Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Assay Kit (Magnetic Particle Chemiluminescence Method)
The D-Dimer Assay Kit is composed of magnetic particles coated with specific antibodies, chemiluminescent substrates, and calibration standards. It is designed for precise and sensitive detection of D-Dimer levels in human plasma samples, ensuring high accuracy and reliability in clinical diagnostics.
Product English Name:
D-Dimer Assay Kit (Magnetic Particle Chemiluminescence Method)
Alias:
D-Dimer Test Kit,D-Dimer Detection Kit
Intended Use:
This kit is used for the quantitative detection of D-Dimer concentration in human plasma samples. It is essential in diagnosing and monitoring conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
Product Introduction

The D-Dimer Assay Kit (Magnetic Particle Chemiluminescence Method) is a state-of-the-art diagnostic tool designed for the accurate measurement of D-Dimer levels in human plasma. Utilizing advanced magnetic particle technology and chemiluminescent detection, this kit offers high sensitivity and specificity, making it an indispensable tool in clinical laboratories.

1. The kit features a highly sensitive detection system that ensures accurate measurement of D-Dimer levels, even at low concentrations. This is crucial for early diagnosis and monitoring of thrombotic disorders.
2. The composition includes magnetic particles coated with specific antibodies, chemiluminescent substrates, and calibration standards. These components work together to provide a robust and reliable assay system.
3. The primary use of this kit is in the quantitative detection of D-Dimer in human plasma, aiding in the diagnosis and management of conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.

The D-Dimer Assay Kit, also known as the D-Dimer Test Kit, is a vital tool in clinical diagnostics. Its advanced technology and precise detection capabilities make it an essential component in the diagnosis and monitoring of thrombotic disorders. The kit's robust design and reliable performance ensure accurate results, providing clinicians with the information they need to make informed decisions.

Main Features

The D-Dimer Assay Kit offers high sensitivity and specificity in detecting D-Dimer levels, making it a reliable tool for clinical diagnostics. Its advanced magnetic particle technology ensures accurate and consistent results.

1. The kit provides highly sensitive detection of D-Dimer levels, ensuring accurate results even at low concentrations.
2. It utilizes magnetic particle technology, which enhances the precision and reliability of the assay.
3. The chemiluminescent detection system offers a wide dynamic range, allowing for the measurement of a broad spectrum of D-Dimer concentrations.
4. The kit includes calibration standards that ensure consistent and accurate results across different batches.
5. It is designed for ease of use, with a straightforward protocol that minimizes the risk of user error.

The D-Dimer Assay Kit stands out for its high sensitivity, precision, and ease of use. Its advanced technology and reliable performance make it an essential tool for clinicians in diagnosing and monitoring thrombotic disorders. The kit's robust design ensures accurate results, providing confidence in clinical decision-making.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic disorders. Its high sensitivity and specificity make it a valuable tool in managing conditions such as deep vein thrombosis and pulmonary embolism.

1. The kit is used in the diagnosis of deep vein thrombosis (DVT), providing accurate measurement of D-Dimer levels to aid in early detection.
2. It is also employed in the diagnosis of pulmonary embolism (PE), where elevated D-Dimer levels are a key indicator.
3. The kit is used in the management of disseminated intravascular coagulation (DIC), helping to monitor the condition and guide treatment.
4. It is utilized in postoperative monitoring to detect and prevent thrombotic complications.
5. The kit is also used in research settings to study the role of D-Dimer in various thrombotic and inflammatory conditions.

The D-Dimer Assay Kit is a versatile tool in clinical diagnostics, widely used for the diagnosis and monitoring of thrombotic disorders. Its high sensitivity and specificity make it invaluable in managing conditions such as DVT, PE, and DIC. The kit's reliable performance ensures accurate results, aiding clinicians in making informed decisions.

Purchasing Guide

When purchasing the D-Dimer Assay Kit, it is important to consider factors such as product specifications, types, budget, and intended use. This guide provides essential information to help you make an informed decision.

1. Product specifications: Ensure the kit meets your laboratory's requirements for sensitivity, specificity, and dynamic range.
2. Product types: Choose between different formats and sizes based on your laboratory's volume and workflow.
3. Budget: Consider the cost per test and the overall budget for your laboratory's diagnostic needs.
4. Usage scenarios: Evaluate the kit's suitability for your specific clinical applications, such as DVT, PE, or DIC diagnosis.

Purchasing the D-Dimer Assay Kit requires careful consideration of product specifications, types, budget, and intended use. This guide aims to provide you with the necessary information to make an informed decision, ensuring that the kit meets your laboratory's needs and delivers reliable results.

 Precautions

Proper handling and storage of the D-Dimer Assay Kit are essential to ensure accurate results. This section outlines key precautions to follow when using the kit.

1. Always follow the manufacturer's instructions for storage and handling to maintain the kit's integrity.
2. Ensure that all reagents are at room temperature before use to avoid variations in assay performance.
3. Use appropriate personal protective equipment (PPE) when handling samples and reagents to prevent contamination.
4. Regularly calibrate the equipment used with the kit to ensure consistent and accurate results.
5. Dispose of used reagents and samples according to local regulations to maintain a safe laboratory environment.

The D-Dimer Assay Kit requires careful handling and storage to ensure accurate and reliable results. Following the manufacturer's instructions, using appropriate PPE, and maintaining proper laboratory practices are essential to avoid contamination and ensure the kit's performance. Regular calibration and proper disposal of materials are also crucial for maintaining a safe and efficient laboratory environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files