D-Dimer Assay Kit (Chemiluminescence Method)
The D-Dimer Assay Kit is composed of several key components, including Reaction Reagent R1, which contains a D-Dimer mouse monoclonal antibody conjugated with biotin-streptavidin magnetic beads, and Reaction Reagent R2, which includes an acridinium ester-labeled D-Dimer mouse monoclonal antibody. The kit also includes two calibrators, S1 and S2, which are lyophilized products containing D-Dimer natural antigen in a Tris-HCl buffer system with a pH range of 6.8 to 7.8.
Product English Name:
D-Dimer Assay Kit (Chemiluminescence Method)
Alias:
D-Dimer Test Kit,D-Dimer Detection Kit
Intended Use:
This kit is designed for the quantitative determination of D-Dimer levels in human plasma and/or whole blood. It is primarily used in clinical settings to assist in the diagnosis of disseminated intravascular coagulation (DIC) and to monitor thrombolytic therapy. However, it is not intended for the diagnosis or exclusion of venous thromboembolic diseases.
Product Introduction

The D-Dimer Assay Kit (Chemiluminescence Method) is a sophisticated diagnostic tool used to measure D-Dimer levels in human blood. D-Dimer is a fibrin degradation product that is often elevated in conditions associated with thrombosis and fibrinolysis. This kit employs a chemiluminescent immunoassay (CLIA) technique, which offers high sensitivity and specificity, making it a reliable choice for clinical diagnostics.

1. The kit features a highly sensitive chemiluminescent detection system, which ensures accurate and reproducible results. The use of monoclonal antibodies specific to D-Dimer enhances the specificity of the assay.
2. The kit's components are carefully formulated to ensure stability and performance. The reaction reagents are designed to work in tandem, with R1 containing biotin-streptavidin magnetic beads and R2 containing acridinium ester-labeled antibodies, facilitating a robust and efficient assay.
3. The primary application of this kit is in the clinical diagnosis of DIC and the monitoring of thrombolytic therapy. It provides clinicians with critical information to guide treatment decisions, although it is not suitable for diagnosing venous thromboembolic diseases.

The D-Dimer Assay Kit is a vital tool in the clinical laboratory, offering precise and reliable measurements of D-Dimer levels. Its design and components are tailored to meet the demands of modern diagnostics, providing clinicians with the data they need to make informed decisions in the management of thrombotic and fibrinolytic disorders.

Main Features

The D-Dimer Assay Kit offers high sensitivity and specificity in detecting D-Dimer levels, making it an essential tool for clinical diagnostics.

1. The kit utilizes a chemiluminescent immunoassay (CLIA) technique, which provides high sensitivity and specificity in detecting D-Dimer levels.
2. The inclusion of monoclonal antibodies specific to D-Dimer ensures that the assay is highly specific, reducing the likelihood of cross-reactivity with other substances.
3. The kit's reaction reagents are designed to work together efficiently, with R1 containing biotin-streptavidin magnetic beads and R2 containing acridinium ester-labeled antibodies, ensuring a robust and reliable assay.
4. The kit includes two calibrators, S1 and S2, which are essential for standardizing the assay and ensuring accurate quantification of D-Dimer levels.
5. The kit is designed for use in clinical laboratories, providing clinicians with critical information for the diagnosis and monitoring of thrombotic and fibrinolytic disorders.

The D-Dimer Assay Kit is a comprehensive diagnostic tool that combines advanced technology with meticulous design. Its features ensure that it delivers accurate and reliable results, making it an indispensable resource for clinicians managing complex thrombotic conditions.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic and fibrinolytic disorders.

1. The kit is primarily used in the diagnosis of disseminated intravascular coagulation (DIC), a condition characterized by widespread thrombosis and bleeding.
2. It is also employed in the monitoring of thrombolytic therapy, providing clinicians with critical information on the effectiveness of treatment.
3. The kit is used in emergency settings to quickly assess D-Dimer levels, aiding in the rapid diagnosis of acute thrombotic events.
4. In research settings, the kit is used to study the mechanisms of thrombosis and fibrinolysis, contributing to the development of new therapeutic strategies.
5. The kit is also used in routine clinical practice to monitor patients with a history of thrombotic disorders, ensuring timely intervention when necessary.

The D-Dimer Assay Kit plays a crucial role in the clinical management of thrombotic and fibrinolytic disorders. Its applications span from emergency diagnostics to routine monitoring, making it a versatile and essential tool in modern medicine.

Purchasing Guide

The D-Dimer Assay Kit is designed for use in clinical laboratories, and its procurement should be guided by specific considerations to ensure optimal performance.

1. When purchasing the kit, it is important to consider the product parameters, such as sensitivity, specificity, and the range of detection, to ensure it meets the laboratory's needs.
2. The type of kit, whether it is for research or clinical use, should also be considered, as different kits may have varying levels of validation and regulatory compliance.
3. Budget considerations are crucial, as the cost of the kit and its components can vary significantly. It is important to balance cost with the need for high-quality, reliable results.
4. The intended use scenario, such as emergency diagnostics or routine monitoring, should guide the selection of the kit, ensuring that it is suitable for the specific clinical setting.

Procuring the D-Dimer Assay Kit requires careful consideration of various factors, including product specifications, intended use, and budget. By taking these factors into account, laboratories can ensure they select a kit that meets their needs and delivers reliable results.

 Precautions

Proper handling and usage of the D-Dimer Assay Kit are essential to ensure accurate results and maintain safety in the laboratory.

1. Always follow the manufacturer's instructions for storage and handling of the kit components to maintain their stability and performance.
2. Ensure that all laboratory personnel are trained in the proper use of the kit and are aware of the potential hazards associated with its components.
3. Use appropriate personal protective equipment (PPE) when handling the kit, including gloves, lab coats, and safety goggles, to minimize the risk of exposure to hazardous materials.
4. Regularly calibrate and maintain the equipment used with the kit, such as pipettes and microplate readers, to ensure accurate and reproducible results.
5. Dispose of all waste materials in accordance with local regulations and laboratory protocols to prevent contamination and ensure environmental safety.

The D-Dimer Assay Kit is a powerful diagnostic tool, but its effectiveness depends on proper handling and usage. By adhering to safety protocols and following best practices, laboratory personnel can ensure accurate results and maintain a safe working environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files