Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Detection Kit (Fluorescence Immunoassay)
The D-Dimer Detection Kit is composed of a test card, which includes a sample pad, nitrocellulose membrane, conjugate pad, absorbent paper, and PVC backing. The nitrocellulose membrane is coated with D-Dimer monoclonal antibodies (0.1-2mg/mL) and anti-chicken IgY polyclonal antibodies (0.1-2mg/mL). The conjugate pad is coated with D-Dimer monoclonal antibodies (0.1-2mg/mL) and chicken IgY (0.1-2mg/mL). The sample pad is made of glass fiber membrane. The detection buffer consists of 0.01M phosphate buffer and Proclin 300 (0.3g/L).
Product English Name:
D-Dimer Detection Kit (Fluorescence Immunoassay)
Alias:
D-Dimer Test Kit,Fluorescent D-Dimer Assay
Intended Use:
This kit is designed for the quantitative detection of D-Dimer levels in plasma or whole blood samples using a fluorescence immunoassay sandwich method. It is widely used in clinical settings to assess coagulation disorders, deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
Product Introduction

The D-Dimer Detection Kit (Fluorescence Immunoassay) is a state-of-the-art diagnostic tool designed for the accurate and rapid quantification of D-Dimer levels in blood samples. Utilizing advanced fluorescence immunoassay technology, this kit offers high sensitivity and specificity, making it an essential tool in the diagnosis and monitoring of thrombotic conditions. Its robust design ensures reliable performance in various clinical environments.

1. The kit features a highly sensitive fluorescence immunoassay method, ensuring precise detection of D-Dimer levels even at low concentrations. This makes it particularly useful in early diagnosis and monitoring of thrombotic events.
2. The test card is composed of multiple layers, including a sample pad, nitrocellulose membrane, conjugate pad, absorbent paper, and PVC backing. Each layer is meticulously designed to ensure optimal performance and accuracy during the testing process.
3. The primary use of this kit is in clinical laboratories and hospitals for the diagnosis and management of conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation. It is also used in research settings to study coagulation disorders.

The D-Dimer Detection Kit, also known as the Fluorescent D-Dimer Assay, is a critical tool in modern medicine. Its ability to accurately measure D-Dimer levels in blood samples makes it indispensable in diagnosing and managing thrombotic conditions. The kit's sophisticated design and reliable performance ensure that it meets the high standards required in clinical and research settings.

Main Features

The D-Dimer Detection Kit offers high sensitivity and specificity in detecting D-Dimer levels, making it a reliable tool for diagnosing thrombotic conditions. Its user-friendly design ensures ease of use in clinical settings.

1. High Sensitivity: The kit can detect D-Dimer levels at very low concentrations, making it ideal for early diagnosis of thrombotic events.
2. Specificity: The use of monoclonal antibodies ensures that the kit specifically targets D-Dimer, reducing the risk of false positives.
3. Rapid Results: The fluorescence immunoassay method provides quick and accurate results, essential for timely clinical decision-making.
4. User-Friendly: The kit is designed for ease of use, with clear instructions and minimal preparation required.
5. Robust Design: The test card and buffer components are designed to withstand various storage and handling conditions, ensuring consistent performance.

The D-Dimer Detection Kit stands out for its high sensitivity, specificity, and user-friendly design. These features make it an invaluable tool in clinical settings, where accurate and rapid diagnosis of thrombotic conditions is crucial. Its robust design ensures reliable performance, even in challenging environments.

Clinical Applications

The D-Dimer Detection Kit is widely used in clinical settings for the diagnosis and management of thrombotic conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.

1. Diagnosis of Deep Vein Thrombosis (DVT): The kit is used to detect elevated D-Dimer levels, which are indicative of DVT.
2. Pulmonary Embolism (PE): Elevated D-Dimer levels are also associated with PE, and the kit is used to aid in its diagnosis.
3. Disseminated Intravascular Coagulation (DIC): The kit helps in the diagnosis and monitoring of DIC, a condition characterized by widespread clotting and bleeding.
4. Post-Surgical Monitoring: The kit is used to monitor patients post-surgery to detect any thrombotic complications.
5. Research Applications: The kit is also used in research settings to study coagulation disorders and the efficacy of anticoagulant therapies.

The D-Dimer Detection Kit is a versatile tool in clinical practice, used for diagnosing and managing a range of thrombotic conditions. Its ability to provide rapid and accurate results makes it essential in emergency and routine clinical settings. Additionally, its use in research further underscores its importance in advancing our understanding of coagulation disorders.

Purchasing Guide

When purchasing the D-Dimer Detection Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical or research needs.

1. Product Specifications: Ensure the kit meets the required sensitivity and specificity for your intended use. Check the storage conditions and shelf life.
2. Product Types: There may be different versions of the kit available, such as those designed for specific sample types (plasma vs. whole blood). Choose the one that best fits your needs.
3. Budget: Consider the cost of the kit, including any additional reagents or equipment required for its use. Ensure it fits within your budget without compromising on quality.
4. Intended Use: Determine whether the kit will be used in a clinical or research setting. Ensure it is approved for use in your region and meets any regulatory requirements.

Purchasing the D-Dimer Detection Kit requires careful consideration of various factors, including product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that the kit you choose will meet your clinical or research needs effectively and efficiently.

 Precautions

Proper handling and storage of the D-Dimer Detection Kit are essential to ensure accurate results and prolong its shelf life. Follow all instructions carefully to avoid contamination or degradation of the components.

1. Storage Conditions: Store the kit at the recommended temperature to prevent degradation of the reagents. Avoid exposure to direct sunlight or extreme temperatures.
2. Handling: Use gloves and other protective equipment when handling the kit to prevent contamination. Ensure all components are used before their expiration date.
3. Sample Preparation: Follow the instructions for sample preparation carefully to ensure accurate results. Avoid hemolysis or contamination of the blood samples.
4. Calibration: Regularly calibrate the equipment used with the kit to ensure consistent and accurate results.
5. Disposal: Dispose of used components according to local regulations to prevent environmental contamination.

The D-Dimer Detection Kit requires careful handling and storage to ensure its effectiveness and longevity. By following the recommended precautions, you can avoid contamination, ensure accurate results, and comply with regulatory requirements. Proper disposal of used components is also essential to protect the environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files