Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Test Kit (Colloidal Gold Method)
The D-Dimer Test Kit consists of several components: 1. Test reagent: Contains a nitrocellulose membrane coated with D-Dimer monoclonal antibodies and goat anti-mouse IgG, paired D-Dimer monoclonal antibody-labeled colloidal gold particles, sample pad, absorbent pad, and backing card. 2. Sample diluent: 0.5mL per tube, primarily composed of phosphate buffer. 3. Desiccant: Silica gel. 4. Droppers: 25 pieces. 5. Color chart: 1 sheet. 6. Instruction manual: 1 copy. Components from different batches are not interchangeable.
Product English Name:
D-Dimer Test Kit (Colloidal Gold Method)
Alias:
D-Dimer Assay Kit,D-Dimer Rapid Test Kit
Intended Use:
This product is used in conjunction with immunochromatographic result interpretation recorders, universal colloidal gold color interpretation instruments, or immunochromatographic analyzers for the quantitative detection of D-Dimer levels in human plasma or whole blood.
Product Introduction

The D-Dimer Test Kit (Colloidal Gold Method) is a diagnostic tool designed for the rapid and accurate detection of D-Dimer levels in human blood. It utilizes colloidal gold technology, which provides a visual indication of D-Dimer concentration, making it suitable for both clinical and laboratory settings. The kit is user-friendly, with clear instructions and a straightforward procedure, ensuring reliable results.

1. Features: The kit employs colloidal gold particles labeled with D-Dimer monoclonal antibodies, ensuring high specificity and sensitivity. The visual color change on the nitrocellulose membrane allows for easy interpretation of results without the need for complex equipment.
2. Composition: The kit includes a test reagent with a nitrocellulose membrane, sample diluent, desiccant, droppers, a color chart, and an instruction manual. Each component is carefully designed to ensure accurate and consistent results.
3. Usage: The kit is used for the quantitative detection of D-Dimer levels in human plasma or whole blood. It is compatible with various immunochromatographic analyzers, making it versatile for different clinical settings.

The D-Dimer Test Kit (Colloidal Gold Method) is a reliable and efficient tool for detecting D-Dimer levels. Its user-friendly design and high accuracy make it a valuable asset in clinical diagnostics. The kit's components are meticulously crafted to ensure consistent performance, and its compatibility with various analyzers adds to its versatility.

Main Features

The D-Dimer Test Kit offers high sensitivity and specificity in detecting D-Dimer levels. Its colloidal gold technology provides a visual result, making it easy to interpret without complex equipment.

1. High Sensitivity: The kit is designed to detect even low levels of D-Dimer, ensuring accurate results in various clinical conditions.
2. Visual Interpretation: The colloidal gold particles provide a clear color change, allowing for easy result interpretation without the need for additional equipment.
3. User-Friendly: The kit comes with a detailed instruction manual and all necessary components, making it easy to use even for non-specialists.
4. Rapid Results: The test provides results within minutes, making it suitable for urgent clinical situations.
5. Versatile Compatibility: The kit is compatible with various immunochromatographic analyzers, enhancing its utility in different clinical settings.

The D-Dimer Test Kit stands out for its high sensitivity, ease of use, and rapid results. Its visual interpretation feature and compatibility with various analyzers make it a versatile and reliable choice for clinical diagnostics.

Clinical Applications

The D-Dimer Test Kit is widely used in clinical settings for the diagnosis and monitoring of conditions related to blood clotting disorders, such as deep vein thrombosis (DVT) and pulmonary embolism (PE).

1. Diagnosis of DVT: The kit is used to detect elevated D-Dimer levels, which are indicative of deep vein thrombosis.
2. Monitoring PE: It helps in the assessment of pulmonary embolism by measuring D-Dimer levels in patients.
3. Post-Surgical Monitoring: The kit is used to monitor patients after surgery to detect any abnormal clotting activity.
4. Emergency Settings: In emergency rooms, the kit provides rapid results, aiding in the quick diagnosis of clotting disorders.
5. Routine Check-ups: It is also used in routine health check-ups to screen for potential clotting issues.

The D-Dimer Test Kit is an essential tool in clinical diagnostics, particularly for conditions related to blood clotting. Its rapid results and high accuracy make it invaluable in emergency settings, post-surgical monitoring, and routine health check-ups.

Purchasing Guide

When purchasing the D-Dimer Test Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical needs.

1. Product Specifications: Ensure the kit meets the required sensitivity and specificity for your clinical applications.
2. Product Types: Choose between different formats or sizes based on your laboratory's volume and needs.
3. Budget: Consider the cost-effectiveness of the kit, including the price per test and any additional equipment required.
4. Usage Scenarios: Evaluate the kit's compatibility with your existing equipment and its suitability for your clinical setting.

Purchasing the D-Dimer Test Kit requires careful consideration of its specifications, types, and compatibility with your clinical environment. Ensuring it meets your needs will enhance its utility and effectiveness in your diagnostic processes.

 Precautions

Proper handling and storage of the D-Dimer Test Kit are crucial to ensure accurate results and maintain the integrity of the components.

1. Storage Conditions: Store the kit at the recommended temperature to prevent degradation of the reagents.
2. Handling: Avoid contamination by using sterile techniques when handling the kit components.
3. Expiry Date: Always check the expiry date before use to ensure the reagents are still effective.
4. Disposal: Follow proper disposal procedures for used components to prevent biohazard risks.
5. Training: Ensure that all personnel using the kit are adequately trained to avoid errors in testing.

The D-Dimer Test Kit requires careful handling and storage to maintain its effectiveness. Proper training, adherence to storage conditions, and correct disposal methods are essential to ensure accurate and safe use of the kit.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list