17-Hydroxycorticosteroid Assay Kit (Latex Enhanced Immunoturbidimetric Method)
The 17-Hydroxycorticosteroid Assay Kit is composed of two main reagents: R1 and R2. R1 reagent contains Tris(hydroxymethyl)aminomethane (Trizma Base), polyethylene glycol 20000 (PEG20000), 17-hydroxycorticosteroid conjugate, and a preservative (Proclin 300). R2 reagent includes latex particles coated with rabbit anti-human 17-hydroxycorticosteroid polyclonal antibodies, disodium hydrogen phosphate (Na2HPO4), potassium dihydrogen phosphate (KH2PO4), and a preservative (Proclin 300).
Product English Name:
17-Hydroxycorticosteroid Assay Kit (Latex Enhanced Immunoturbidimetric Method)
Alias:
17-OHCS Kit,Corticosteroid Test Kit
Intended Use:
This kit is designed for the quantitative in vitro determination of 17-hydroxycorticosteroid levels in human urine. It is widely used in clinical laboratories to assess adrenal cortex function and diagnose related disorders.
Product Introduction

The 17-Hydroxycorticosteroid Assay Kit is a sophisticated diagnostic tool used to measure the concentration of 17-hydroxycorticosteroids in human urine. This kit employs the latex-enhanced immunoturbidimetric method, which ensures high sensitivity and specificity. It is an essential tool for clinicians to evaluate adrenal gland function and diagnose conditions such as Cushing's syndrome and Addison's disease.

1. The kit features a latex-enhanced immunoturbidimetric method, which provides high sensitivity and specificity in detecting 17-hydroxycorticosteroids. This method is known for its accuracy and reliability in clinical diagnostics.
2. The kit consists of two main reagents: R1 and R2. R1 contains Tris(hydroxymethyl)aminomethane, polyethylene glycol, 17-hydroxycorticosteroid conjugate, and a preservative. R2 includes latex particles coated with specific antibodies, phosphate buffers, and a preservative.
3. The primary use of this kit is to quantitatively measure 17-hydroxycorticosteroid levels in human urine. It is crucial for diagnosing adrenal gland disorders and monitoring treatment efficacy.

The 17-Hydroxycorticosteroid Assay Kit, also known as the 17-OHCS Kit, is a vital diagnostic tool in clinical laboratories. Its high sensitivity and specificity make it indispensable for assessing adrenal gland function and diagnosing related disorders. The kit's composition and method ensure accurate and reliable results, making it a trusted choice for healthcare professionals.

Main Features

The 17-Hydroxycorticosteroid Assay Kit offers high sensitivity and specificity in detecting 17-hydroxycorticosteroids. It is designed for easy use in clinical laboratories, providing reliable results for adrenal function assessment.

1. High Sensitivity: The kit's latex-enhanced immunoturbidimetric method ensures precise detection of low concentrations of 17-hydroxycorticosteroids.
2. Specificity: The use of specific antibodies in the R2 reagent guarantees accurate identification of 17-hydroxycorticosteroids without cross-reactivity.
3. Ease of Use: The kit is designed for straightforward application in clinical settings, with clear instructions and minimal preparation required.
4. Reliability: The inclusion of preservatives and stable reagents ensures consistent performance over time.
5. Comprehensive: The kit provides all necessary components for accurate measurement, including buffers and conjugates.

The 17-Hydroxycorticosteroid Assay Kit stands out for its high sensitivity, specificity, and ease of use. It is a reliable tool for clinical laboratories, offering accurate results for adrenal function assessment. The kit's comprehensive design and stable reagents make it a preferred choice for healthcare professionals.

Clinical Applications

The 17-Hydroxycorticosteroid Assay Kit is widely used in clinical settings to diagnose and monitor adrenal gland disorders. It is essential for evaluating conditions such as Cushing's syndrome and Addison's disease.

1. Diagnosis of Cushing's Syndrome: The kit helps in identifying elevated levels of 17-hydroxycorticosteroids, a hallmark of Cushing's syndrome.
2. Monitoring Addison's Disease: It is used to assess low levels of 17-hydroxycorticosteroids, indicative of Addison's disease.
3. Adrenal Function Testing: The kit is crucial for evaluating overall adrenal gland function and detecting abnormalities.
4. Treatment Efficacy: It aids in monitoring the effectiveness of treatments for adrenal disorders.
5. Research Applications: The kit is also used in research studies to understand adrenal gland physiology and pathology.

The 17-Hydroxycorticosteroid Assay Kit is indispensable in clinical diagnostics, particularly for adrenal gland disorders. Its applications range from diagnosing Cushing's syndrome to monitoring treatment efficacy, making it a versatile tool in both clinical and research settings.

Purchasing Guide

When purchasing the 17-Hydroxycorticosteroid Assay Kit, consider product parameters, types, budget, and usage scenarios to ensure it meets your clinical needs.

1. Product Parameters: Evaluate the kit's sensitivity, specificity, and stability to ensure it meets your diagnostic requirements.
2. Product Types: Choose between different kit formats based on your laboratory's volume and workflow.
3. Budget: Consider the cost-effectiveness of the kit, including long-term storage and usage costs.
4. Usage Scenarios: Ensure the kit is suitable for your specific clinical applications, such as adrenal function testing or research studies.

Purchasing the 17-Hydroxycorticosteroid Assay Kit requires careful consideration of product parameters, types, budget, and usage scenarios. Ensuring the kit aligns with your clinical needs will guarantee accurate and reliable results in your diagnostic processes.

 Precautions

Proper handling and storage of the 17-Hydroxycorticosteroid Assay Kit are crucial to maintain its performance and ensure accurate results.

1. Storage Conditions: Store the kit at the recommended temperature to preserve reagent stability.
2. Handling: Follow aseptic techniques to prevent contamination during reagent preparation and use.
3. Expiry Date: Always check the expiry date before use to ensure reagent efficacy.
4. Calibration: Regularly calibrate equipment used with the kit to maintain accuracy.
5. Disposal: Dispose of used reagents and materials according to local regulations to ensure safety and environmental compliance.

The 17-Hydroxycorticosteroid Assay Kit requires careful handling and storage to maintain its performance. Adhering to storage conditions, handling protocols, and disposal guidelines ensures accurate results and safe laboratory practices.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files