The D-Dimer Calibration Control is a high-quality control material specifically designed for the accurate measurement of D-Dimer levels in human serum. It is essential for maintaining the precision and reliability of D-Dimer assays in clinical laboratories. The product includes two levels of D-Dimer concentrations, allowing for comprehensive quality control across a range of clinical scenarios.
1. The D-Dimer Calibration Control is characterized by its high stability and consistency, ensuring reliable results across different batches and platforms. It is formulated to mimic human serum, providing a realistic matrix for accurate D-Dimer measurement.
2. The product is composed of lyophilized human serum containing D-Dimer at two distinct levels. This composition allows for the evaluation of assay performance across a wide range of D-Dimer concentrations, ensuring robust quality control.
3. The primary use of this product is in the quality control of D-Dimer assays, particularly in conjunction with Mindray reagents and chemiluminescence immunoassay analyzers. It helps laboratories maintain the accuracy and reliability of their D-Dimer measurements, which are critical for diagnosing and monitoring thrombotic disorders.
The D-Dimer Calibration Control, also known as D-Dimer QC Material or D-Dimer Control Serum, is an indispensable tool for clinical laboratories. Its carefully formulated composition and dual concentration levels make it a reliable choice for ensuring the accuracy of D-Dimer assays. Whether you're running routine tests or troubleshooting assay performance, this product provides the consistency and reliability you need.
The D-Dimer Calibration Control offers precise and reliable quality control for D-Dimer assays, ensuring accurate measurement across different platforms and batches.
1. The product provides two levels of D-Dimer concentrations, allowing for comprehensive quality control across a range of clinical scenarios.
2. It is formulated with lyophilized human serum, ensuring a realistic matrix for accurate D-Dimer measurement.
3. The control material is highly stable, providing consistent results over time and across different batches.
4. It is compatible with Mindray reagents and chemiluminescence immunoassay analyzers, ensuring seamless integration into existing laboratory workflows.
5. The target value sheet includes detailed information on target values and reference ranges, facilitating easy interpretation of results.
The D-Dimer Calibration Control stands out for its precision, stability, and compatibility. With its dual concentration levels and realistic human serum matrix, it ensures that your D-Dimer assays are accurate and reliable. Whether you're a seasoned lab technician or new to D-Dimer testing, this product offers the consistency and ease of use you need.
The D-Dimer Calibration Control is widely used in clinical laboratories for the quality control of D-Dimer assays, ensuring accurate diagnosis and monitoring of thrombotic disorders.
1. In clinical diagnostics, the product is used to ensure the accuracy of D-Dimer measurements, which are critical for diagnosing deep vein thrombosis (DVT) and pulmonary embolism (PE).
2. It is also used in the monitoring of patients undergoing anticoagulant therapy, providing reliable data to guide treatment decisions.
3. The control material is essential for validating the performance of new D-Dimer assays and reagents, ensuring they meet clinical standards.
4. In research settings, the product is used to study the role of D-Dimer in various thrombotic and inflammatory conditions, providing a reliable reference for experimental data.
5. The product is also used in the training of laboratory personnel, providing a consistent and reliable material for teaching and proficiency testing.
The D-Dimer Calibration Control is a versatile tool in clinical and research settings. Its reliable performance and compatibility with various platforms make it an essential component of D-Dimer testing. Whether you're diagnosing thrombotic disorders, monitoring treatment, or conducting research, this product ensures that your results are accurate and trustworthy.
When purchasing the D-Dimer Calibration Control, consider factors such as product specifications, types, budget, and intended use to ensure you select the right product for your needs.
1. Product specifications: Ensure the product meets your laboratory's requirements for D-Dimer concentration levels, stability, and compatibility with your assay platform.
2. Product types: Choose between different levels of D-Dimer concentrations based on your clinical needs and the range of D-Dimer values you typically encounter.
3. Budget: Consider the cost-effectiveness of the product, including the number of tests it can support and its shelf life.
4. Usage scenarios: Evaluate the product's suitability for your specific clinical or research applications, including its compatibility with your existing laboratory equipment and workflows.
Selecting the right D-Dimer Calibration Control involves careful consideration of your laboratory's needs and budget. By focusing on product specifications, types, and usage scenarios, you can ensure that you choose a product that delivers reliable and accurate results, supporting your clinical and research objectives.
Proper handling and storage of the D-Dimer Calibration Control are essential to maintain its stability and ensure accurate results.
1. Store the product at the recommended temperature to preserve its stability and prevent degradation.
2. Handle the lyophilized control material with care, ensuring it is reconstituted according to the manufacturer's instructions to maintain its integrity.
3. Avoid contamination by using sterile techniques when handling the control material and reagents.
4. Regularly calibrate and maintain your assay equipment to ensure accurate and consistent results.
5. Follow all safety protocols when handling human serum-based products, including the use of personal protective equipment (PPE) and proper disposal of biohazardous materials.
The D-Dimer Calibration Control requires careful handling and storage to ensure its reliability. By following the recommended precautions, you can maintain the product's stability and accuracy, ensuring that your D-Dimer assays provide consistent and trustworthy results. Always prioritize safety and proper laboratory practices when working with this product.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.