Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Assay Kit (Latex Immunoturbidimetric Method)
The D-Dimer Assay Kit is composed of several key components: D-Dimer buffer, which includes a Tris-HCl buffer solution; D-Dimer latex reagent, containing mouse anti-human D-Dimer monoclonal antibody-coated latex particles; D-Dimer calibrator, which consists of D-Dimer, stabilizers, and preservatives; and D-Dimer control, also containing D-Dimer, stabilizers, and preservatives. These components work together to ensure accurate and reliable detection of D-Dimer levels in clinical samples.
Product English Name:
D-Dimer Assay Kit (Latex Immunoturbidimetric Method)
Alias:
D-Dimer Test Kit,D-Dimer Detection Kit
Intended Use:
This kit is specifically designed for the quantitative detection of D-Dimer concentration in serum or plasma. It is widely used in clinical settings to aid in the diagnosis and monitoring of conditions related to blood clotting disorders, such as deep vein thrombosis (DVT), pulmonary embolism (PE), and disseminated intravascular coagulation (DIC).
Product Introduction

The D-Dimer Assay Kit (Latex Immunoturbidimetric Method) is a sophisticated diagnostic tool used to measure the concentration of D-Dimer in blood samples. D-Dimer is a fibrin degradation product that is often elevated in patients with thrombotic disorders. This kit employs a latex immunoturbidimetric method, which is known for its high sensitivity and specificity, making it a reliable choice for clinical laboratories.

1. The D-Dimer Assay Kit is characterized by its high sensitivity and specificity, ensuring accurate detection of D-Dimer levels even at low concentrations. The kit is designed to be user-friendly, with a straightforward protocol that minimizes the risk of errors during the testing process.
2. The kit is composed of several key components, including a D-Dimer buffer, D-Dimer latex reagent, D-Dimer calibrator, and D-Dimer control. Each component is carefully formulated to ensure optimal performance and stability, allowing for consistent and reliable results.
3. The primary use of the D-Dimer Assay Kit is to aid in the diagnosis and monitoring of thrombotic disorders. By providing accurate measurements of D-Dimer levels, the kit helps clinicians make informed decisions regarding patient care, particularly in cases of suspected deep vein thrombosis, pulmonary embolism, or disseminated intravascular coagulation.

The D-Dimer Assay Kit, also known as the D-Dimer Test Kit, is a vital tool in the clinical laboratory. Its high sensitivity and specificity make it an indispensable resource for diagnosing and monitoring thrombotic disorders. The kit's well-designed components and user-friendly protocol ensure that it delivers reliable results, helping clinicians provide the best possible care for their patients.

Main Features

The D-Dimer Assay Kit offers a range of features that make it a preferred choice for clinical laboratories. Its high sensitivity and specificity, combined with a user-friendly protocol, ensure accurate and reliable detection of D-Dimer levels.

1. High Sensitivity: The kit is designed to detect even low concentrations of D-Dimer, making it highly effective for early diagnosis of thrombotic disorders.
2. Specificity: The use of mouse anti-human D-Dimer monoclonal antibodies ensures that the kit specifically targets D-Dimer, reducing the risk of false positives.
3. User-Friendly Protocol: The kit comes with a straightforward protocol that minimizes the risk of errors, making it suitable for use in busy clinical laboratories.
4. Stability: The components of the kit are formulated to ensure long-term stability, allowing for consistent performance over time.
5. Comprehensive Calibration: The kit includes a D-Dimer calibrator, which ensures accurate quantification of D-Dimer levels in clinical samples.

The D-Dimer Assay Kit stands out for its high sensitivity, specificity, and user-friendly design. These features make it an essential tool for clinical laboratories, enabling accurate and reliable detection of D-Dimer levels. The kit's stability and comprehensive calibration further enhance its performance, ensuring that it meets the needs of clinicians and patients alike.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings to aid in the diagnosis and monitoring of thrombotic disorders. Its high sensitivity and specificity make it a valuable tool for clinicians.

1. Diagnosis of Deep Vein Thrombosis (DVT): The kit is used to measure D-Dimer levels in patients suspected of having DVT, helping clinicians confirm the diagnosis.
2. Monitoring Pulmonary Embolism (PE): Elevated D-Dimer levels are often associated with PE, and the kit is used to monitor these levels in patients undergoing treatment.
3. Detection of Disseminated Intravascular Coagulation (DIC): The kit is used to detect elevated D-Dimer levels in patients with DIC, aiding in the diagnosis and management of this condition.
4. Post-Surgical Monitoring: The kit is used to monitor D-Dimer levels in patients after surgery, helping to identify any potential thrombotic complications.
5. Research Applications: The kit is also used in research settings to study the role of D-Dimer in various thrombotic and inflammatory conditions.

The D-Dimer Assay Kit is a versatile tool in clinical practice, used for the diagnosis and monitoring of various thrombotic disorders. Its applications range from diagnosing deep vein thrombosis to monitoring pulmonary embolism and detecting disseminated intravascular coagulation. The kit's reliability and accuracy make it a trusted resource for clinicians and researchers alike.

Purchasing Guide

When purchasing the D-Dimer Assay Kit, it is important to consider factors such as product specifications, types, budget, and intended use to ensure that the kit meets your clinical needs.

1. Product Specifications: Ensure that the kit meets the required sensitivity and specificity for your clinical applications. Check the components included in the kit, such as the buffer, latex reagent, calibrator, and control.
2. Product Types: There may be different versions of the kit available, such as those designed for specific analyzers or with different shelf lives. Choose the type that best suits your laboratory's needs.
3. Budget: Consider the cost of the kit, including any additional reagents or consumables that may be required. Ensure that the kit fits within your laboratory's budget without compromising on quality.
4. Intended Use: Consider the specific clinical applications for which the kit will be used. Ensure that the kit is suitable for the types of samples and conditions you will be testing.

Purchasing the D-Dimer Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that the kit meets your clinical needs and provides reliable results. The right choice will enhance your laboratory's diagnostic capabilities and contribute to better patient outcomes.

 Precautions

When using the D-Dimer Assay Kit, it is important to follow all safety and handling precautions to ensure accurate results and prevent contamination or injury.

1. Proper Handling: Always handle the kit components with care, using appropriate personal protective equipment (PPE) such as gloves and lab coats.
2. Storage Conditions: Store the kit components at the recommended temperatures to maintain their stability and performance. Avoid exposure to extreme temperatures or direct sunlight.
3. Sample Preparation: Ensure that all samples are properly prepared and handled according to the kit's instructions to avoid contamination or inaccurate results.
4. Disposal: Dispose of all used materials, including samples and reagents, in accordance with local regulations and laboratory protocols.
5. Training: Ensure that all personnel using the kit are properly trained in its use and understand the importance of following the protocol to achieve accurate results.

Using the D-Dimer Assay Kit requires careful attention to safety and handling precautions. Proper handling, storage, sample preparation, and disposal are essential to ensure accurate results and prevent contamination or injury. By following these precautions, you can maximize the kit's performance and contribute to a safe and efficient laboratory environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files