Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Assay Kit (Latex-Enhanced Immunoturbidimetric Method)
The D-Dimer Assay Kit consists of two main components: R1, which includes phosphate buffer and surfactant, and R2, which contains phosphate buffer, surfactant, and latex particles sensitized with mouse anti-human D-D monoclonal antibodies. This composition ensures accurate and reliable measurement of D-Dimer levels in human plasma.
Product English Name:
D-Dimer Assay Kit (Latex-Enhanced Immunoturbidimetric Method)
Alias:
D-Dimer Test Kit,D-Dimer Quantitative Kit
Intended Use:
This kit is designed for the in vitro quantitative determination of D-Dimer levels in human plasma. It serves as an auxiliary diagnostic tool, aiding in the detection and monitoring of conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
Product Introduction

The D-Dimer Assay Kit is a sophisticated diagnostic tool used to measure the concentration of D-Dimer in human plasma. Utilizing the latex-enhanced immunoturbidimetric method, this kit offers high sensitivity and specificity, making it an essential component in clinical laboratories. It is particularly useful in the diagnosis and management of thrombotic disorders, providing clinicians with critical information to guide patient care.

1. The D-Dimer Assay Kit is characterized by its high sensitivity and specificity, ensuring accurate detection of D-Dimer levels even at low concentrations. The use of latex particles enhances the turbidimetric measurement, providing a robust and reliable assay.
2. The kit is composed of two main reagents: R1, which contains phosphate buffer and surfactant, and R2, which includes phosphate buffer, surfactant, and latex particles sensitized with mouse anti-human D-D monoclonal antibodies. This combination ensures optimal performance and stability.
3. The primary use of the D-Dimer Assay Kit is for the quantitative determination of D-Dimer in human plasma. It is widely used in clinical settings to aid in the diagnosis of thrombotic conditions, such as deep vein thrombosis and pulmonary embolism, as well as in monitoring the effectiveness of anticoagulant therapy.

The D-Dimer Assay Kit, also known as the D-Dimer Test Kit, is a vital tool in clinical diagnostics. Its high sensitivity and specificity, combined with its robust composition, make it an indispensable resource for clinicians. Whether used for diagnosing thrombotic disorders or monitoring treatment efficacy, this kit provides reliable and accurate results, ensuring optimal patient care.

Main Features

The D-Dimer Assay Kit offers high sensitivity and specificity, utilizing the latex-enhanced immunoturbidimetric method for accurate D-Dimer measurement. It is designed for ease of use in clinical laboratories, providing reliable results for diagnostic and monitoring purposes.

1. High Sensitivity: The kit is capable of detecting low concentrations of D-Dimer, ensuring accurate diagnosis even in early stages of thrombotic disorders.
2. Specificity: The use of mouse anti-human D-D monoclonal antibodies ensures that the assay specifically targets D-Dimer, reducing the risk of cross-reactivity with other proteins.
3. Ease of Use: The kit is designed for straightforward application in clinical laboratories, with clear instructions and minimal preparation required.
4. Stability: The reagents are formulated to maintain stability over a wide range of storage conditions, ensuring consistent performance.
5. Versatility: The kit can be used with a variety of automated analyzers, making it adaptable to different laboratory settings.

The D-Dimer Assay Kit stands out for its high sensitivity, specificity, and ease of use. Its robust design and versatility make it a valuable tool in clinical diagnostics, providing reliable results that are essential for accurate diagnosis and effective patient management.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic disorders. Its high sensitivity and specificity make it an essential tool for clinicians in managing conditions such as deep vein thrombosis and pulmonary embolism.

1. Diagnosis of Deep Vein Thrombosis (DVT): The kit is used to measure D-Dimer levels, which are elevated in patients with DVT, aiding in the diagnosis of this condition.
2. Pulmonary Embolism (PE): Elevated D-Dimer levels are also indicative of PE, and the kit is used to assist in the diagnosis of this potentially life-threatening condition.
3. Disseminated Intravascular Coagulation (DIC): The kit is employed in the diagnosis and monitoring of DIC, a complex condition characterized by widespread clotting and bleeding.
4. Monitoring Anticoagulant Therapy: The kit is used to monitor the effectiveness of anticoagulant therapy, ensuring that patients receive the appropriate treatment.
5. Preoperative Screening: The kit is used in preoperative screening to assess the risk of thrombotic events, helping to ensure patient safety during surgery.

The D-Dimer Assay Kit is a versatile and essential tool in clinical practice. Its applications range from diagnosing thrombotic disorders to monitoring treatment efficacy, making it a critical component in patient care. The kit's reliability and accuracy ensure that clinicians can make informed decisions, ultimately improving patient outcomes.

Purchasing Guide

The D-Dimer Assay Kit is available for purchase through various medical suppliers. When purchasing, it is important to consider factors such as product specifications, intended use, and budget to ensure that the kit meets the specific needs of your laboratory.

1. Product Specifications: Ensure that the kit meets the required specifications for sensitivity, specificity, and stability. Verify that it is compatible with your laboratory's equipment.
2. Product Type: Choose the appropriate type of kit based on your laboratory's needs. Consider whether you require a manual or automated assay, and whether the kit is suitable for high-throughput testing.
3. Budget: Determine your budget for the kit, taking into account the cost per test and the overall value provided by the kit. Consider any additional costs, such as shipping and handling.
4. Usage Scenarios: Assess the intended use of the kit in your laboratory. Consider the volume of testing required, the types of samples to be analyzed, and the specific clinical applications for which the kit will be used.

Purchasing the D-Dimer Assay Kit requires careful consideration of various factors, including product specifications, type, budget, and intended use. By taking these factors into account, you can ensure that the kit you choose will meet the specific needs of your laboratory, providing reliable and accurate results for your clinical applications.

 Precautions

When using the D-Dimer Assay Kit, it is important to follow all safety and handling precautions to ensure accurate results and prevent contamination. Proper storage, handling, and disposal of reagents are essential for maintaining the integrity of the assay.

1. Storage Conditions: Store the kit at the recommended temperature to maintain the stability and effectiveness of the reagents. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling: Use appropriate personal protective equipment (PPE) when handling the reagents. Avoid contact with skin and eyes, and do not ingest the reagents.
3. Contamination Prevention: Ensure that all equipment and surfaces are clean and free from contaminants. Use sterile techniques when handling samples and reagents.
4. Disposal: Dispose of used reagents and samples according to local regulations and guidelines. Do not dispose of hazardous materials in regular waste streams.
5. Calibration and Quality Control: Regularly calibrate the assay and perform quality control checks to ensure accurate and reliable results. Follow the manufacturer's instructions for calibration and quality control procedures.

The D-Dimer Assay Kit requires careful handling and adherence to safety precautions to ensure accurate and reliable results. Proper storage, handling, and disposal of reagents are essential, as is regular calibration and quality control. By following these precautions, you can maintain the integrity of the assay and ensure the safety of laboratory personnel.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list