The D-Dimer Assay Kit (Immunoturbidimetric Method) is a sophisticated diagnostic tool designed for the quantitative determination of D-Dimer levels in human plasma. This kit is essential in clinical laboratories for assessing conditions related to coagulation and fibrinolysis. It offers high sensitivity and specificity, making it a reliable choice for healthcare professionals.
1. The D-Dimer Assay Kit is characterized by its high precision and accuracy, ensuring reliable results in clinical diagnostics. It utilizes an immunoturbidimetric method, which is known for its robustness and ease of use in laboratory settings.
2. The kit is composed of Reagent R1, Reagent R2, and an optional calibrator. These components are carefully formulated to interact with D-Dimer in plasma, producing a measurable turbidity change that correlates with D-Dimer concentration.
3. The primary use of this kit is to measure D-Dimer levels in human plasma, which is crucial for diagnosing and monitoring conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
The D-Dimer Assay Kit, also known as the D-Dimer Test Kit, is a vital tool in clinical diagnostics. Its high precision and robust composition make it indispensable for measuring D-Dimer levels, aiding in the diagnosis and monitoring of various coagulation disorders.
The D-Dimer Assay Kit offers high sensitivity and specificity for detecting D-Dimer levels in plasma. It is designed for ease of use in clinical laboratories, providing reliable and accurate results.
1. The kit employs an immunoturbidimetric method, which is highly sensitive and specific for D-Dimer detection, ensuring accurate results.
2. It includes Reagent R1 and R2, which are optimized for precise interaction with D-Dimer, producing a measurable turbidity change.
3. The optional calibrator allows for standardization of measurements, enhancing the reliability of the results.
4. The kit is designed for high-throughput laboratories, enabling efficient processing of multiple samples.
5. It is compatible with a wide range of automated analyzers, making it versatile for various laboratory setups.
The D-Dimer Assay Kit stands out for its high sensitivity, specificity, and ease of use. Its robust design and compatibility with automated systems make it a preferred choice for clinical laboratories.
The D-Dimer Assay Kit is widely used in clinical settings for diagnosing and monitoring conditions related to blood clotting and fibrinolysis. It is particularly useful in emergency and critical care settings.
1. The kit is used in the diagnosis of deep vein thrombosis (DVT), providing critical information for patient management.
2. It is also employed in the assessment of pulmonary embolism (PE), aiding in the rapid diagnosis of this life-threatening condition.
3. The kit is useful in monitoring disseminated intravascular coagulation (DIC), a complex condition that requires precise diagnostic tools.
4. It is used in research settings to study the mechanisms of coagulation and fibrinolysis, contributing to the development of new therapies.
5. The kit is also applied in routine health check-ups to assess the risk of thrombotic events in patients with predisposing conditions.
The D-Dimer Assay Kit is a versatile tool in clinical diagnostics, essential for the diagnosis and monitoring of various coagulation disorders. Its application in both clinical and research settings underscores its importance in modern medicine.
When purchasing the D-Dimer Assay Kit, it is important to consider product specifications, types, budget, and intended use to ensure it meets your laboratory's needs.
1. Product parameters such as sensitivity, specificity, and compatibility with analyzers should be evaluated to ensure the kit meets your diagnostic requirements.
2. Different types of kits may be available, including those with or without calibrators. Choose the type that best fits your laboratory's workflow and needs.
3. Budget considerations are crucial. Ensure that the kit provides good value for money, balancing cost with performance and reliability.
4. Consider the intended use of the kit, whether for routine diagnostics, emergency care, or research, to ensure it aligns with your laboratory's objectives.
Purchasing the D-Dimer Assay Kit requires careful consideration of various factors to ensure it meets your laboratory's needs. By evaluating product parameters, types, budget, and intended use, you can make an informed decision that enhances your diagnostic capabilities.
Proper handling and storage of the D-Dimer Assay Kit are essential to ensure accurate results and maintain the integrity of the reagents.
1. Always follow the manufacturer's instructions for storage and handling to prevent degradation of the reagents.
2. Ensure that all components are stored at the recommended temperature and protected from light to maintain their efficacy.
3. Use the kit within its expiration date to avoid unreliable results. Check the expiration date before use.
4. Properly calibrate the analyzer and perform regular quality control checks to ensure the accuracy of the results.
5. Dispose of used reagents and samples according to local regulations and laboratory safety protocols to prevent contamination and ensure safety.
Adhering to proper handling and storage protocols is crucial for the effective use of the D-Dimer Assay Kit. By following these precautions, you can ensure the reliability and accuracy of your diagnostic results, maintaining the highest standards of laboratory practice.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.