L-γ-Glutamyltransferase Assay Kit (Continuous Monitoring Method)
The kit consists of two reagents: R1 contains Tris, glycylglycine, and sodium azide, while R2 contains Glucana. The reagent blank absorbance is ≤1.0, with a blank absorbance change rate of ≤0.002 per minute. It offers high accuracy with a relative deviation of ≤±10%, intra-assay precision CV ≤8%, inter-assay precision ≤12%, and a linear range of up to 500 U/L.
Product English Name:
L-γ-Glutamyltransferase Assay Kit (Continuous Monitoring Method)
Alias:
GGT Assay Kit,Gamma-GT Test Kit
Intended Use:
This product is designed for in vitro determination of L-γ-glutamyltransferase activity in human serum. It is widely used in clinical diagnostics to assess liver function and detect liver-related diseases.
Product Introduction

The L-γ-Glutamyltransferase Assay Kit is a high-quality diagnostic tool used to measure the activity of L-γ-glutamyltransferase (GGT) in human serum. This enzyme is a key biomarker for liver and biliary tract diseases. The kit employs a continuous monitoring method, ensuring accurate and reliable results. It is suitable for clinical laboratories and research institutions, providing essential data for diagnosing and monitoring liver health.

1. The kit features a continuous monitoring method, which ensures real-time measurement of GGT activity with high precision and sensitivity. This method is particularly useful for detecting subtle changes in enzyme levels, making it ideal for early diagnosis and monitoring of liver diseases.
2. The composition of the kit includes two reagents: R1 and R2. R1 contains Tris, glycylglycine, and sodium azide, while R2 contains Glucana. These components work together to provide a stable and accurate measurement environment, ensuring consistent results across different batches.
3. The primary use of this kit is to measure GGT activity in human serum, which is crucial for diagnosing liver and biliary tract diseases. Elevated GGT levels are often associated with conditions such as hepatitis, cirrhosis, and bile duct obstruction, making this kit an essential tool in clinical diagnostics.

The L-γ-Glutamyltransferase Assay Kit, also known as the GGT Assay Kit, is a reliable and accurate diagnostic tool for measuring GGT activity in human serum. Its continuous monitoring method and stable reagent composition make it a preferred choice for clinical laboratories. This kit plays a vital role in diagnosing and monitoring liver-related diseases, providing essential data for patient care.

Main Features

The L-γ-Glutamyltransferase Assay Kit offers high accuracy, precision, and a wide linear range, making it an essential tool for clinical diagnostics. Its continuous monitoring method ensures real-time measurement of GGT activity, providing reliable results for liver function assessment.

1. The kit employs a continuous monitoring method, which allows for real-time measurement of GGT activity. This method is highly sensitive and provides accurate results, even at low enzyme concentrations.
2. The reagents in the kit are carefully formulated to ensure stability and consistency. R1 contains Tris, glycylglycine, and sodium azide, while R2 contains Glucana. These components work together to provide a stable measurement environment.
3. The kit offers high accuracy with a relative deviation of ≤±10%, ensuring that the results are reliable and consistent. This level of accuracy is crucial for clinical diagnostics, where precise measurements are essential.
4. The intra-assay precision CV is ≤8%, and the inter-assay precision is ≤12%, indicating that the kit provides consistent results across different batches and over time. This consistency is vital for long-term monitoring of patients.
5. The linear range of the kit is up to 500 U/L, making it suitable for measuring a wide range of GGT activity levels. This broad range ensures that the kit can be used in various clinical scenarios, from routine check-ups to complex diagnostic cases.

The L-γ-Glutamyltransferase Assay Kit is a versatile and reliable diagnostic tool, offering high accuracy, precision, and a wide linear range. Its continuous monitoring method and stable reagent composition make it an essential tool for clinical laboratories, providing reliable results for liver function assessment and disease diagnosis.

Clinical Applications

The L-γ-Glutamyltransferase Assay Kit is widely used in clinical settings to diagnose and monitor liver and biliary tract diseases. It provides essential data for assessing liver function and detecting conditions such as hepatitis, cirrhosis, and bile duct obstruction.

1. The kit is commonly used in clinical laboratories to measure GGT activity in human serum. Elevated GGT levels are often associated with liver diseases, making this kit an essential tool for diagnosing conditions such as hepatitis and cirrhosis.
2. In addition to liver diseases, the kit is also used to detect bile duct obstruction. Elevated GGT levels can indicate a blockage in the bile ducts, which can lead to serious complications if not treated promptly.
3. The kit is also used in research settings to study the effects of various drugs and toxins on liver function. By measuring GGT activity, researchers can assess the impact of these substances on liver health.
4. The continuous monitoring method used in the kit allows for real-time measurement of GGT activity, making it ideal for monitoring patients with chronic liver diseases. This method provides accurate and reliable results, even in complex cases.
5. The kit is also used in routine health check-ups to assess liver function. By measuring GGT activity, healthcare providers can detect early signs of liver disease and take preventive measures to protect patient health.

The L-γ-Glutamyltransferase Assay Kit is a valuable tool in clinical diagnostics, providing essential data for diagnosing and monitoring liver and biliary tract diseases. Its continuous monitoring method and high accuracy make it an indispensable tool for healthcare providers, ensuring reliable results for patient care.

Purchasing Guide

When purchasing the L-γ-Glutamyltransferase Assay Kit, it is important to consider factors such as product specifications, types, budget, and intended use. This guide provides essential information to help you make an informed decision.

1. Product specifications: The kit includes two reagents, R1 and R2, with specific compositions and performance characteristics. Ensure that the kit meets your laboratory's requirements for accuracy, precision, and linear range.
2. Product types: The kit is available in different sizes and configurations to suit various laboratory needs. Choose the type that best fits your workflow and testing volume.
3. Budget: Consider the cost of the kit, including any additional expenses such as shipping and handling. Compare prices from different suppliers to find the best deal without compromising on quality.
4. Intended use: Determine the primary use of the kit, whether for routine diagnostics, research, or specialized testing. Ensure that the kit's features and performance characteristics align with your intended use.

Purchasing the L-γ-Glutamyltransferase Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By following this guide, you can make an informed decision that meets your laboratory's needs and ensures reliable results for patient care.

 Precautions

When using the L-γ-Glutamyltransferase Assay Kit, it is important to follow proper handling and storage procedures to ensure accurate results and maintain the integrity of the reagents.

1. Always store the kit at the recommended temperature to maintain the stability of the reagents. Improper storage can lead to degradation of the components, affecting the accuracy of the results.
2. Handle the reagents with care, avoiding contamination. Use clean and sterile equipment to prevent any interference with the assay.
3. Follow the manufacturer's instructions for preparing and using the reagents. Deviating from the recommended procedures can lead to inaccurate results.
4. Dispose of used reagents and materials according to local regulations. Proper disposal is essential to prevent environmental contamination and ensure safety.
5. Regularly calibrate and maintain the equipment used with the kit to ensure consistent and accurate results. Proper maintenance is crucial for long-term reliability.

Using the L-γ-Glutamyltransferase Assay Kit requires careful attention to handling, storage, and disposal procedures. By following these precautions, you can ensure accurate results and maintain the integrity of the reagents, providing reliable data for patient care.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files