D-Dimer Assay Kit (Fluorescence Immunochromatography)
The D-Dimer Assay Kit is composed of a reagent card, buffer solution, ID chip, and user manual. The reagent card includes a test strip and a plastic casing. The test strip is made of nitrocellulose membrane, absorbent paper, PVC board, and other supporting materials. The nitrocellulose membrane is coated with D-Dimer monoclonal antibodies and chicken IgY. The labeling pad contains fluorescently labeled D-Dimer monoclonal antibodies and fluorescently labeled goat anti-chicken IgY.
Product English Name:
D-Dimer Assay Kit (Fluorescence Immunochromatography)
Alias:
D-Dimer Test Kit,Fluorescent D-Dimer Assay
Intended Use:
This kit is designed for the quantitative detection of D-Dimer concentration in human whole blood or plasma samples. It is primarily used in clinical settings for monitoring thrombolytic therapy. However, it is not suitable for the exclusion diagnosis of venous thrombosis.
Product Introduction

The D-Dimer Assay Kit (Fluorescence Immunochromatography) is a cutting-edge diagnostic tool designed for the precise measurement of D-Dimer levels in human blood. Utilizing advanced fluorescence immunochromatography technology, this kit offers high sensitivity and specificity, making it an essential tool in clinical diagnostics, particularly in the monitoring of thrombolytic therapy.

1. The kit features a unique reagent card that includes a test strip and a plastic casing. The test strip is composed of a nitrocellulose membrane, absorbent paper, PVC board, and other supporting materials. The nitrocellulose membrane is coated with D-Dimer monoclonal antibodies and chicken IgY, ensuring accurate detection.
2. The labeling pad contains fluorescently labeled D-Dimer monoclonal antibodies and fluorescently labeled goat anti-chicken IgY. This combination allows for the precise quantification of D-Dimer levels in blood samples, providing reliable results for clinical decision-making.
3. The kit is specifically designed for the quantitative detection of D-Dimer concentration in human whole blood or plasma samples. It is widely used in clinical settings for monitoring thrombolytic therapy, aiding in the management of patients undergoing such treatments.

The D-Dimer Assay Kit, also known as the Fluorescent D-Dimer Assay, is a vital tool in modern clinical diagnostics. Its unique composition and advanced technology make it an indispensable resource for healthcare professionals, particularly in the monitoring of thrombolytic therapy. The kit's precision and reliability ensure accurate results, contributing to better patient outcomes.

Main Features

The D-Dimer Assay Kit offers high sensitivity and specificity in detecting D-Dimer levels, making it a reliable tool for clinical diagnostics.

1. The kit utilizes fluorescence immunochromatography technology, ensuring high sensitivity and specificity in detecting D-Dimer levels.
2. The reagent card is designed for easy use, with a test strip and plastic casing that ensure accurate and reliable results.
3. The labeling pad contains fluorescently labeled antibodies, allowing for precise quantification of D-Dimer levels in blood samples.
4. The kit is designed for the quantitative detection of D-Dimer concentration in human whole blood or plasma samples, making it suitable for clinical use.
5. The kit is widely used in clinical settings for monitoring thrombolytic therapy, aiding in the management of patients undergoing such treatments.

The D-Dimer Assay Kit stands out for its high sensitivity and specificity, making it a reliable tool for clinical diagnostics. Its advanced technology and user-friendly design ensure accurate results, contributing to better patient outcomes.

Clinical Applications

The D-Dimer Assay Kit is primarily used in clinical settings for monitoring thrombolytic therapy, providing reliable results for patient management.

1. The kit is widely used in clinical settings for monitoring thrombolytic therapy, aiding in the management of patients undergoing such treatments.
2. It is also used in the diagnosis of conditions related to abnormal blood clotting, providing valuable information for clinical decision-making.
3. The kit's high sensitivity and specificity make it a reliable tool for detecting D-Dimer levels in blood samples, ensuring accurate results.
4. The kit is used in various clinical settings, including hospitals and diagnostic laboratories, for the quantitative detection of D-Dimer levels.
5. The kit is particularly useful in the management of patients with conditions related to abnormal blood clotting, providing reliable results for clinical decision-making.

The D-Dimer Assay Kit is a valuable tool in clinical settings, particularly for monitoring thrombolytic therapy. Its high sensitivity and specificity ensure accurate results, contributing to better patient outcomes.

Purchasing Guide

The D-Dimer Assay Kit is designed for easy use, with a focus on providing accurate and reliable results in clinical settings.

1. The kit includes a reagent card, buffer solution, ID chip, and user manual, ensuring easy and accurate use.
2. The kit is available in various types, including single-use and multi-use options, catering to different clinical needs.
3. The kit is designed to fit within various procurement budgets, making it accessible to a wide range of healthcare facilities.
4. The kit is suitable for use in various clinical settings, including hospitals and diagnostic laboratories, ensuring its versatility.

The D-Dimer Assay Kit is designed for easy use and accessibility, making it a valuable tool in various clinical settings. Its versatility and reliability ensure accurate results, contributing to better patient outcomes.

 Precautions

Proper handling and storage of the D-Dimer Assay Kit are essential to ensure accurate results and maintain the integrity of the kit.

1. The kit should be stored at the recommended temperature to maintain its effectiveness and ensure accurate results.
2. Proper handling of the reagent card and buffer solution is essential to avoid contamination and ensure accurate results.
3. The kit should be used within its expiration date to ensure the reliability of the results.
4. Proper disposal of used materials is essential to maintain a safe and clean laboratory environment.
5. The kit should be used by trained professionals to ensure accurate results and proper handling.

Proper handling and storage of the D-Dimer Assay Kit are essential to ensure accurate results and maintain the integrity of the kit. Following the recommended guidelines and using the kit within its expiration date will ensure reliable results and contribute to better patient outcomes.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files