LM Series Medical Anti-Decubitus Air Mattress
The LM Series Medical Anti-Decubitus Air Mattress is primarily composed of an air mattress and an air pump (main unit). The air mattress has specific dimensions as listed in the registration form's attachment Table 1. Key performance indicators include a gas flow rate of at least 6L/min at the pump outlet, adjustable gas pressure of no less than 7kPa, and the ability to alternate air supply to odd and even-numbered air cells every 5 to 15 minutes. The mattress can withstand a maximum inflation pressure of at least 10kPa, operates with a noise level below 55dB(A), and supports a maximum uniform load of 135kg without damage or permanent deformation.
Product English Name:
LM Series Medical Anti-Decubitus Air Mattress
Alias:
Pressure Relief Mattress,Medical Air Cushion
Intended Use:
The LM Series Medical Anti-Decubitus Air Mattress is designed to prevent and treat pressure ulcers (bedsores) in patients who are bedridden or have limited mobility. It is commonly used in hospitals, nursing homes, and home care settings to provide continuous pressure relief and improve patient comfort.
Product Introduction

The LM Series Medical Anti-Decubitus Air Mattress is a high-quality medical device designed to prevent and treat pressure ulcers. It features an innovative alternating pressure system that redistributes pressure points, reducing the risk of bedsores. The mattress is durable, easy to clean, and suitable for long-term use in various healthcare settings.

1. The LM Series mattress is known for its alternating pressure system, which ensures that no single area of the body is under constant pressure, thereby reducing the risk of pressure ulcers.
2. The mattress is composed of high-quality materials, including a durable air mattress and a reliable air pump. The air cells are arranged in an alternating pattern to provide consistent pressure relief.
3. This mattress is primarily used in healthcare settings to prevent and treat pressure ulcers in patients who are bedridden or have limited mobility. It is also suitable for home care use.

The LM Series Medical Anti-Decubitus Air Mattress, also known as the Pressure Relief Mattress, is a reliable and effective solution for preventing and treating pressure ulcers. Its alternating pressure system and durable construction make it a valuable tool in both clinical and home care settings.

Main Features

The LM Series Medical Anti-Decubitus Air Mattress offers advanced features to prevent and treat pressure ulcers, including an alternating pressure system, adjustable settings, and durable construction.

1. The alternating pressure system ensures that pressure is evenly distributed across the mattress, reducing the risk of pressure ulcers.
2. The air pump allows for adjustable gas pressure and flow, providing customized comfort for patients.
3. The mattress is designed to withstand heavy loads without damage, making it suitable for a wide range of patients.
4. The low noise level of the air pump ensures a quiet environment, which is essential for patient comfort and recovery.
5. The mattress is easy to clean and maintain, making it ideal for long-term use in healthcare settings.

The LM Series Medical Anti-Decubitus Air Mattress is packed with features that make it an excellent choice for preventing and treating pressure ulcers. Its alternating pressure system, durability, and ease of use make it a valuable asset in any healthcare setting.

Clinical Applications

The LM Series Medical Anti-Decubitus Air Mattress is widely used in clinical settings to prevent and treat pressure ulcers in bedridden patients.

1. In hospitals, the mattress is used in intensive care units and long-term care wards to prevent pressure ulcers in critically ill patients.
2. Nursing homes use the mattress to provide comfort and prevent bedsores in elderly residents with limited mobility.
3. Home care providers use the mattress to support patients recovering from surgery or those with chronic conditions that limit mobility.
4. The mattress is also used in rehabilitation centers to aid in the recovery of patients with spinal cord injuries or other mobility issues.
5. In palliative care, the mattress helps to improve the quality of life for patients by reducing discomfort and preventing pressure ulcers.

The LM Series Medical Anti-Decubitus Air Mattress is a versatile tool in clinical settings, offering effective pressure ulcer prevention and treatment for a wide range of patients. Its use in hospitals, nursing homes, and home care settings highlights its importance in improving patient outcomes.

Purchasing Guide

When purchasing the LM Series Medical Anti-Decubitus Air Mattress, consider factors such as product specifications, types, budget, and intended use to ensure you select the right model for your needs.

1. Product specifications: Review the dimensions, weight capacity, and performance indicators to ensure the mattress meets your requirements.
2. Product types: Choose between different models based on patient needs, such as those with additional features like built-in alarms or advanced pressure settings.
3. Budget: Consider the cost of the mattress and any additional accessories, such as replacement air cells or extra air pumps.
4. Usage scenarios: Determine where the mattress will be used—whether in a hospital, nursing home, or home care setting—to select the most appropriate model.

Purchasing the LM Series Medical Anti-Decubitus Air Mattress requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can ensure that you select the right mattress to meet your needs and improve patient care.

 Precautions

When using the LM Series Medical Anti-Decubitus Air Mattress, it is important to follow safety guidelines to ensure proper function and patient safety.

1. Always check the air pump and mattress for any signs of damage before use to prevent malfunctions.
2. Ensure that the mattress is properly inflated and that the air cells are functioning correctly to provide adequate pressure relief.
3. Regularly clean the mattress and air pump to maintain hygiene and prevent infections.
4. Monitor patients for any signs of discomfort or skin irritation and adjust the mattress settings as needed.
5. Follow the manufacturer's instructions for maintenance and replacement of parts to ensure the mattress remains in good working condition.

Using the LM Series Medical Anti-Decubitus Air Mattress safely requires attention to detail and regular maintenance. By following these precautions, you can ensure that the mattress functions properly and provides the best possible care for patients.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files