Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
HM-type Esophageal Cardia Stricture Dilator
The HM-type Esophageal Cardia Stricture Dilator is composed of six dilation rods with varying diameters (5mm, 7mm, 9mm, 11mm, 13mm, 15mm), a guidewire, and a mouthpiece. The product is non-sterile, designed for medical procedures requiring precise dilation of the esophageal cardia region.
Product English Name:
HM-type Esophageal Cardia Stricture Dilator
Alias:
Esophageal Dilator,Cardia Stricture Expander
Intended Use:
This device is specifically designed for the dilation treatment of esophageal cardia strictures caused by various etiologies. It is used in clinical settings to alleviate narrowing in the esophageal cardia, facilitating better passage of food and liquids.
Product Introduction

The HM-type Esophageal Cardia Stricture Dilator is a specialized medical device used to treat narrowing in the esophageal cardia. It is composed of multiple dilation rods, a guidewire, and a mouthpiece, making it versatile for different clinical needs. This product is non-sterile and requires proper handling and preparation before use.

1. The HM-type Esophageal Cardia Stricture Dilator features six dilation rods with diameters ranging from 5mm to 15mm, allowing for gradual and controlled dilation of the esophageal cardia. This design ensures precise treatment tailored to the patient's specific condition.
2. The device includes a guidewire for accurate placement and a mouthpiece to ensure patient comfort during the procedure. The non-sterile nature of the product requires proper sterilization before use, adhering to medical protocols.
3. This dilator is primarily used to treat esophageal cardia strictures caused by various factors, including scarring, tumors, or congenital conditions. Its versatility and precision make it a valuable tool in gastroenterology and related medical fields.

The HM-type Esophageal Cardia Stricture Dilator, also known as the Esophageal Dilator or Cardia Stricture Expander, is a highly effective tool for treating narrowing in the esophageal cardia. Its design, featuring multiple dilation rods and a guidewire, ensures precise and controlled treatment, making it indispensable in clinical settings.

Main Features

The HM-type Esophageal Cardia Stricture Dilator offers precise dilation of the esophageal cardia, with six rods of varying diameters, a guidewire for accurate placement, and a mouthpiece for patient comfort.

1. The device includes six dilation rods with diameters ranging from 5mm to 15mm, allowing for gradual and controlled dilation tailored to the patient's needs.
2. A guidewire ensures accurate placement of the dilation rods, reducing the risk of complications during the procedure.
3. The mouthpiece enhances patient comfort and stability during the dilation process, making the procedure more tolerable.
4. The non-sterile nature of the product requires proper sterilization before use, ensuring safety and compliance with medical standards.
5. The dilator is designed for versatility, making it suitable for treating various causes of esophageal cardia strictures, including scarring, tumors, and congenital conditions.

The HM-type Esophageal Cardia Stricture Dilator stands out for its precision and versatility. With six dilation rods, a guidewire, and a mouthpiece, it ensures effective and comfortable treatment for patients with esophageal cardia strictures.

Clinical Applications

The HM-type Esophageal Cardia Stricture Dilator is widely used in clinical settings to treat narrowing in the esophageal cardia caused by various conditions, including scarring, tumors, and congenital abnormalities.

1. The device is commonly used in gastroenterology to treat esophageal strictures caused by chronic acid reflux, ensuring improved passage of food and liquids.
2. It is also effective in treating strictures resulting from surgical procedures or radiation therapy, providing relief and improving quality of life for patients.
3. The dilator is used in pediatric cases to address congenital esophageal strictures, offering a safe and effective treatment option for young patients.
4. In oncology, the device is utilized to manage strictures caused by tumors, facilitating better nutritional intake and overall patient care.
5. The HM-type dilator is also employed in emergency settings to address acute esophageal obstructions, providing immediate relief and preventing further complications.

The HM-type Esophageal Cardia Stricture Dilator is a versatile tool in clinical practice, addressing a wide range of conditions that cause esophageal narrowing. Its precision and adaptability make it invaluable in gastroenterology, oncology, and pediatric care.

Purchasing Guide

When purchasing the HM-type Esophageal Cardia Stricture Dilator, consider product specifications, types, budget, and intended use to ensure it meets your clinical needs.

1. Evaluate the product specifications, including the range of dilation rod diameters and the inclusion of a guidewire and mouthpiece, to ensure compatibility with your procedures.
2. Choose the appropriate product type based on your clinical requirements, whether for general gastroenterology, pediatric care, or oncology.
3. Establish a budget that accounts for the device's cost, sterilization requirements, and potential maintenance needs.
4. Consider the intended use and patient population to ensure the dilator is suitable for your specific clinical scenarios, such as treating chronic strictures or acute obstructions.

Purchasing the HM-type Esophageal Cardia Stricture Dilator requires careful consideration of its specifications, intended use, and budget. By evaluating these factors, you can ensure the device meets your clinical needs and provides effective treatment for your patients.

 Precautions

Proper handling and sterilization of the HM-type Esophageal Cardia Stricture Dilator are essential to ensure patient safety and effective treatment.

1. Always sterilize the device before use, as it is non-sterile upon purchase, to prevent infections and ensure patient safety.
2. Follow the manufacturer's guidelines for proper placement and use of the dilation rods and guidewire to avoid complications during the procedure.
3. Monitor patients closely during and after the procedure to identify any adverse reactions or complications, such as bleeding or perforation.
4. Ensure the mouthpiece is securely placed to maintain patient comfort and stability throughout the dilation process.
5. Regularly inspect the device for wear and tear, and replace any damaged components to maintain its effectiveness and safety.

The HM-type Esophageal Cardia Stricture Dilator requires careful handling and sterilization to ensure safe and effective use. By adhering to proper protocols and monitoring patients closely, healthcare providers can minimize risks and achieve optimal treatment outcomes.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files