Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Assay Kit (Latex-Enhanced Turbidimetric Method)
The D-Dimer Assay Kit consists of two main reagents: R1 and R2. R1 contains phosphate buffer, PEG6000, and acetamide, while R2 includes phosphate buffer, PEG6000, and latex particles sensitized with mouse anti-human D-Dimer antibodies. Additionally, the kit includes a calibrator made of bovine serum albumin, phosphate buffer, D-Dimer, NaCl, Tween 20, sucrose, and Proclin300. This composition ensures accurate and reliable detection of D-Dimer levels in human plasma.
Product English Name:
D-Dimer Assay Kit (Latex-Enhanced Turbidimetric Method)
Alias:
D-Dimer Test Kit,Fibrin Degradation Product Assay Kit
Intended Use:
The D-Dimer Assay Kit is designed to measure the concentration of D-Dimer in human plasma. It is clinically used to exclude venous thromboembolism, assist in diagnosing disseminated intravascular coagulation (DIC), and monitor thrombolytic therapy. Its high sensitivity and specificity make it a valuable tool in clinical diagnostics.
Product Introduction

The D-Dimer Assay Kit (Latex-Enhanced Turbidimetric Method) is a cutting-edge diagnostic tool designed for the quantitative determination of D-Dimer levels in human plasma. This kit is widely used in clinical settings to aid in the diagnosis and monitoring of thrombotic disorders. Its advanced latex-enhanced turbidimetric method ensures high accuracy and reliability, making it an essential tool for healthcare professionals.

1. The D-Dimer Assay Kit features a latex-enhanced turbidimetric method, which enhances sensitivity and specificity. This method allows for the precise detection of D-Dimer levels, even at low concentrations, ensuring reliable results in clinical diagnostics.
2. The kit is composed of two main reagents: R1 and R2. R1 contains phosphate buffer, PEG6000, and acetamide, while R2 includes phosphate buffer, PEG6000, and latex particles sensitized with mouse anti-human D-Dimer antibodies. The calibrator, made of bovine serum albumin, phosphate buffer, D-Dimer, NaCl, Tween 20, sucrose, and Proclin300, ensures accurate calibration and consistent results.
3. The primary use of the D-Dimer Assay Kit is to measure D-Dimer levels in human plasma. It is clinically employed to exclude venous thromboembolism, assist in diagnosing disseminated intravascular coagulation (DIC), and monitor thrombolytic therapy. Its high sensitivity and specificity make it a valuable tool in clinical diagnostics.

The D-Dimer Assay Kit, also known as the Fibrin Degradation Product Assay Kit, is a highly reliable diagnostic tool used to measure D-Dimer levels in human plasma. Its advanced latex-enhanced turbidimetric method ensures accurate and consistent results, making it an essential tool for healthcare professionals in diagnosing and monitoring thrombotic disorders.

Main Features

The D-Dimer Assay Kit offers high sensitivity and specificity in detecting D-Dimer levels. Its latex-enhanced turbidimetric method ensures precise and reliable results, making it a valuable tool in clinical diagnostics.

1. The kit utilizes a latex-enhanced turbidimetric method, which enhances the sensitivity and specificity of D-Dimer detection. This method allows for the precise measurement of D-Dimer levels, even at low concentrations.
2. The kit includes two main reagents: R1 and R2. R1 contains phosphate buffer, PEG6000, and acetamide, while R2 includes phosphate buffer, PEG6000, and latex particles sensitized with mouse anti-human D-Dimer antibodies. These components work together to ensure accurate and reliable results.
3. The kit also includes a calibrator made of bovine serum albumin, phosphate buffer, D-Dimer, NaCl, Tween 20, sucrose, and Proclin300. This calibrator ensures consistent and accurate calibration, leading to reliable results.
4. The D-Dimer Assay Kit is designed for use in clinical settings to measure D-Dimer levels in human plasma. It is particularly useful in excluding venous thromboembolism, diagnosing disseminated intravascular coagulation (DIC), and monitoring thrombolytic therapy.
5. The kit's high sensitivity and specificity make it a valuable tool for healthcare professionals. Its advanced method ensures that even low concentrations of D-Dimer can be detected, providing reliable results for clinical diagnostics.

