Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Assay Kit (Fluorescence Immunochromatography)
The D-Dimer Assay Kit is composed of two main components: (1) Test Cards, which include single-use test strips made of a plastic card and a nitrocellulose membrane. The membrane contains a detection zone coated with D-Dimer monoclonal antibody 1 and a control zone coated with goat anti-mouse IgG. The test strip also includes a fluorescent pad with fluorescently labeled D-Dimer monoclonal antibody 2, a sample pad, absorbent paper, and a PVC backing. (2) ID Cards, which are used in conjunction with the instrument to store data related to the kit, such as the project name, lot number, and calibration curve.
Product English Name:
D-Dimer Assay Kit (Fluorescence Immunochromatography)
Alias:
D-Dimer Test Kit,Fluorescent D-Dimer Kit
Intended Use:
This kit is designed for the in vitro quantitative detection of D-Dimer concentration in human plasma and whole blood. It is widely used in clinical settings to assess coagulation disorders, deep vein thrombosis, pulmonary embolism, and other conditions related to abnormal blood clotting.
Product Introduction

The D-Dimer Assay Kit (Fluorescence Immunochromatography) is a cutting-edge diagnostic tool designed for the precise measurement of D-Dimer levels in human blood. Utilizing advanced fluorescence immunochromatography technology, this kit offers high sensitivity and specificity, making it an essential tool in clinical laboratories. It is particularly useful in diagnosing and monitoring conditions associated with abnormal blood clotting, such as deep vein thrombosis and pulmonary embolism.

1. The kit features a highly sensitive fluorescence detection system, ensuring accurate and reliable results. The use of monoclonal antibodies specific to D-Dimer enhances the precision of the assay.
2. The test strip is composed of multiple layers, including a nitrocellulose membrane, a fluorescent pad, a sample pad, absorbent paper, and a PVC backing. Each layer plays a crucial role in the accurate detection of D-Dimer levels.
3. The kit is primarily used for the quantitative detection of D-Dimer in human plasma and whole blood. It is an invaluable tool in the diagnosis and management of coagulation disorders and thrombotic conditions.

The D-Dimer Assay Kit, also known as the Fluorescent D-Dimer Kit, is a sophisticated diagnostic tool that combines advanced technology with precision engineering. Its ability to accurately measure D-Dimer levels makes it indispensable in clinical settings, particularly for diagnosing and monitoring conditions related to abnormal blood clotting.

Main Features

The D-Dimer Assay Kit offers high sensitivity and specificity in detecting D-Dimer levels, making it a reliable tool for diagnosing coagulation disorders and thrombotic conditions.

1. The kit utilizes a fluorescence immunochromatography method, which provides high sensitivity and specificity in detecting D-Dimer levels.
2. The test strips are designed with multiple layers, including a nitrocellulose membrane and a fluorescent pad, ensuring accurate and reliable results.
3. The kit includes ID cards that store essential data, such as the project name, lot number, and calibration curve, facilitating easy integration with laboratory instruments.
4. The kit is designed for single-use, ensuring hygiene and reducing the risk of cross-contamination.
5. The kit is compatible with a wide range of laboratory instruments, making it versatile and easy to integrate into existing workflows.

The D-Dimer Assay Kit stands out for its high sensitivity, specificity, and ease of use. Its advanced fluorescence detection system and well-designed test strips make it a reliable choice for clinical laboratories. The inclusion of ID cards further enhances its utility by simplifying data management and integration with laboratory instruments.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings for the diagnosis and monitoring of coagulation disorders, deep vein thrombosis, pulmonary embolism, and other conditions related to abnormal blood clotting.

1. The kit is used in the diagnosis of deep vein thrombosis (DVT), a condition where blood clots form in the deep veins, typically in the legs.
2. It is also used in the diagnosis of pulmonary embolism (PE), a potentially life-threatening condition where blood clots travel to the lungs.
3. The kit is employed in the monitoring of patients undergoing anticoagulant therapy, ensuring that the treatment is effective and safe.
4. It is used in the assessment of disseminated intravascular coagulation (DIC), a condition characterized by widespread blood clotting and bleeding.
5. The kit is also utilized in the evaluation of other conditions associated with abnormal blood clotting, such as stroke and myocardial infarction.

The D-Dimer Assay Kit is a versatile tool in clinical practice, playing a crucial role in the diagnosis and monitoring of various coagulation disorders and thrombotic conditions. Its ability to provide accurate and reliable results makes it an essential component of modern clinical laboratories.

Purchasing Guide

When purchasing the D-Dimer Assay Kit, it is important to consider factors such as product specifications, types, budget, and intended use to ensure that the kit meets your laboratory's needs.

1. Product Specifications: Ensure that the kit's specifications, such as sensitivity, specificity, and detection range, align with your laboratory's requirements.
2. Product Types: Consider the different types of kits available, such as those designed for specific instruments or those with additional features like ID cards.
3. Budget: Evaluate the cost of the kit in relation to your laboratory's budget, taking into account the potential long-term savings from accurate and reliable results.
4. Intended Use: Determine the specific applications for which the kit will be used, such as diagnosing DVT, PE, or monitoring anticoagulant therapy, to ensure that the kit is suitable for your needs.

Purchasing the D-Dimer Assay Kit requires careful consideration of various factors, including product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that the kit you choose will meet your laboratory's needs and provide accurate and reliable results.

 Precautions

When using the D-Dimer Assay Kit, it is important to follow proper handling and storage procedures to ensure accurate results and maintain the integrity of the kit.

1. Storage: Store the kit at the recommended temperature to maintain the stability of the reagents and ensure accurate results.
2. Handling: Handle the test strips and ID cards with care to avoid contamination and ensure the integrity of the results.
3. Sample Preparation: Follow the recommended procedures for sample collection and preparation to ensure accurate and reliable results.
4. Instrument Calibration: Regularly calibrate the laboratory instruments used with the kit to ensure accurate and consistent results.
5. Disposal: Dispose of used test strips and other materials in accordance with local regulations and laboratory protocols to ensure safety and compliance.

Proper handling, storage, and disposal of the D-Dimer Assay Kit are essential to ensure accurate results and maintain the integrity of the kit. By following the recommended procedures, you can ensure that the kit performs as expected and provides reliable results for your clinical applications.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files