The D-Dimer Assay Kit (Immunoturbidimetric Method) is a diagnostic tool designed for the quantitative determination of D-Dimer levels in human plasma. It is widely used in clinical settings to aid in the diagnosis and monitoring of thrombotic disorders. The kit offers high sensitivity and specificity, making it a reliable choice for healthcare professionals.
1. The kit features a robust immunoturbidimetric method, ensuring accurate and reproducible results. It is designed for use with automated analyzers, providing convenience and efficiency in high-throughput laboratories.
2. The composition includes R1 and R2 reagents, each formulated with Tris buffer and preservatives. R2 specifically contains D-Dimer antibody latex, which is crucial for the detection process. Optional quality control materials are available to ensure the reliability of the assay.
3. The primary use of this kit is to detect D-Dimer levels in plasma, which is essential for diagnosing conditions such as venous thrombosis and disseminated intravascular coagulation. It also plays a critical role in monitoring the effectiveness of thrombolytic therapy.
The D-Dimer Assay Kit is a vital tool in modern diagnostics, offering precision and reliability. Its design and composition make it suitable for a wide range of clinical applications, ensuring that healthcare providers can make informed decisions based on accurate data.
The D-Dimer Assay Kit offers high sensitivity and specificity, making it an essential tool for diagnosing thrombotic disorders. It is compatible with automated analyzers, ensuring efficient and accurate results.
1. The kit utilizes an immunoturbidimetric method, which provides high sensitivity and specificity in detecting D-Dimer levels.
2. It is designed for use with automated analyzers, allowing for high-throughput testing in clinical laboratories.
3. The kit includes R1 and R2 reagents, each formulated with Tris buffer and preservatives, ensuring stability and reliability.
4. Optional quality control materials are available, providing an additional layer of assurance for the accuracy of the assay.
5. The kit is widely used in clinical settings to aid in the diagnosis and monitoring of thrombotic disorders, making it a versatile tool for healthcare professionals.
The D-Dimer Assay Kit stands out for its precision and reliability. Its compatibility with automated analyzers and comprehensive quality control options make it a preferred choice for clinical laboratories.
The D-Dimer Assay Kit is clinically used to diagnose and monitor thrombotic disorders, including venous thrombosis and disseminated intravascular coagulation. It is also used to monitor thrombolytic therapy.
1. The kit is essential for the exclusion of venous thrombosis, providing critical information for patient management.
2. It aids in the diagnosis of disseminated intravascular coagulation, a condition that requires prompt and accurate diagnosis.
3. The kit is used to monitor the effectiveness of thrombolytic therapy, ensuring that patients receive the appropriate treatment.
4. It is widely used in emergency settings to quickly assess the risk of thrombotic events.
5. The kit is also utilized in research settings to study the mechanisms of thrombotic disorders and develop new treatments.
The D-Dimer Assay Kit is a cornerstone in the clinical management of thrombotic disorders. Its applications span from emergency diagnostics to ongoing treatment monitoring, making it an indispensable tool in modern medicine.
When purchasing the D-Dimer Assay Kit, consider factors such as product specifications, types, budget, and intended use scenarios to ensure the best fit for your laboratory needs.
1. Product specifications: Ensure the kit meets the required sensitivity and specificity for your diagnostic needs.
2. Product types: Choose between standard and high-throughput kits based on your laboratory's volume and requirements.
3. Budget: Consider the cost-effectiveness of the kit, including any additional costs for quality control materials.
4. Use scenarios: Evaluate the kit's compatibility with your laboratory's existing equipment and workflows.
Selecting the right D-Dimer Assay Kit involves careful consideration of various factors. By focusing on specifications, types, budget, and use scenarios, you can ensure that the kit meets your laboratory's needs effectively.
Proper handling and storage of the D-Dimer Assay Kit are crucial to ensure accurate results. Follow all instructions carefully to avoid contamination and ensure the integrity of the reagents.
1. Always store the kit at the recommended temperature to maintain the stability of the reagents.
2. Avoid exposing the reagents to direct sunlight or extreme temperatures, as this can affect their performance.
3. Use sterile techniques when handling samples to prevent contamination, which can lead to inaccurate results.
4. Follow the manufacturer's instructions for reagent preparation and usage to ensure optimal performance.
5. Regularly check the expiration dates of the reagents and replace them as needed to maintain the accuracy of the assay.
Taking the necessary precautions when using the D-Dimer Assay Kit is essential for obtaining reliable results. Proper storage, handling, and adherence to instructions will help ensure the kit performs as intended, providing accurate data for clinical decision-making.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.