Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
Kappa Detection Reagent (Flow Cytometry-FITC)
The Kappa Detection Reagent consists of a fluorescent FITC-labeled Kappa monoclonal antibody. Each bottle contains a concentration of 25µg per 1.0mL of phosphate-buffered saline (PBS). This reagent is specifically designed for use in flow cytometry to detect Kappa antigen expression in human bone marrow cells. Detailed instructions and specifications can be found in the product manual.
Product English Name:
Kappa Detection Reagent (Flow Cytometry-FITC)
Alias:
Kappa FITC Reagent,Kappa Flow Cytometry Kit
Intended Use:
This product is intended for in vitro use to identify and quantify the expression levels of Kappa antigen in human bone marrow cells. It is a critical tool in immunophenotyping and helps in diagnosing and monitoring various hematological disorders, including multiple myeloma and other plasma cell dyscrasias.
Product Introduction

The Kappa Detection Reagent (Flow Cytometry-FITC) is a specialized diagnostic tool designed for the precise detection of Kappa antigen expression in human bone marrow cells. Utilizing a fluorescent FITC-labeled monoclonal antibody, this reagent offers high sensitivity and specificity, making it an essential component in flow cytometry-based immunophenotyping. It is widely used in clinical laboratories for the diagnosis and monitoring of hematological malignancies.

1. The Kappa Detection Reagent is characterized by its high sensitivity and specificity, thanks to the FITC-labeled monoclonal antibody. This ensures accurate detection of Kappa antigen expression, even at low levels, which is crucial for early diagnosis and monitoring of diseases.
2. The reagent is composed of a fluorescent FITC-labeled Kappa monoclonal antibody, suspended in a phosphate-buffered saline (PBS) solution. The concentration is precisely calibrated at 25µg per 1.0mL, ensuring consistent performance across different batches.
3. The primary use of this reagent is in the identification and quantification of Kappa antigen expression in human bone marrow cells. It is particularly valuable in the diagnosis and monitoring of hematological disorders such as multiple myeloma, where Kappa antigen expression is a key diagnostic marker.

The Kappa Detection Reagent, also known as the Kappa FITC Reagent, is a vital tool in the field of hematology. Its high sensitivity and specificity make it indispensable for the accurate detection of Kappa antigen expression in bone marrow cells. Whether you're diagnosing multiple myeloma or monitoring disease progression, this reagent offers reliable and consistent results.

Main Features

The Kappa Detection Reagent offers high sensitivity and specificity in detecting Kappa antigen expression, making it a crucial tool for immunophenotyping in clinical diagnostics.

1. High Sensitivity: The FITC-labeled monoclonal antibody ensures that even low levels of Kappa antigen can be detected, which is essential for early diagnosis.
2. Specificity: The reagent is highly specific to Kappa antigen, reducing the risk of cross-reactivity with other antigens.
3. Consistency: Each batch is calibrated to a concentration of 25µg per 1.0mL, ensuring reliable performance across different uses.
4. Ease of Use: The reagent is ready to use, requiring minimal preparation, which saves time in the laboratory.
5. Versatility: Suitable for use in various flow cytometry applications, including research and clinical diagnostics.

The Kappa Detection Reagent stands out for its high sensitivity, specificity, and consistency. Whether you're conducting research or diagnosing patients, this reagent offers reliable and accurate results, making it a must-have in any clinical laboratory.

Clinical Applications

The Kappa Detection Reagent is widely used in clinical settings for the diagnosis and monitoring of hematological disorders, particularly those involving plasma cells.

1. Diagnosis of Multiple Myeloma: The reagent is used to detect Kappa antigen expression, a key marker in the diagnosis of multiple myeloma.
2. Monitoring Disease Progression: It helps in tracking the progression of hematological malignancies by quantifying Kappa antigen levels over time.
3. Research Applications: The reagent is also used in research to study the role of Kappa antigen in various hematological disorders.
4. Immunophenotyping: It is a critical component in immunophenotyping panels used to characterize different cell populations in bone marrow samples.
5. Clinical Trials: The reagent is used in clinical trials to evaluate the efficacy of new treatments targeting Kappa antigen-expressing cells.

In clinical practice, the Kappa Detection Reagent is indispensable for diagnosing and monitoring hematological disorders. Its ability to accurately detect Kappa antigen expression makes it a valuable tool in both routine diagnostics and advanced research.

Purchasing Guide

When purchasing the Kappa Detection Reagent, it is important to consider product specifications, types, budget, and intended use to ensure it meets your laboratory's needs.

1. Product Specifications: Ensure the reagent's concentration (25µg per 1.0mL) and FITC labeling meet your experimental requirements.
2. Product Types: Choose between different packaging sizes and formats based on your laboratory's throughput and storage capacity.
3. Budget: Consider the cost per test and overall budget to ensure the reagent is cost-effective for your laboratory.
4. Usage Scenarios: Evaluate the reagent's compatibility with your flow cytometry equipment and protocols to ensure seamless integration into your workflow.

Purchasing the Kappa Detection Reagent requires careful consideration of various factors, including product specifications, types, and budget. By aligning these factors with your laboratory's needs, you can ensure that the reagent will deliver optimal performance and value.

 Precautions

Proper handling and storage of the Kappa Detection Reagent are essential to maintain its efficacy and ensure accurate results.

1. Storage Conditions: Store the reagent at 2-8°C and protect it from light to prevent degradation of the FITC label.
2. Handling: Use aseptic techniques to avoid contamination, which could affect the reagent's performance.
3. Expiration Date: Always check the expiration date before use to ensure the reagent is still effective.
4. Disposal: Dispose of used reagents according to local regulations for biohazardous materials.
5. Quality Control: Regularly perform quality control checks to ensure the reagent is performing as expected.

To get the most out of the Kappa Detection Reagent, it's crucial to follow proper storage, handling, and disposal protocols. By adhering to these precautions, you can ensure the reagent remains effective and delivers reliable results every time.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files