The 1,5-AG Assay Kit is a state-of-the-art diagnostic tool used to measure 1,5-anhydro-D-glucitol levels in human serum. This kit employs a chemiluminescent enzyme assay method, ensuring high sensitivity and accuracy. It is widely utilized in clinical laboratories for glycemic control monitoring, particularly in diabetic patients.
1. The kit features a highly sensitive chemiluminescent enzyme assay method, ensuring precise and reliable results. It is designed for ease of use in clinical laboratories, with a straightforward protocol that minimizes handling errors.
2. The composition includes R1 and R2 reagents, calibrators, and controls. R1 contains enzymes such as hexokinase and glucose-6-phosphate dehydrogenase, while R2 includes pyranose oxidase. The calibrators and controls are formulated with 1,5-anhydro-D-glucitol and bovine serum albumin to ensure accurate calibration and quality control.
3. The primary use of this kit is to quantitatively determine 1,5-AG levels in human serum, which is crucial for monitoring blood glucose levels. It is particularly valuable in managing diabetes, as 1,5-AG levels reflect short-term glycemic control.
The 1,5-AG Assay Kit, also known as the Glycemic Control Assay Kit, is an essential tool in clinical diagnostics. Its robust design and precise measurement capabilities make it a reliable choice for monitoring blood glucose levels, particularly in diabetic patients. The kit's composition and ease of use further enhance its appeal in clinical settings.
The 1,5-AG Assay Kit offers high sensitivity and accuracy in measuring 1,5-anhydro-D-glucitol levels. It is designed for clinical use, providing reliable results for glycemic control monitoring.
1. The kit utilizes a chemiluminescent enzyme assay method, ensuring high sensitivity and specificity in detecting 1,5-AG levels.
2. It includes R1 and R2 reagents, which contain a blend of enzymes and stabilizers to ensure consistent performance.
3. The calibrators and controls are formulated with 1,5-anhydro-D-glucitol and bovine serum albumin, providing accurate calibration and quality control.
4. The kit is designed for ease of use in clinical laboratories, with a straightforward protocol that minimizes handling errors.
5. It is particularly valuable in managing diabetes, as 1,5-AG levels reflect short-term glycemic control.
The 1,5-AG Assay Kit stands out for its precision and reliability in measuring 1,5-AG levels. Its user-friendly design and robust composition make it an indispensable tool in clinical diagnostics, particularly for monitoring blood glucose levels in diabetic patients.
The 1,5-AG Assay Kit is widely used in clinical settings for monitoring blood glucose levels, particularly in diabetic patients. It provides valuable insights into short-term glycemic control.
1. The kit is used in clinical laboratories to quantitatively determine 1,5-AG levels in human serum, aiding in the management of diabetes.
2. It is particularly useful for monitoring short-term glycemic control, providing insights into blood glucose fluctuations.
3. The kit is employed in research studies to investigate the relationship between 1,5-AG levels and diabetes management.
4. It is also used in routine clinical practice to assess the effectiveness of diabetes treatment regimens.
5. The kit's high sensitivity and accuracy make it a reliable tool for clinical diagnostics, ensuring precise measurement of 1,5-AG levels.
The 1,5-AG Assay Kit is a versatile tool in clinical diagnostics, particularly for monitoring blood glucose levels in diabetic patients. Its precision and reliability make it an essential component of diabetes management, providing valuable insights into short-term glycemic control.
The 1,5-AG Assay Kit is designed for clinical use, with a focus on ease of use and reliability. This guide provides essential information for purchasing the kit, including product parameters, types, budget considerations, and usage scenarios.
1. Product parameters: The kit includes R1 and R2 reagents, calibrators, and controls. It utilizes a chemiluminescent enzyme assay method for high sensitivity and accuracy.
2. Product types: The kit is available in various configurations to meet different clinical laboratory needs, including different batch sizes and packaging options.
3. Budget considerations: The cost of the kit varies depending on the configuration and batch size. It is important to consider the long-term cost-effectiveness when purchasing.
4. Usage scenarios: The kit is suitable for use in clinical laboratories, research institutions, and hospitals. It is particularly valuable for monitoring blood glucose levels in diabetic patients.
The 1,5-AG Assay Kit is a reliable and cost-effective solution for clinical laboratories. Its versatile design and high performance make it an excellent choice for monitoring blood glucose levels, particularly in diabetic patients. When purchasing, consider the product parameters, types, and budget to ensure the best fit for your needs.
The 1,5-AG Assay Kit requires careful handling and storage to ensure accurate results. This section outlines key precautions to follow when using the kit.
1. Store the kit at the recommended temperature to maintain the stability of the reagents and ensure accurate results.
2. Follow the protocol precisely to avoid handling errors that could affect the accuracy of the assay.
3. Use the calibrators and controls provided with the kit to ensure proper calibration and quality control.
4. Dispose of used reagents and materials according to local regulations to ensure safety and environmental compliance.
5. Regularly check the expiration dates of the reagents and replace them as needed to maintain the kit's performance.
Proper handling and storage of the 1,5-AG Assay Kit are essential for obtaining accurate results. By following the recommended precautions, you can ensure the kit's reliability and performance, making it a valuable tool in clinical diagnostics.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.