Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
1,5-Anhydroglucitol (1,5-AG) Assay Kit (Enzymatic Method)
The 1,5-Anhydroglucitol (1,5-AG) Assay Kit is composed of two main reagents: R1 and R2. R1 contains p-hydroxybenzoate (25 mmol/L), glucose oxidase (≥0.6 KU/ml), phosphate buffer (100 mmol/L), 4-aminoantipyrine (0.5 mmol/L), and peroxidase (≥2.0 KU/L). R2 consists of phosphate buffer (0.1 mol/L), pyranose oxidase (≥1.5 KU/L), and a stabilizer (0.02%). These components work together to facilitate the enzymatic measurement of 1,5-AG levels in human serum.
Product English Name:
1,5-Anhydroglucitol (1,5-AG) Assay Kit (Enzymatic Method)
Alias:
1,5-AG Test Kit,Glycomark Assay Kit
Intended Use:
This kit is designed for the in vitro quantitative determination of 1,5-anhydroglucitol (1,5-AG) levels in human serum. It is commonly used in clinical settings to monitor short-term glycemic control, particularly in patients with diabetes, as 1,5-AG levels are inversely related to blood glucose levels.
Product Introduction

The 1,5-Anhydroglucitol (1,5-AG) Assay Kit is a specialized diagnostic tool used to measure the concentration of 1,5-AG in human serum. This kit employs an enzymatic method, ensuring high accuracy and reliability. It is particularly useful in diabetes management, as 1,5-AG levels provide insights into short-term glycemic control, complementing traditional markers like HbA1c.

1. The kit features a highly sensitive enzymatic reaction that ensures precise measurement of 1,5-AG levels. The inclusion of glucose oxidase and pyranose oxidase allows for specific detection of 1,5-AG without interference from other serum components.
2. The composition of the kit includes two reagents, R1 and R2, which are optimized for stability and performance. R1 contains a combination of enzymes and buffers that initiate the reaction, while R2 provides the necessary environment for the enzymatic process to occur efficiently.
3. The primary use of this kit is in clinical laboratories for monitoring glycemic control in diabetic patients. It is particularly valuable for assessing short-term glucose fluctuations, which are not captured by long-term markers like HbA1c.

The 1,5-Anhydroglucitol (1,5-AG) Assay Kit, also known as the Glycomark Assay Kit, is a reliable tool for measuring 1,5-AG levels in serum. Its enzymatic method ensures accuracy, making it a valuable asset in diabetes management. The kit's design and composition are tailored for clinical use, providing insights into short-term glycemic control.

Main Features

The 1,5-AG Assay Kit offers high sensitivity and specificity in measuring 1,5-AG levels. Its enzymatic method ensures reliable results, making it a preferred choice for clinical diagnostics.

1. The kit utilizes a dual-enzyme system (glucose oxidase and pyranose oxidase) to specifically detect 1,5-AG, minimizing cross-reactivity with other serum components.
2. It provides a wide dynamic range, allowing for accurate measurement of 1,5-AG levels across a broad spectrum of concentrations.
3. The reagents are stable and easy to handle, ensuring consistent performance over time.
4. The kit is compatible with automated analyzers, making it suitable for high-throughput clinical laboratories.
5. It includes a detailed protocol and quality control materials, ensuring reliable and reproducible results.

The 1,5-AG Assay Kit stands out for its precision and ease of use. Its enzymatic approach, combined with stable reagents and compatibility with automated systems, makes it an essential tool for clinical diagnostics, particularly in diabetes management.

Clinical Applications

The 1,5-AG Assay Kit is widely used in clinical settings to monitor glycemic control in diabetic patients. It provides valuable insights into short-term glucose fluctuations, complementing traditional markers like HbA1c.

1. The kit is used to assess short-term glycemic control, particularly in patients with type 1 and type 2 diabetes.
2. It helps in identifying postprandial glucose excursions, which are not captured by HbA1c measurements.
3. The kit is valuable in research studies focused on understanding the relationship between 1,5-AG levels and glucose metabolism.
4. It is used in clinical trials to evaluate the efficacy of new diabetes treatments.
5. The kit is also employed in routine clinical practice to monitor patients' response to diabetes management strategies.

The 1,5-AG Assay Kit is a versatile tool in clinical practice, offering insights into short-term glycemic control. Its applications range from routine patient monitoring to research and clinical trials, making it an indispensable asset in diabetes care.

Purchasing Guide

When purchasing the 1,5-AG Assay Kit, consider factors such as product specifications, intended use, budget, and compatibility with existing laboratory equipment.

1. Product parameters: Ensure the kit meets your laboratory's requirements for sensitivity, specificity, and dynamic range.
2. Product type: Choose between manual and automated kits based on your laboratory's workflow and throughput needs.
3. Budget: Consider the cost per test and the overall value offered by the kit, including stability and ease of use.
4. Usage scenarios: Evaluate the kit's suitability for your specific clinical or research applications, such as diabetes management or clinical trials.

Purchasing the 1,5-AG Assay Kit requires careful consideration of various factors, including product specifications, budget, and intended use. By selecting the right kit, you can ensure reliable and accurate results in your clinical or research setting.

 Precautions

Proper handling and storage of the 1,5-AG Assay Kit are essential to ensure accurate results. Follow the manufacturer's instructions carefully to avoid errors.

1. Store the kit at the recommended temperature to maintain reagent stability and performance.
2. Avoid contamination of reagents by using clean pipettes and labware.
3. Follow the protocol precisely, including incubation times and reagent volumes, to ensure accurate results.
4. Perform regular quality control checks to verify the kit's performance and reliability.
5. Dispose of used reagents and materials according to local regulations and laboratory safety guidelines.

The 1,5-AG Assay Kit requires careful handling and storage to ensure accurate and reliable results. By following the manufacturer's instructions and adhering to laboratory safety protocols, you can maximize the kit's performance and minimize the risk of errors.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files