regular maintenance, and correct loading of the sterilization chamber, you can achieve consistent and reliable sterilization results. Always follow the manufacturer's guidelines and use compatible accessories to maintain the integrity of the sterilization process.