Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer (DD) Assay Kit (Latex Immunoturbidimetric Method)
The D-Dimer (DD) Assay Kit is composed of two main reagents: Reagent 1 and Reagent 2. Each reagent contains Tris Ultra Pure, Hydrochloric Acid, 1-Oxo-2-Hydroxypyridine (HPO), Sodium Chloride, Polyethylene Glycol Ester (Thesit), Bovine Serum Albumin (BSA firv), and Horse Serum (Carbon Adsorbed). These components are carefully balanced to ensure accurate and reliable results in the quantitative determination of D-Dimer levels in human plasma.
Product English Name:
D-Dimer (DD) Assay Kit (Latex Immunoturbidimetric Method)
Alias:
D-Dimer Test Kit,DD Assay Kit
Intended Use:
This kit is specifically designed for the in vitro quantitative determination of D-Dimer levels in human plasma. It is widely used in clinical settings to aid in the diagnosis and monitoring of conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
Product Introduction

The D-Dimer (DD) Assay Kit (Latex Immunoturbidimetric Method) is a sophisticated diagnostic tool used to measure the concentration of D-Dimer in human plasma. D-Dimer is a fibrin degradation product that is typically elevated in patients with thrombotic disorders. This kit employs a latex immunoturbidimetric method, which is known for its high sensitivity and specificity. The assay is easy to perform and provides rapid results, making it an essential tool in clinical laboratories.

1. The D-Dimer Assay Kit is characterized by its high sensitivity and specificity, ensuring accurate detection of D-Dimer levels even at low concentrations. The latex immunoturbidimetric method used in this kit enhances the precision of the assay, making it a reliable choice for clinical diagnostics.
2. The kit consists of two main reagents, each containing a balanced mixture of Tris Ultra Pure, Hydrochloric Acid, 1-Oxo-2-Hydroxypyridine (HPO), Sodium Chloride, Polyethylene Glycol Ester (Thesit), Bovine Serum Albumin (BSA firv), and Horse Serum (Carbon Adsorbed). These components work synergistically to ensure the stability and accuracy of the assay.
3. The primary use of the D-Dimer Assay Kit is in the diagnosis and monitoring of thrombotic disorders such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation. The kit provides quantitative results that are crucial for clinical decision-making and patient management.

The D-Dimer (DD) Assay Kit, also known as the DD Assay Kit, is a vital diagnostic tool in the clinical setting. Its high sensitivity and specificity, combined with its ease of use, make it an indispensable resource for healthcare professionals. The kit's composition is meticulously designed to ensure accurate and reliable results, aiding in the effective diagnosis and management of thrombotic disorders.

Main Features

The D-Dimer Assay Kit offers high sensitivity and specificity, rapid results, and ease of use, making it a preferred choice for clinical laboratories.

1. High Sensitivity: The kit is capable of detecting low concentrations of D-Dimer, ensuring accurate diagnosis even in early stages of thrombotic disorders.
2. High Specificity: The latex immunoturbidimetric method minimizes cross-reactivity, providing reliable results that are specific to D-Dimer.
3. Rapid Results: The assay provides results quickly, allowing for timely clinical decision-making and patient management.
4. Ease of Use: The kit is designed for simplicity, with straightforward procedures that can be easily performed by laboratory personnel.
5. Stability: The reagents are formulated to maintain stability over time, ensuring consistent performance and reliable results.

The D-Dimer Assay Kit stands out for its high sensitivity, specificity, and rapid results. Its ease of use and stability make it a reliable tool for clinical laboratories, aiding in the accurate diagnosis and management of thrombotic disorders.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic disorders, including deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.

1. Deep Vein Thrombosis (DVT): The kit is used to detect elevated D-Dimer levels, which are indicative of DVT, aiding in early diagnosis and treatment.
2. Pulmonary Embolism (PE): Elevated D-Dimer levels are also associated with PE, and the kit provides crucial diagnostic information for this condition.
3. Disseminated Intravascular Coagulation (DIC): The kit is used to monitor D-Dimer levels in patients with DIC, helping to guide treatment decisions.
4. Post-Surgical Monitoring: The kit is used to monitor D-Dimer levels in patients post-surgery to detect any thrombotic complications.
5. General Thrombosis Screening: The kit is also used for general screening of thrombotic disorders in high-risk patients.

The D-Dimer Assay Kit is an essential tool in the clinical diagnosis and monitoring of thrombotic disorders. Its ability to provide rapid and accurate results makes it invaluable in managing conditions such as DVT, PE, and DIC, as well as in post-surgical monitoring and general thrombosis screening.

Purchasing Guide

When purchasing the D-Dimer Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure the best fit for your clinical laboratory.

1. Product Specifications: Ensure that the kit meets the required sensitivity, specificity, and stability standards for your laboratory's needs.
2. Product Types: Choose between different formats or sizes of the kit based on the volume of tests your laboratory performs.
3. Budget: Consider the cost-effectiveness of the kit, including the price per test and any additional costs for reagents or equipment.
4. Intended Use: Select a kit that is specifically designed for the types of thrombotic disorders you commonly diagnose and monitor.

Purchasing the D-Dimer Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By selecting the right kit for your laboratory's needs, you can ensure accurate and reliable diagnostic results.

 Precautions

Proper handling and storage of the D-Dimer Assay Kit are essential to ensure accurate results and maintain the integrity of the reagents.

1. Storage Conditions: Store the kit at the recommended temperature to maintain the stability and effectiveness of the reagents.
2. Handling: Follow proper laboratory procedures when handling the kit to avoid contamination and ensure accurate results.
3. Expiration Date: Always check the expiration date before use and do not use expired reagents.
4. Calibration: Regularly calibrate the equipment used with the kit to ensure consistent and accurate results.
5. Disposal: Dispose of used reagents and materials according to local regulations and laboratory protocols.

To ensure the accuracy and reliability of the D-Dimer Assay Kit, it is crucial to follow proper storage, handling, and disposal procedures. Regular calibration and adherence to expiration dates are also essential to maintain the integrity of the assay.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files