Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Assay Kit (Latex-Enhanced Immunoturbidimetric Method)
The D-Dimer Assay Kit consists of two main components: R1, which includes a phosphate buffer (60 mmol/L) and polyethylene glycol 6000 (2.20%), and R2, which contains a phosphate buffer (60 mmol/L) and D-Dimer monoclonal antibody-sensitized latex particles (0.26 g/L). This kit is designed for the quantitative determination of D-Dimer levels in human serum, providing a reliable tool for clinical diagnostics.
Product English Name:
D-Dimer Assay Kit (Latex-Enhanced Immunoturbidimetric Method)
Alias:
D-Dimer Test Kit,D-Dimer Quantitative Kit
Intended Use:
This kit is specifically designed for the in vitro quantitative determination of D-Dimer levels in human serum. It is widely used in clinical settings to aid in the diagnosis and monitoring of conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
Product Introduction

The D-Dimer Assay Kit is a state-of-the-art diagnostic tool designed for the accurate and reliable measurement of D-Dimer levels in human serum. Utilizing the latex-enhanced immunoturbidimetric method, this kit offers high sensitivity and specificity, making it an essential component in the clinical assessment of thrombotic disorders. The kit's robust design ensures consistent performance, even in high-throughput laboratory environments.

1. The D-Dimer Assay Kit is characterized by its high sensitivity and specificity, which are critical for the accurate detection of D-Dimer levels. The latex-enhanced immunoturbidimetric method ensures that even low concentrations of D-Dimer can be reliably measured, providing clinicians with valuable diagnostic information.
2. The kit is composed of two main reagents: R1, which contains a phosphate buffer and polyethylene glycol 6000, and R2, which includes a phosphate buffer and D-Dimer monoclonal antibody-sensitized latex particles. These components work in tandem to ensure the accurate and precise measurement of D-Dimer levels in serum samples.
3. The primary use of the D-Dimer Assay Kit is in the clinical diagnosis and monitoring of thrombotic disorders. By providing a quantitative measure of D-Dimer levels, this kit aids in the assessment of conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation, enabling timely and effective treatment decisions.

The D-Dimer Assay Kit, also known as the D-Dimer Test Kit or D-Dimer Quantitative Kit, is a vital tool in the clinical diagnosis of thrombotic disorders. Its high sensitivity and specificity, combined with its robust design, make it an indispensable resource for healthcare professionals. Whether you're diagnosing deep vein thrombosis or monitoring the effectiveness of treatment, this kit provides the accuracy and reliability you need.

Main Features

The D-Dimer Assay Kit offers high sensitivity and specificity, ensuring accurate detection of D-Dimer levels. Its latex-enhanced immunoturbidimetric method provides reliable results, even at low concentrations.

1. High Sensitivity: The kit is designed to detect even low concentrations of D-Dimer, ensuring accurate diagnosis of thrombotic disorders.
2. Specificity: The use of D-Dimer monoclonal antibody-sensitized latex particles ensures that the kit specifically targets D-Dimer, reducing the risk of false positives.
3. Robust Design: The kit's components are stable and reliable, ensuring consistent performance in various laboratory conditions.
4. Ease of Use: The kit is designed for straightforward operation, making it accessible to a wide range of healthcare professionals.
5. High Throughput: The kit is suitable for use in high-throughput laboratories, allowing for the efficient processing of large numbers of samples.

The D-Dimer Assay Kit stands out for its high sensitivity, specificity, and robust design. Whether you're working in a high-throughput lab or a smaller clinical setting, this kit provides the accuracy and reliability you need to make informed diagnostic decisions.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic disorders, including deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.

1. Deep Vein Thrombosis (DVT): The kit is used to measure D-Dimer levels in patients suspected of having DVT, aiding in the diagnosis and monitoring of the condition.
2. Pulmonary Embolism (PE): Elevated D-Dimer levels are a key indicator of PE, and the kit is used to confirm the diagnosis and monitor treatment effectiveness.
3. Disseminated Intravascular Coagulation (DIC): The kit is used to assess D-Dimer levels in patients with DIC, providing critical information for treatment decisions.
4. Post-Surgical Monitoring: The kit is used to monitor D-Dimer levels in patients post-surgery to detect any thrombotic complications.
5. General Thrombosis Screening: The kit is also used for general screening of thrombotic disorders in high-risk patients, providing early detection and intervention.

The D-Dimer Assay Kit is a versatile tool in the clinical setting, used for the diagnosis and monitoring of various thrombotic disorders. Its ability to provide accurate and reliable D-Dimer measurements makes it an essential resource for healthcare professionals.

Purchasing Guide

When purchasing the D-Dimer Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure you select the right kit for your needs.

1. Product Specifications: Ensure the kit meets your laboratory's requirements in terms of sensitivity, specificity, and throughput.
2. Product Types: Choose between different kit formats (e.g., single-use vs. multi-use) based on your laboratory's workflow and sample volume.
3. Budget: Consider the cost of the kit, including any additional reagents or equipment needed, to ensure it fits within your budget.
4. Intended Use: Select a kit that is specifically designed for the clinical applications you intend to use it for, such as DVT or PE diagnosis.

Selecting the right D-Dimer Assay Kit involves careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that you choose a kit that meets your laboratory's needs and provides reliable results.

 Precautions

When using the D-Dimer Assay Kit, it is important to follow proper handling and storage procedures to ensure accurate results and maintain the integrity of the kit.

1. Proper Storage: Store the kit at the recommended temperature to maintain the stability of the reagents.
2. Handling: Follow proper handling procedures to avoid contamination and ensure accurate results.
3. Calibration: Regularly calibrate the equipment used with the kit to ensure consistent performance.
4. Sample Preparation: Ensure that serum samples are properly prepared and handled to avoid errors in D-Dimer measurement.
5. Disposal: Dispose of used reagents and samples according to local regulations to ensure safety and environmental compliance.

Using the D-Dimer Assay Kit requires attention to detail, from proper storage and handling to calibration and disposal. By following these precautions, you can ensure the accuracy and reliability of your results while maintaining a safe and compliant laboratory environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list