The KJ20 Series Applanation Tonometer is a precision instrument used in ophthalmology to measure intraocular pressure. It is known for its accuracy, ease of use, and robust design, making it a preferred choice for eye care professionals. The device is available in two models, Type A and Type B, catering to different observational preferences.
1. The KJ20 Series Applanation Tonometer features a high-precision applanation prism that ensures accurate pressure readings. Its ergonomic design allows for comfortable handling during prolonged use.
2. The device is constructed with a durable casing, a balanced rod for stability, and a weight holder that ensures consistent pressure application. The dial provides clear and easy-to-read measurements.
3. Primarily used in clinical settings, the KJ20 Series is essential for diagnosing and managing eye conditions such as glaucoma. Its reliable performance makes it a staple in ophthalmology practices worldwide.
The KJ20 Series Applanation Tonometer, also known as the Ocular Tonometer, is a vital tool in eye care. Its precise measurement capabilities and user-friendly design make it indispensable for diagnosing and monitoring intraocular pressure. Whether you're a seasoned ophthalmologist or a medical student, this device offers reliability and ease of use.
The KJ20 Series Applanation Tonometer is renowned for its precision, durability, and ease of use. It offers accurate intraocular pressure measurements, making it a trusted tool in ophthalmology.
1. The applanation prism is designed for high accuracy, ensuring reliable pressure readings every time.
2. The balance rod and weight holder provide stability, allowing for consistent pressure application during measurements.
3. The dial is easy to read, with clear markings that facilitate quick and accurate readings.
4. The device is available in two models, Type A and Type B, catering to different observational preferences.
5. The durable casing ensures the device remains protected during transport and use, extending its lifespan.
The KJ20 Series Applanation Tonometer stands out for its precision and reliability. Its thoughtful design and robust construction make it a favorite among eye care professionals, ensuring accurate intraocular pressure measurements every time.
The KJ20 Series Applanation Tonometer is widely used in clinical settings to measure intraocular pressure, aiding in the diagnosis and management of eye conditions such as glaucoma.
1. In ophthalmology clinics, the KJ20 Series is used to screen patients for glaucoma, a condition characterized by increased intraocular pressure.
2. The device is also employed in routine eye exams to monitor the eye health of patients, particularly those at risk for glaucoma.
3. In hospital settings, the KJ20 Series is used post-surgery to ensure that intraocular pressure remains within safe levels.
4. The tonometer is also utilized in research studies to gather data on intraocular pressure variations in different populations.
5. Its ease of use and accuracy make it a valuable tool in telemedicine, allowing remote diagnosis and monitoring of eye conditions.
The KJ20 Series Applanation Tonometer is a versatile tool in clinical practice, essential for diagnosing and managing eye conditions. Its accuracy and ease of use make it a reliable choice for eye care professionals, ensuring patient safety and effective treatment.
When purchasing the KJ20 Series Applanation Tonometer, consider factors such as product specifications, types, budget, and intended use to ensure you select the right model for your needs.
1. Product specifications: Ensure the tonometer meets your required measurement range and accuracy. The KJ20 Series offers a range of 0 to 10.64 KPa with a precision prism diameter of 7mm.
2. Product types: Choose between Type A and Type B based on your observational preferences. Type A is for left-eye observation, while Type B offers flexibility with both left and right-eye options.
3. Budget: Consider the cost of the device, including any additional accessories or maintenance requirements. The KJ20 Series is a cost-effective solution for accurate intraocular pressure measurement.
4. Usage scenarios: Determine where and how the tonometer will be used. Whether in a clinic, hospital, or research setting, the KJ20 Series is designed to meet diverse needs.
Purchasing the KJ20 Series Applanation Tonometer requires careful consideration of specifications, types, and budget. Its versatility and reliability make it a worthwhile investment for any eye care practice.
Proper handling and maintenance of the KJ20 Series Applanation Tonometer are crucial to ensure accurate measurements and prolong the device's lifespan.
1. Always clean the applanation prism before and after use to prevent contamination and ensure accurate readings.
2. Handle the device with care to avoid damage to the delicate components, particularly the balance rod and prism.
3. Regularly calibrate the tonometer to maintain its accuracy. Use a calibration kit as recommended by the manufacturer.
4. Store the device in a safe, dry place to protect it from environmental factors that could affect its performance.
5. Follow the manufacturer's guidelines for maintenance and servicing to ensure the device remains in optimal condition.
Taking proper care of the KJ20 Series Applanation Tonometer is essential for its longevity and accuracy. Regular cleaning, careful handling, and routine maintenance will ensure it continues to provide reliable intraocular pressure measurements.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.