Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Quality Control Material
The D-Dimer Quality Control Material is composed of lyophilized porcine plasma anticoagulated with 109mmol/L sodium citrate, 20mg/mL bovine serum albumin, and 20mg/mL sodium benzoate. It is designed to provide target concentration ranges for three levels: Level I (0.2-0.5 µg/mL), Level II (1.5-2.5 µg/mL), and Level III (2.8-3.8 µg/mL). The specific control ranges are batch-dependent and detailed in the target value sheet.
Product English Name:
D-Dimer Quality Control Material
Alias:
D-Dimer QC Material,D-Dimer Control
Intended Use:
This product is intended for use with the company's reagent kits for internal quality control of D-Dimer assays. It ensures the accuracy and reliability of D-Dimer measurements in clinical laboratories.
Product Introduction

The D-Dimer Quality Control Material is a critical component in ensuring the precision and accuracy of D-Dimer assays in clinical laboratories. It is formulated to mimic human plasma and provides a stable and reliable reference for quality control purposes. The material is available in three levels, each designed to cover a specific range of D-Dimer concentrations, making it suitable for various clinical settings.

1. The D-Dimer Quality Control Material is characterized by its stability and consistency, ensuring reliable performance over time. It is designed to mimic human plasma, providing a realistic reference for quality control.
2. The composition includes lyophilized porcine plasma, bovine serum albumin, and sodium benzoate, which together create a stable matrix that closely resembles human plasma. This ensures accurate and reproducible results in D-Dimer assays.
3. The primary use of this material is for internal quality control in clinical laboratories. It is used in conjunction with the company's reagent kits to ensure the accuracy and reliability of D-Dimer measurements, which are crucial for diagnosing and monitoring thrombotic disorders.

The D-Dimer Quality Control Material, also known as D-Dimer QC Material or D-Dimer Control, is an essential tool for clinical laboratories. Its stable composition and precise target concentration ranges make it an invaluable resource for ensuring the accuracy of D-Dimer assays. Whether you're a seasoned lab technician or new to the field, this product offers the reliability and consistency needed for effective quality control.

Main Features

The D-Dimer Quality Control Material offers several key features, including stability, consistency, and precise target concentration ranges, making it an essential tool for quality control in clinical laboratories.

1. Stability: The lyophilized formulation ensures long-term stability, allowing for reliable performance over extended periods.
2. Consistency: The material is designed to provide consistent results, ensuring that each batch performs similarly under the same conditions.
3. Precise Target Ranges: With three levels of target concentrations, the material covers a wide range of D-Dimer levels, making it suitable for various clinical applications.
4. Realistic Matrix: The composition closely mimics human plasma, providing a realistic reference for quality control.
5. Ease of Use: The material is easy to reconstitute and use, making it a convenient choice for laboratory technicians.

The D-Dimer Quality Control Material stands out for its stability, consistency, and precise target ranges. These features make it an indispensable tool for clinical laboratories, ensuring that D-Dimer assays are accurate and reliable. Whether you're managing a high-throughput lab or a smaller facility, this product offers the performance and reliability you need.

Clinical Applications

The D-Dimer Quality Control Material is widely used in clinical laboratories for internal quality control of D-Dimer assays, ensuring accurate and reliable results in the diagnosis and monitoring of thrombotic disorders.

1. Diagnosis of Thrombotic Disorders: The material is used to ensure the accuracy of D-Dimer assays, which are crucial for diagnosing conditions such as deep vein thrombosis and pulmonary embolism.
2. Monitoring Treatment: Accurate D-Dimer measurements are essential for monitoring the effectiveness of anticoagulant therapy in patients with thrombotic disorders.
3. Quality Assurance: The material is used in routine quality control procedures to ensure that laboratory equipment and reagents are functioning correctly.
4. Research Applications: The material is also used in research settings to validate new D-Dimer assays and methodologies.
5. Regulatory Compliance: The use of quality control materials is often required to meet regulatory standards and ensure the reliability of laboratory results.

The D-Dimer Quality Control Material plays a vital role in clinical laboratories, ensuring the accuracy and reliability of D-Dimer assays. Its applications range from diagnosing thrombotic disorders to monitoring treatment and ensuring regulatory compliance. This product is a cornerstone of quality assurance in clinical diagnostics.

Purchasing Guide

When purchasing the D-Dimer Quality Control Material, it is important to consider product specifications, types, budget, and intended use to ensure that the material meets your laboratory's needs.

1. Product Specifications: Review the target concentration ranges and batch-specific control ranges to ensure the material meets your laboratory's requirements.
2. Product Types: Choose from the available levels (I, II, III) based on the D-Dimer concentration ranges you need to cover in your assays.
3. Budget Considerations: Evaluate the cost of the material in relation to your laboratory's budget and the volume of testing you perform.
4. Intended Use: Consider the specific applications for which you will use the material, such as routine quality control, research, or regulatory compliance.

Purchasing the D-Dimer Quality Control Material requires careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that the material meets your laboratory's needs and provides the reliability and accuracy required for effective quality control.

 Precautions

When using the D-Dimer Quality Control Material, it is important to follow proper handling and storage procedures to ensure the material's stability and performance.

1. Storage: Store the material at the recommended temperature to maintain its stability and prevent degradation.
2. Handling: Follow proper handling procedures to avoid contamination and ensure accurate results.
3. Reconstitution: Use the correct volume of diluent and follow the recommended reconstitution procedure to ensure the material performs as expected.
4. Usage: Use the material within the specified shelf life and follow the recommended testing procedures to ensure accurate and reliable results.
5. Disposal: Dispose of used material according to local regulations and laboratory protocols to ensure safety and compliance.

Proper handling, storage, and usage of the D-Dimer Quality Control Material are essential to ensure its stability and performance. By following the recommended procedures, you can maintain the material's integrity and ensure accurate and reliable results in your D-Dimer assays. Always prioritize safety and compliance when using and disposing of the material.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files