Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Assay Kit (Immunoturbidimetric Method)
The kit consists of latex reagent, reaction buffer, and an instruction manual. The latex reagent is composed of latex particles (0.1%) labeled with mouse anti-human D-Dimer monoclonal antibody (1μg/ml). The reaction buffer primarily contains 5mmol/L Hepes buffer.
Product English Name:
D-Dimer Assay Kit (Immunoturbidimetric Method)
Alias:
D-Dimer Test Kit,Fibrin Degradation Product Assay Kit
Intended Use:
This kit is intended for the in vitro quantitative determination of D-Dimer levels in human plasma. It is widely used in clinical settings to assess fibrin degradation products, which are crucial for diagnosing conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
Product Introduction

The D-Dimer Assay Kit (Immunoturbidimetric Method) is a highly sensitive and specific diagnostic tool designed for the quantitative measurement of D-Dimer in human plasma. This kit is essential for clinicians to evaluate fibrinolytic activity and diagnose thrombotic disorders. Its robust design ensures reliable and reproducible results, making it a staple in clinical laboratories.

1. The kit features a high-sensitivity latex reagent that ensures accurate detection of D-Dimer levels, even at low concentrations. This makes it particularly useful in early diagnosis and monitoring of thrombotic events.
2. The composition includes latex particles coated with monoclonal antibodies specific to D-Dimer, ensuring high specificity. The reaction buffer, composed of Hepes, provides a stable environment for the immunoassay, enhancing the reliability of the results.
3. The primary use of this kit is in the diagnosis and monitoring of thrombotic disorders. It is also employed in research settings to study fibrinolytic pathways and the role of D-Dimer in various pathological conditions.

The D-Dimer Assay Kit is a vital tool in modern medicine, offering precise and reliable measurements of D-Dimer levels. Its high sensitivity and specificity make it indispensable for diagnosing thrombotic disorders. Whether in a clinical or research setting, this kit provides valuable insights into fibrinolytic activity, helping clinicians make informed decisions.

Main Features

The D-Dimer Assay Kit offers high sensitivity, specificity, and reliability in measuring D-Dimer levels. It is designed for ease of use in clinical laboratories, providing consistent and accurate results.

1. High Sensitivity: The kit can detect low concentrations of D-Dimer, making it suitable for early diagnosis of thrombotic events.
2. Specificity: The use of monoclonal antibodies ensures that the assay is highly specific to D-Dimer, reducing the risk of cross-reactivity.
3. Stability: The reaction buffer maintains a stable pH, ensuring consistent performance across different batches and conditions.
4. Ease of Use: The kit is designed for straightforward operation, requiring minimal training for laboratory personnel.
5. Reproducibility: The assay provides consistent results, which is crucial for clinical decision-making and research applications.

The D-Dimer Assay Kit stands out for its high sensitivity, specificity, and ease of use. Its robust design ensures reliable and reproducible results, making it a trusted tool in clinical laboratories. Whether for diagnosing thrombotic disorders or conducting research, this kit delivers consistent performance.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic disorders. It is also employed in research to study fibrinolytic pathways.

1. Diagnosis of Deep Vein Thrombosis (DVT): The kit is used to measure D-Dimer levels, which are elevated in patients with DVT.
2. Pulmonary Embolism (PE): Elevated D-Dimer levels are indicative of PE, and the kit is used to confirm the diagnosis.
3. Disseminated Intravascular Coagulation (DIC): The kit helps in diagnosing DIC by measuring D-Dimer levels, which are significantly elevated in this condition.
4. Monitoring Anticoagulant Therapy: The kit is used to monitor the effectiveness of anticoagulant therapy in patients with thrombotic disorders.
5. Research Applications: The kit is used in research to study the role of D-Dimer in various pathological conditions and to explore new therapeutic approaches.

The D-Dimer Assay Kit is a versatile tool in both clinical and research settings. Its ability to accurately measure D-Dimer levels makes it indispensable for diagnosing and monitoring thrombotic disorders. In research, it provides valuable insights into fibrinolytic pathways, contributing to the development of new treatments.

Purchasing Guide

When purchasing the D-Dimer Assay Kit, consider product specifications, types, budget, and intended use to ensure it meets your laboratory's needs.

1. Product Specifications: Ensure the kit meets your laboratory's requirements for sensitivity, specificity, and stability.
2. Product Types: Choose between different formats and sizes based on your laboratory's throughput and storage capacity.
3. Budget: Consider the cost per test and the overall budget for your laboratory's diagnostic needs.
4. Intended Use: Ensure the kit is suitable for your specific clinical or research applications, such as diagnosing thrombotic disorders or studying fibrinolytic pathways.

Selecting the right D-Dimer Assay Kit involves careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can ensure that the kit meets your laboratory's needs and provides reliable results for your clinical or research applications.

 Precautions

Proper handling and storage of the D-Dimer Assay Kit are essential to ensure accurate results and maintain the integrity of the reagents.

1. Storage Conditions: Store the kit at the recommended temperature to maintain the stability of the reagents.
2. Handling: Follow the manufacturer's instructions for handling the reagents to avoid contamination and ensure accurate results.
3. Expiration Date: Always check the expiration date before using the kit to ensure the reagents are still effective.
4. Calibration: Regularly calibrate the equipment used with the kit to maintain accuracy and reliability.
5. Safety: Wear appropriate personal protective equipment (PPE) when handling the reagents to avoid exposure and ensure safety.

Proper handling and storage of the D-Dimer Assay Kit are crucial for obtaining accurate and reliable results. By following the manufacturer's instructions and adhering to safety protocols, you can ensure the integrity of the reagents and the safety of laboratory personnel.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files