Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
HDX-B Ethylene Oxide Sterilizer
The HDX-B Ethylene Oxide Sterilizer is composed of three main systems: the sterilization chamber, the residual removal system, and the computer control system. The sterilization chamber features a cabinet structure with heating, humidification, crushing, special sealing, and door locking mechanisms. The residual removal system includes vacuum, pneumatic, filtration, and cleaning devices. The computer control system is equipped with an imported LCD screen, a Chinese operating interface, large-capacity storage chips, data analysis and processing systems, printing, and alarm systems. The sterilizer is designed with a maximum negative pressure of -0.08MPa, temperature control accuracy within ±3℃, an average leakage rate of ≤0.1KPa/min, and the ability to reach a relative humidity of over 75%.
Product English Name:
HDX-B Ethylene Oxide Sterilizer
Alias:
EO Sterilizer,Gas Sterilizer
Intended Use:
This product is specifically designed for the sterilization of clinical medical instruments, ensuring they are free from microbial contamination and safe for use in medical procedures.
Product Introduction

The HDX-B Ethylene Oxide Sterilizer is a state-of-the-art device designed for the effective sterilization of medical instruments. It combines advanced technology with user-friendly features to ensure optimal performance and safety. The sterilizer is widely used in hospitals, clinics, and laboratories to maintain the highest standards of hygiene and infection control.

1. The HDX-B Ethylene Oxide Sterilizer is known for its robust construction and advanced features. It includes a sterilization chamber with multiple mechanisms to ensure thorough sterilization, such as heating, humidification, and crushing. The chamber is designed to maintain precise temperature and humidity levels, ensuring effective sterilization.
2. The sterilizer's residual removal system is equipped with vacuum, pneumatic, filtration, and cleaning devices. These components work together to remove any residual ethylene oxide gas, ensuring the safety of the sterilized instruments. The system is designed to operate efficiently, with a maximum negative pressure of -0.08MPa and an average leakage rate of ≤0.1KPa/min.
3. The computer control system is the brain of the sterilizer, featuring an imported LCD screen, a Chinese operating interface, and large-capacity storage chips. This system allows for easy operation, data analysis, and processing. It also includes printing and alarm systems to ensure the sterilization process is monitored and controlled effectively.

The HDX-B Ethylene Oxide Sterilizer, also known as the EO Sterilizer or Gas Sterilizer, is a highly efficient and reliable device for sterilizing medical instruments. Its advanced features, including the sterilization chamber, residual removal system, and computer control system, make it an essential tool in maintaining hygiene and safety in medical settings.

Main Features

The HDX-B Ethylene Oxide Sterilizer offers a range of advanced features designed to ensure effective and safe sterilization of medical instruments. These features include precise temperature and humidity control, efficient residual gas removal, and user-friendly operation.

1. The sterilization chamber is equipped with heating, humidification, and crushing mechanisms to ensure thorough sterilization. The chamber maintains precise temperature and humidity levels, ensuring the effectiveness of the sterilization process.
2. The residual removal system includes vacuum, pneumatic, filtration, and cleaning devices. These components work together to remove any residual ethylene oxide gas, ensuring the safety of the sterilized instruments.
3. The computer control system features an imported LCD screen, a Chinese operating interface, and large-capacity storage chips. This system allows for easy operation, data analysis, and processing, ensuring the sterilization process is monitored and controlled effectively.
4. The sterilizer is designed with a maximum negative pressure of -0.08MPa and an average leakage rate of ≤0.1KPa/min. These features ensure the sterilizer operates efficiently and safely.
5. The sterilizer includes printing and alarm systems to monitor and control the sterilization process. These systems provide real-time feedback and alerts, ensuring the sterilization process is completed successfully.

The HDX-B Ethylene Oxide Sterilizer is a highly efficient and reliable device for sterilizing medical instruments. Its advanced features, including precise temperature and humidity control, efficient residual gas removal, and user-friendly operation, make it an essential tool in maintaining hygiene and safety in medical settings.

Clinical Applications

The HDX-B Ethylene Oxide Sterilizer is widely used in clinical settings for the sterilization of medical instruments. Its advanced features ensure effective sterilization, making it an essential tool in hospitals, clinics, and laboratories.

1. The sterilizer is used in hospitals to sterilize surgical instruments, ensuring they are free from microbial contamination and safe for use in medical procedures.
2. In clinics, the sterilizer is used to sterilize diagnostic instruments, ensuring accurate and safe diagnostic procedures.
3. Laboratories use the sterilizer to sterilize research instruments, ensuring the integrity of research results and the safety of laboratory personnel.
4. The sterilizer is also used in dental clinics to sterilize dental instruments, ensuring the safety of dental procedures.
5. The sterilizer is used in veterinary clinics to sterilize veterinary instruments, ensuring the safety of animal healthcare procedures.

The HDX-B Ethylene Oxide Sterilizer is an essential tool in clinical settings, ensuring the effective sterilization of medical instruments. Its advanced features and reliable performance make it a trusted choice for hospitals, clinics, and laboratories.

Purchasing Guide

When purchasing the HDX-B Ethylene Oxide Sterilizer, it is important to consider product specifications, types, budget, and usage scenarios to ensure the right product is selected for your needs.

1. Product specifications: Consider the sterilizer's maximum negative pressure, temperature control accuracy, and leakage rate to ensure it meets your sterilization requirements.
2. Product types: Choose between different models of the sterilizer based on your specific needs, such as the size of the sterilization chamber and the type of residual removal system.
3. Budget: Determine your budget and compare the features and prices of different models to find the best value for your investment.
4. Usage scenarios: Consider the specific usage scenarios, such as the type of medical instruments to be sterilized and the frequency of use, to ensure the sterilizer meets your needs.

Purchasing the HDX-B Ethylene Oxide Sterilizer requires careful consideration of product specifications, types, budget, and usage scenarios. By evaluating these factors, you can ensure the right product is selected for your sterilization needs.

 Precautions

When using the HDX-B Ethylene Oxide Sterilizer, it is important to follow safety precautions to ensure the effective and safe sterilization of medical instruments.

1. Always ensure the sterilization chamber is properly sealed before starting the sterilization process to prevent gas leakage.
2. Regularly check and maintain the residual removal system to ensure it is functioning properly and effectively removing residual ethylene oxide gas.
3. Follow the manufacturer's instructions for operating the computer control system to ensure the sterilization process is monitored and controlled effectively.
4. Use the sterilizer in a well-ventilated area to prevent the accumulation of ethylene oxide gas, which can be hazardous to health.
5. Regularly inspect and replace the sterilizer's filters and seals to ensure optimal performance and safety.

Using the HDX-B Ethylene Oxide Sterilizer requires adherence to safety precautions to ensure effective and safe sterilization. By following these precautions, you can maintain the integrity of the sterilization process and ensure the safety of medical instruments and personnel.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files