The D-Dimer Assay Kit is a highly sensitive and specific diagnostic tool that utilizes a latex-enhanced turbidimetric method to detect D-Dimer levels in human plasma. Its advanced features and reliable results make it an essential tool for healthcare professionals in diagnosing and monitoring thrombotic disorders.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings to aid in the diagnosis and monitoring of thrombotic disorders. Its high sensitivity and specificity make it a valuable tool for healthcare professionals.

1. The D-Dimer Assay Kit is used to exclude venous thromboembolism (VTE) in patients with suspected deep vein thrombosis (DVT) or pulmonary embolism (PE). Its high sensitivity ensures that negative results can reliably exclude VTE.
2. The kit is also used in the diagnosis of disseminated intravascular coagulation (DIC). Elevated D-Dimer levels are a key indicator of DIC, and the kit's high specificity ensures accurate diagnosis.
3. The D-Dimer Assay Kit is employed in monitoring thrombolytic therapy. By measuring D-Dimer levels, healthcare professionals can assess the effectiveness of thrombolytic treatment and adjust therapy as needed.
4. The kit is used in the diagnosis of other thrombotic disorders, such as arterial thrombosis and thrombotic microangiopathy. Its high sensitivity and specificity make it a valuable tool in these clinical applications.
5. The D-Dimer Assay Kit is also used in research settings to study the role of D-Dimer in various thrombotic and inflammatory conditions. Its reliable results make it a valuable tool for researchers.

The D-Dimer Assay Kit is a versatile diagnostic tool used in various clinical applications, including the exclusion of venous thromboembolism, diagnosis of disseminated intravascular coagulation, and monitoring of thrombolytic therapy. Its high sensitivity and specificity make it an essential tool for healthcare professionals.

Purchasing Guide

When purchasing the D-Dimer Assay Kit, it is important to consider product parameters, types, budget, and usage scenarios to ensure the best fit for your clinical needs.

1. Product Parameters: Consider the sensitivity, specificity, and detection range of the D-Dimer Assay Kit. Ensure that the kit meets the required standards for clinical diagnostics.
2. Product Types: There are different types of D-Dimer Assay Kits available, including those for different sample types (e.g., plasma, serum) and detection methods (e.g., turbidimetric, ELISA). Choose the type that best suits your clinical needs.
3. Purchase Budget: Determine your budget for the D-Dimer Assay Kit. Consider the cost per test and the overall cost of the kit, including any additional reagents or equipment needed.
4. Usage Scenarios: Consider the specific clinical scenarios in which the D-Dimer Assay Kit will be used. Ensure that the kit is suitable for the intended applications, such as excluding venous thromboembolism or diagnosing disseminated intravascular coagulation.

When purchasing the D-Dimer Assay Kit, it is important to carefully consider product parameters, types, budget, and usage scenarios to ensure that the kit meets your clinical needs. By doing so, you can ensure that you are getting the best value and performance for your investment.

 Precautions

When using the D-Dimer Assay Kit, it is important to follow the manufacturer's instructions and take necessary precautions to ensure accurate and reliable results.

1. Always use the D-Dimer Assay Kit within its expiration date. Using expired reagents can lead to inaccurate results.
2. Ensure that all reagents are stored at the recommended temperature. Improper storage can affect the performance of the kit.
3. Follow the manufacturer's instructions for sample preparation and handling. Improper sample handling can lead to inaccurate results.
4. Use the calibrator provided with the kit to ensure accurate calibration. Using a different calibrator can lead to inaccurate results.
5. Regularly perform quality control tests to ensure the accuracy and reliability of the D-Dimer Assay Kit. This will help identify any potential issues with the kit.

Using the D-Dimer Assay Kit requires careful attention to detail and adherence to the manufacturer's instructions. By following the recommended precautions, you can ensure accurate and reliable results, making the kit a valuable tool in clinical diagnostics.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files