Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Assay Kit (Quantum Dot Fluorescence Immunochromatography)
The kit primarily consists of a detection card, sample diluent, IC card, and user manual. The detection card includes a test strip, plastic clip, and QR code. The test strip contains key components such as goat anti-chicken IgY (fixed on the 'Control Line (C)' of the nitrocellulose membrane), D-Dimer antibody (fixed on the 'Test Line (T)' of the nitrocellulose membrane), quantum dot fluorescent-labeled D-Dimer antibody, and quantum dot fluorescent-labeled chicken IgY (fixed on the glass fiber membrane). The test strip is secured within the plastic clip, which features a QR code containing product details like the English abbreviation, batch number, and expiration date. The detection card is sealed in an aluminum foil bag. The sample diluent is provided in 100µL tubes, primarily composed of sodium chloride. The IC card contains the calibration curve for the specific batch. Note: Components from different batches are not interchangeable.
Product English Name:
D-Dimer Assay Kit (Quantum Dot Fluorescence Immunochromatography)
Alias:
D-Dimer Test Kit,Fluorescent D-Dimer Assay
Intended Use:
This kit is designed for the in vitro quantitative determination of D-Dimer concentration in human plasma and whole blood. It is widely used in clinical settings to assess coagulation disorders, monitor thrombotic conditions, and evaluate the risk of deep vein thrombosis (DVT) or pulmonary embolism (PE).
Product Introduction

The D-Dimer Assay Kit (Quantum Dot Fluorescence Immunochromatography) is a cutting-edge diagnostic tool designed for accurate and rapid quantification of D-Dimer levels in human blood samples. Utilizing advanced quantum dot fluorescence technology, this kit offers high sensitivity and specificity, making it an essential tool for clinicians in diagnosing and monitoring thrombotic conditions. Its user-friendly design ensures ease of use, while the inclusion of an IC card for calibration ensures reliable and consistent results across different batches.

1. The kit features a highly sensitive quantum dot fluorescence detection system, which enhances the accuracy of D-Dimer measurement. This technology allows for the detection of even low concentrations of D-Dimer, making it particularly useful in early diagnosis and monitoring of thrombotic disorders.
2. The test strip is composed of multiple layers, including a nitrocellulose membrane with immobilized antibodies for control and test lines, and a glass fiber membrane with quantum dot fluorescent-labeled antibodies. This multi-layered structure ensures precise and reliable detection of D-Dimer levels.
3. The kit is specifically designed for use in clinical laboratories and hospitals. It aids in the diagnosis of conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation (DIC). The quantitative results provided by the kit help clinicians make informed decisions regarding patient care and treatment.

The D-Dimer Assay Kit is a sophisticated diagnostic tool that combines advanced quantum dot fluorescence technology with a user-friendly design. Its high sensitivity and specificity make it an invaluable resource for clinicians in diagnosing and monitoring thrombotic conditions. The inclusion of an IC card for calibration ensures consistent and reliable results, making it a trusted choice in clinical settings.

Main Features

The D-Dimer Assay Kit offers high sensitivity and specificity in detecting D-Dimer levels, utilizing quantum dot fluorescence technology for accurate results. It is designed for ease of use in clinical settings, with a user-friendly interface and reliable calibration.

1. The kit employs quantum dot fluorescence technology, which provides enhanced sensitivity and specificity in detecting D-Dimer levels, even at low concentrations.
2. The test strip is designed with multiple layers, including a nitrocellulose membrane and a glass fiber membrane, ensuring precise and reliable detection of D-Dimer.
3. The kit includes an IC card that contains the calibration curve for the specific batch, ensuring consistent and accurate results across different batches.
4. The user-friendly design of the kit allows for easy operation, making it suitable for use in various clinical settings, including hospitals and laboratories.
5. The kit is specifically designed for the quantitative determination of D-Dimer levels in human plasma and whole blood, aiding in the diagnosis and monitoring of thrombotic conditions.

The D-Dimer Assay Kit stands out for its advanced quantum dot fluorescence technology, which ensures high sensitivity and specificity in detecting D-Dimer levels. Its user-friendly design and reliable calibration make it an essential tool for clinicians in diagnosing and monitoring thrombotic conditions.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic conditions, such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.

1. The kit is used in the diagnosis of deep vein thrombosis (DVT), providing quantitative results that help clinicians assess the risk and severity of the condition.
2. It is also employed in the diagnosis of pulmonary embolism (PE), where accurate D-Dimer levels are crucial for determining the appropriate treatment plan.
3. The kit aids in the monitoring of disseminated intravascular coagulation (DIC), a condition characterized by abnormal blood clotting, by providing precise D-Dimer measurements.
4. In addition to these conditions, the kit is used in the evaluation of other thrombotic disorders, helping clinicians make informed decisions regarding patient care.
5. The kit's high sensitivity and specificity make it a valuable tool in emergency settings, where rapid and accurate diagnosis is critical.

The D-Dimer Assay Kit is a versatile diagnostic tool used in various clinical applications, including the diagnosis and monitoring of thrombotic conditions. Its high sensitivity and specificity make it an invaluable resource for clinicians, particularly in emergency settings where rapid and accurate diagnosis is essential.

Purchasing Guide

When purchasing the D-Dimer Assay Kit, it is important to consider factors such as product specifications, types, budget, and intended use to ensure the best fit for your clinical needs.

1. Product specifications: Ensure that the kit meets the required sensitivity and specificity for your clinical applications. Check the batch number and expiration date to ensure the product's reliability.
2. Product types: Consider the different types of kits available, such as those designed for specific clinical settings or those with additional features like integrated calibration curves.
3. Budget: Evaluate the cost of the kit in relation to its features and the volume of tests you plan to perform. Consider the long-term cost-effectiveness of the product.
4. Intended use: Determine the specific clinical applications for which you will use the kit, such as diagnosing DVT, PE, or DIC, and ensure that the kit is suitable for these purposes.

Purchasing the D-Dimer Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can ensure that the kit meets your clinical needs and provides reliable and accurate results.

 Precautions

When using the D-Dimer Assay Kit, it is important to follow all safety precautions to ensure accurate results and prevent contamination or injury.

1. Always wear appropriate personal protective equipment (PPE), such as gloves and lab coats, when handling blood samples and kit components.
2. Ensure that all components of the kit are stored and handled according to the manufacturer's instructions to maintain their integrity and performance.
3. Avoid cross-contamination by using separate pipettes and tips for each sample and kit component. Dispose of used materials in biohazard waste containers.
4. Follow the calibration and quality control procedures outlined in the user manual to ensure the accuracy and reliability of the results.
5. In case of accidental exposure to blood or kit components, follow the appropriate first aid procedures and seek medical attention if necessary.

Using the D-Dimer Assay Kit requires strict adherence to safety precautions to ensure accurate results and prevent contamination or injury. By following the manufacturer's instructions and using appropriate PPE, you can safely and effectively use the kit in your clinical practice.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files