Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Calibrator
The D-Dimer Calibrator is composed of a precise concentration of D-Dimer (15.0±3.0 mg/L), along with sodium phosphate dibasic dodecahydrate (6.78 g/L), sodium phosphate monobasic dihydrate (0.16 g/L), sodium chloride (8.77 g/L), and Proclin300 (1 ml/L) as a preservative. The biological source is human serum, ensuring compatibility with human serum samples.
Product English Name:
D-Dimer Calibrator
Alias:
D-Dimer Standard,D-Dimer Reference Material
Intended Use:
This calibrator is specifically designed for the quantitative detection of D-Dimer in human serum. It is used in conjunction with the D-Dimer detection kit (latex-enhanced immunoturbidimetric method) produced by Changzhou Aifukang Biotechnology Co., Ltd., ensuring accurate and reliable calibration for diagnostic purposes.
Product Introduction

The D-Dimer Calibrator is an essential tool in clinical diagnostics, particularly for the accurate measurement of D-Dimer levels in human serum. D-Dimer is a fibrin degradation product, and its levels are crucial in diagnosing conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation. This calibrator ensures that diagnostic tests are precise and reliable, providing clinicians with the confidence they need to make informed decisions.

1. The D-Dimer Calibrator is characterized by its high precision and stability, ensuring consistent results across different batches and testing conditions. Its composition is carefully controlled to mimic human serum, making it an ideal reference material for diagnostic assays.
2. Structurally, the calibrator is composed of a specific concentration of D-Dimer, along with buffering agents and a preservative to maintain its integrity over time. The inclusion of human serum as the biological source ensures that it behaves similarly to actual patient samples during testing.
3. The primary use of the D-Dimer Calibrator is to calibrate diagnostic assays for D-Dimer levels in human serum. It is specifically designed to work with the D-Dimer detection kit from Changzhou Aifukang Biotechnology Co., Ltd., ensuring that the results are accurate and reliable for clinical decision-making.

The D-Dimer Calibrator, also known as the D-Dimer Standard or Reference Material, is a critical component in the accurate measurement of D-Dimer levels in human serum. Its precise composition and human serum source make it an indispensable tool for clinicians and laboratory technicians, ensuring that diagnostic tests are both reliable and consistent.

Main Features

The D-Dimer Calibrator offers high precision, stability, and compatibility with human serum, making it an essential tool for accurate D-Dimer level measurement in clinical diagnostics.

1. High Precision: The calibrator is formulated with a precise concentration of D-Dimer, ensuring that diagnostic tests yield accurate and reproducible results.
2. Stability: The inclusion of buffering agents and a preservative ensures that the calibrator remains stable over time, even under varying storage conditions.
3. Compatibility: The use of human serum as the biological source ensures that the calibrator behaves similarly to actual patient samples, reducing the risk of assay interference.
4. Ease of Use: The calibrator is designed to be easily integrated into existing diagnostic workflows, requiring minimal preparation and handling.
5. Reliability: Consistent performance across different batches and testing conditions ensures that clinicians can rely on the results for accurate diagnosis and treatment decisions.

The D-Dimer Calibrator stands out for its precision, stability, and compatibility with human serum. These features make it an indispensable tool in clinical diagnostics, ensuring that D-Dimer levels are measured accurately and reliably, ultimately aiding in the diagnosis and management of thrombotic disorders.

Clinical Applications

The D-Dimer Calibrator is widely used in clinical settings to ensure the accuracy of D-Dimer level measurements, which are critical in diagnosing thrombotic disorders such as deep vein thrombosis and pulmonary embolism.

1. Diagnosis of Thrombotic Disorders: The calibrator is essential in the accurate measurement of D-Dimer levels, which are elevated in conditions such as deep vein thrombosis and pulmonary embolism.
2. Monitoring Treatment Efficacy: By providing accurate D-Dimer measurements, the calibrator helps clinicians monitor the effectiveness of anticoagulant therapy in patients with thrombotic disorders.
3. Risk Assessment: Elevated D-Dimer levels are associated with an increased risk of thrombotic events, and the calibrator aids in assessing this risk in patients.
4. Research Applications: The calibrator is also used in research settings to study the role of D-Dimer in various pathological conditions, contributing to the development of new diagnostic and therapeutic strategies.
5. Quality Control: In clinical laboratories, the calibrator is used as a quality control material to ensure the accuracy and reliability of D-Dimer assays.

The D-Dimer Calibrator plays a crucial role in the clinical diagnosis and management of thrombotic disorders. Its ability to provide accurate and reliable D-Dimer measurements makes it an invaluable tool for clinicians, aiding in the diagnosis, treatment monitoring, and risk assessment of patients with thrombotic conditions.

Purchasing Guide

When purchasing the D-Dimer Calibrator, it is important to consider product specifications, types, budget, and intended use to ensure it meets your diagnostic needs.

1. Product Specifications: Ensure that the calibrator's concentration and composition match the requirements of your diagnostic assays. The D-Dimer concentration should be within the specified range (15.0±3.0 mg/L) for accurate calibration.
2. Product Types: There may be different types of D-Dimer calibrators available, such as liquid or lyophilized forms. Choose the type that best suits your laboratory's workflow and storage capabilities.
3. Budget Considerations: While cost is an important factor, it should not compromise the quality and reliability of the calibrator. Consider the long-term benefits of accurate diagnostics when making your purchase decision.
4. Intended Use: Ensure that the calibrator is compatible with your diagnostic kit, particularly if you are using the D-Dimer detection kit from Changzhou Aifukang Biotechnology Co., Ltd. This compatibility is crucial for achieving accurate and reliable results.

Purchasing the D-Dimer Calibrator requires careful consideration of product specifications, types, budget, and intended use. By selecting the right calibrator, you can ensure that your diagnostic assays are accurate and reliable, ultimately improving patient outcomes.

 Precautions

Proper handling, storage, and usage of the D-Dimer Calibrator are essential to ensure accurate results and maintain its integrity.

1. Storage Conditions: The calibrator should be stored at the recommended temperature to maintain its stability and effectiveness. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling: Always use clean, sterile equipment when handling the calibrator to prevent contamination. Follow the manufacturer's instructions for proper handling and preparation.
3. Usage: Ensure that the calibrator is used within its expiration date and that it is properly mixed before use. Do not use if there are signs of contamination or degradation.
4. Disposal: Dispose of any unused or expired calibrator according to local regulations and guidelines for biohazardous materials.
5. Training: Ensure that all personnel handling the calibrator are properly trained in its use and understand the importance of following the manufacturer's instructions.

The D-Dimer Calibrator requires careful handling, storage, and usage to ensure its effectiveness and accuracy. By following the recommended precautions, you can maintain the integrity of the calibrator and achieve reliable diagnostic results, ultimately supporting better patient care.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files