Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Assay Kit (Fluorescence Immunochromatography)
The D-Dimer Assay Kit consists of a test card, sample buffer, and ID chip. The test card includes a test strip and a plastic casing. The test strip is composed of a nitrocellulose membrane, absorbent paper, PVC backing, and other supporting materials. The nitrocellulose membrane is coated with D-Dimer monoclonal antibodies and rabbit IgG. The sample buffer contains fluorescently labeled D-Dimer monoclonal antibodies and fluorescently labeled anti-rabbit IgG, along with 0.1% Triton-100 surfactant and 0.9% NaN3 preservative.
Product English Name:
D-Dimer Assay Kit (Fluorescence Immunochromatography)
Alias:
D-Dimer Test Kit,Fluorescence D-Dimer Kit
Intended Use:
This kit is designed to measure the concentration of D-Dimer in human plasma. It is clinically used to exclude venous thrombosis, assist in the diagnosis of disseminated intravascular coagulation (DIC), and monitor thrombolytic therapy.
Product Introduction

The D-Dimer Assay Kit (Fluorescence Immunochromatography) is a sophisticated diagnostic tool used to detect D-Dimer levels in human plasma. It employs fluorescence immunochromatography, a highly sensitive and specific method, to provide accurate results. The kit is essential in clinical settings for diagnosing and monitoring conditions related to blood clotting disorders.

1. The kit features a unique fluorescence immunochromatography technology, ensuring high sensitivity and specificity in detecting D-Dimer levels. This method allows for rapid and reliable results, making it a preferred choice in clinical diagnostics.
2. The test card is composed of a nitrocellulose membrane, absorbent paper, PVC backing, and other supporting materials. The nitrocellulose membrane is coated with D-Dimer monoclonal antibodies and rabbit IgG, which are crucial for the accurate detection of D-Dimer.
3. The kit is primarily used to measure D-Dimer levels in human plasma, aiding in the exclusion of venous thrombosis, diagnosis of disseminated intravascular coagulation (DIC), and monitoring of thrombolytic therapy. Its clinical applications are vital for managing patients with blood clotting disorders.

The D-Dimer Assay Kit, also known as the Fluorescence D-Dimer Kit, is a critical diagnostic tool in modern medicine. Its advanced fluorescence immunochromatography technology ensures precise detection of D-Dimer levels, making it indispensable in clinical settings. The kit's components, including the test card and sample buffer, are meticulously designed to provide accurate and reliable results, aiding in the diagnosis and monitoring of blood clotting disorders.

Main Features

The D-Dimer Assay Kit offers high sensitivity and specificity in detecting D-Dimer levels, utilizing fluorescence immunochromatography for rapid and reliable results.

1. The kit employs fluorescence immunochromatography, a highly sensitive and specific method for detecting D-Dimer levels, ensuring accurate and reliable results.
2. The test card is designed with a nitrocellulose membrane coated with D-Dimer monoclonal antibodies and rabbit IgG, which are essential for precise detection.
3. The sample buffer contains fluorescently labeled D-Dimer monoclonal antibodies and anti-rabbit IgG, along with surfactants and preservatives, ensuring stability and accuracy.
4. The kit provides rapid results, making it suitable for urgent clinical situations where quick diagnosis is crucial.
5. It is easy to use, with a straightforward procedure that can be performed by healthcare professionals with minimal training.

The D-Dimer Assay Kit stands out for its high sensitivity, specificity, and ease of use. Its fluorescence immunochromatography technology ensures rapid and accurate detection of D-Dimer levels, making it a valuable tool in clinical diagnostics. The kit's design and components are optimized for reliability and ease of use, making it a preferred choice for healthcare professionals.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings to diagnose and monitor conditions related to blood clotting disorders, such as venous thrombosis and disseminated intravascular coagulation (DIC).

1. The kit is used to exclude venous thrombosis by measuring D-Dimer levels in patients with suspected blood clotting disorders.
2. It assists in the diagnosis of disseminated intravascular coagulation (DIC), a serious condition characterized by widespread blood clotting.
3. The kit is used to monitor thrombolytic therapy, ensuring that the treatment is effective and adjusting it as necessary.
4. It is also used in the diagnosis of pulmonary embolism, a condition where blood clots block the arteries in the lungs.
5. The kit is valuable in managing patients with deep vein thrombosis (DVT), helping to prevent complications such as pulmonary embolism.

The D-Dimer Assay Kit is a versatile tool in clinical practice, essential for diagnosing and monitoring blood clotting disorders. Its applications range from excluding venous thrombosis to assisting in the diagnosis of DIC and monitoring thrombolytic therapy. The kit's reliability and accuracy make it a trusted choice for healthcare professionals managing patients with complex clotting disorders.

Purchasing Guide

When purchasing the D-Dimer Assay Kit, consider product specifications, types, budget, and intended use to ensure it meets your clinical needs.

1. Evaluate the product specifications, including sensitivity, specificity, and detection range, to ensure it meets your diagnostic requirements.
2. Consider the types of kits available, such as those with different detection methods or formats, to choose the one that best fits your clinical setting.
3. Assess your budget and compare prices from different suppliers to find a cost-effective solution without compromising quality.
4. Determine the intended use of the kit, whether for routine diagnostics, emergency situations, or specialized clinical applications, to ensure it aligns with your needs.

Purchasing the D-Dimer Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can select a kit that meets your clinical needs and provides reliable and accurate results. It's essential to choose a kit that aligns with your diagnostic requirements and fits within your budget, ensuring optimal performance in your clinical setting.

 Precautions

Proper handling and storage of the D-Dimer Assay Kit are crucial to ensure accurate results and maintain the integrity of the components.

1. Store the kit at the recommended temperature to prevent degradation of the components and ensure accurate results.
2. Handle the test cards and sample buffer with care to avoid contamination, which could affect the accuracy of the test.
3. Follow the manufacturer's instructions for use, including proper sample preparation and handling, to ensure reliable results.
4. Dispose of used components according to biohazard waste disposal guidelines to prevent contamination and ensure safety.
5. Regularly calibrate and maintain the equipment used with the kit to ensure consistent performance and accuracy.

The D-Dimer Assay Kit requires careful handling and storage to maintain its integrity and ensure accurate results. Proper storage, handling, and disposal of components are essential to prevent contamination and ensure the reliability of the test. Following the manufacturer's instructions and maintaining equipment are crucial steps in achieving consistent and accurate results in clinical diagnostics.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files