LH-8000 Series Transcranial Doppler Blood Flow Analyzer
The LH-8000 Series Transcranial Doppler Blood Flow Analyzer is composed of a main unit, ultrasound probes, a display, a TCD-specific USB module, a cart, and TCD software. The ultrasound probes include a 2MHz pulsed Doppler (PW) probe and a 4MHz continuous Doppler (CW) probe. The patient-contact portion of the probes is made of 5010 epoxy resin. Key parameters include: PW ultrasound frequency of 2MHz, CW ultrasound frequency of 4MHz, velocity measurement ranges of 20cm/s to 200cm/s for PW and 10cm/s to 100cm/s for CW, maximum working distances of 160mm for PW and 30mm for CW, and a continuous working time of over 4 hours.
Product English Name:
LH-8000 Series Transcranial Doppler Blood Flow Analyzer
Alias:
TCD Analyzer,Ultrasound Doppler System
Intended Use:
The LH-8000 Series is designed for the detection of intracranial and extracranial blood flow. It is widely used in clinical settings to assess cerebral blood flow velocity, detect vascular abnormalities, and monitor patients with conditions such as stroke, vasospasm, and other cerebrovascular diseases.
Product Introduction

The LH-8000 Series Transcranial Doppler Blood Flow Analyzer is a state-of-the-art medical device designed for non-invasive monitoring and analysis of cerebral blood flow. It combines advanced ultrasound technology with user-friendly software to provide accurate and reliable measurements of blood flow velocity in the brain. This device is essential for diagnosing and managing various cerebrovascular conditions, offering clinicians a powerful tool for patient care.

1. The LH-8000 Series features advanced ultrasound technology, including both pulsed and continuous Doppler modes, allowing for precise measurement of blood flow velocities in different vascular regions.
2. The device is composed of a main unit, high-quality ultrasound probes, a display, and specialized software. The probes are designed with patient comfort in mind, using 5010 epoxy resin for the contact portion.
3. The LH-8000 Series is primarily used for detecting intracranial and extracranial blood flow, making it invaluable in diagnosing conditions such as stroke, vasospasm, and other cerebrovascular diseases.

The LH-8000 Series Transcranial Doppler Blood Flow Analyzer, also known as the TCD Analyzer, is a versatile and reliable tool for assessing cerebral blood flow. Its advanced features and user-friendly design make it a preferred choice for clinicians dealing with cerebrovascular conditions.

Main Features

The LH-8000 Series offers a range of features designed to enhance the accuracy and efficiency of cerebral blood flow analysis. These include dual Doppler modes, high-resolution imaging, and user-friendly software.

1. The device supports both pulsed and continuous Doppler modes, allowing for versatile blood flow measurement across different vascular regions.
2. High-resolution imaging provides clear and detailed views of blood flow patterns, aiding in accurate diagnosis.
3. The user-friendly software interface simplifies operation and data analysis, making it accessible to clinicians of all experience levels.
4. The device is equipped with a TCD-specific USB module, enabling easy data transfer and storage.
5. The LH-8000 Series is designed for continuous operation, with a working time of over 4 hours, ensuring reliability during extended procedures.

The LH-8000 Series stands out for its dual Doppler modes, high-resolution imaging, and user-friendly software. These features make it an indispensable tool for clinicians, offering both precision and ease of use in cerebral blood flow analysis.

Clinical Applications

The LH-8000 Series is widely used in clinical settings for the diagnosis and monitoring of cerebrovascular conditions. Its non-invasive nature and accurate measurements make it a valuable tool for patient care.

1. The device is commonly used in stroke diagnosis, providing real-time data on cerebral blood flow velocity.
2. It is also employed in the detection of vasospasm, particularly in patients recovering from subarachnoid hemorrhage.
3. The LH-8000 Series is used to monitor patients with cerebrovascular diseases, offering continuous assessment of blood flow changes.
4. It is utilized in research settings to study cerebral hemodynamics and the effects of various treatments on blood flow.
5. The device is also used in preoperative assessments to evaluate the risk of cerebrovascular complications during surgery.

The LH-8000 Series has a broad range of clinical applications, from stroke diagnosis to preoperative assessments. Its non-invasive nature and accurate measurements make it a trusted tool in both clinical and research settings.

Purchasing Guide

When purchasing the LH-8000 Series, it is important to consider factors such as product specifications, types, budget, and intended use scenarios to ensure the device meets your clinical needs.

1. Product specifications, including ultrasound frequency, velocity measurement range, and working distance, should be carefully evaluated to match your clinical requirements.
2. Consider the types of probes and software included, as these can significantly impact the device's functionality and ease of use.
3. Budget considerations should include not only the initial purchase cost but also ongoing maintenance and potential upgrades.
4. Assess the intended use scenarios, such as whether the device will be used in a clinical or research setting, to ensure it meets your specific needs.

Purchasing the LH-8000 Series requires careful consideration of product specifications, types, budget, and use scenarios. By evaluating these factors, you can ensure the device meets your clinical needs and provides long-term value.

 Precautions

Proper use and maintenance of the LH-8000 Series are essential to ensure accurate measurements and prolong the device's lifespan. Key precautions include regular calibration, proper probe handling, and adherence to safety guidelines.

1. Regular calibration of the device is necessary to maintain measurement accuracy and reliability.
2. Proper handling of the ultrasound probes is crucial to prevent damage and ensure patient safety.
3. Adherence to safety guidelines, including proper sterilization of probes, is essential to prevent cross-contamination.
4. Ensure the device is used within its specified operating conditions, including temperature and humidity ranges, to avoid malfunctions.
5. Regular maintenance and inspection of the device and its components are recommended to identify and address potential issues early.

The LH-8000 Series requires careful handling and maintenance to ensure optimal performance. By following proper precautions, such as regular calibration and adherence to safety guidelines, you can maximize the device's accuracy and longevity.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files