Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Assay Kit (Latex-Enhanced Turbidimetric Method)
The D-Dimer Assay Kit consists of two main reagents: Reagent 1 (R1) contains phosphate buffer and surfactants, while Reagent 2 (R2) includes phosphate buffer, surfactants, and latex particles sensitized with mouse anti-human D-Dimer antibodies. This combination ensures accurate and reliable measurement of D-Dimer levels in human serum.
Product English Name:
D-Dimer Assay Kit (Latex-Enhanced Turbidimetric Method)
Alias:
D-Dimer Test Kit,D-Dimer Quantitative Kit
Intended Use:
This kit is designed for the quantitative determination of D-Dimer levels in human serum. It is widely used in clinical settings to aid in the diagnosis of thrombotic disorders, such as deep vein thrombosis (DVT) and pulmonary embolism (PE).
Product Introduction

The D-Dimer Assay Kit (Latex-Enhanced Turbidimetric Method) is a high-quality diagnostic tool used to measure D-Dimer levels in human serum. D-Dimer is a fibrin degradation product that is elevated in conditions associated with blood clot formation and breakdown. This kit provides a reliable and efficient method for detecting D-Dimer, which is crucial for diagnosing and monitoring thrombotic disorders.

1. The kit features a latex-enhanced turbidimetric method, which enhances sensitivity and specificity in detecting D-Dimer levels. This method is known for its precision and reproducibility, making it a preferred choice in clinical laboratories.
2. The composition of the kit includes two reagents: Reagent 1 (R1) and Reagent 2 (R2). R1 contains phosphate buffer and surfactants, while R2 includes phosphate buffer, surfactants, and latex particles sensitized with mouse anti-human D-Dimer antibodies. This combination ensures accurate and reliable results.
3. The primary use of this kit is to quantitatively determine D-Dimer levels in human serum. It is particularly useful in diagnosing conditions such as deep vein thrombosis (DVT), pulmonary embolism (PE), and disseminated intravascular coagulation (DIC). The kit is also used to monitor the effectiveness of anticoagulant therapy.

The D-Dimer Assay Kit, also known as the D-Dimer Test Kit, is an essential tool in clinical diagnostics. Its latex-enhanced turbidimetric method ensures accurate detection of D-Dimer levels, which is crucial for diagnosing thrombotic disorders. The kit's composition, including sensitized latex particles, enhances its reliability and specificity, making it a trusted choice for healthcare professionals.

Main Features

The D-Dimer Assay Kit offers high sensitivity and specificity in detecting D-Dimer levels, making it an invaluable tool for diagnosing thrombotic disorders. Its latex-enhanced turbidimetric method ensures precise and reproducible results.

1. The kit utilizes a latex-enhanced turbidimetric method, which significantly improves the sensitivity and specificity of D-Dimer detection. This method is particularly effective in distinguishing between normal and elevated D-Dimer levels.
2. The kit includes two reagents: Reagent 1 (R1) and Reagent 2 (R2). R1 contains phosphate buffer and surfactants, while R2 includes phosphate buffer, surfactants, and latex particles sensitized with mouse anti-human D-Dimer antibodies. This combination ensures accurate and reliable results.
3. The kit is designed for the quantitative determination of D-Dimer levels in human serum. It is widely used in clinical settings to aid in the diagnosis of thrombotic disorders, such as deep vein thrombosis (DVT) and pulmonary embolism (PE).
4. The kit is easy to use and provides rapid results, making it suitable for high-throughput laboratories. Its stability and long shelf life further enhance its utility in clinical diagnostics.
5. The kit is compatible with a wide range of automated analyzers, allowing for seamless integration into existing laboratory workflows. This compatibility ensures that the kit can be used efficiently in various clinical settings.

The D-Dimer Assay Kit stands out for its high sensitivity and specificity, thanks to its latex-enhanced turbidimetric method. Its ease of use, rapid results, and compatibility with automated analyzers make it a preferred choice for diagnosing thrombotic disorders in clinical laboratories.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings to diagnose and monitor thrombotic disorders. Its high sensitivity and specificity make it an essential tool for detecting conditions such as deep vein thrombosis (DVT) and pulmonary embolism (PE).

1. The kit is primarily used to diagnose deep vein thrombosis (DVT), a condition where blood clots form in the deep veins of the legs. Elevated D-Dimer levels are a key indicator of DVT, and the kit provides a reliable method for detecting these levels.
2. The kit is also used to diagnose pulmonary embolism (PE), a potentially life-threatening condition where blood clots travel to the lungs. Accurate detection of D-Dimer levels is crucial for timely diagnosis and treatment of PE.
3. In addition to diagnosing DVT and PE, the kit is used to monitor the effectiveness of anticoagulant therapy. By measuring D-Dimer levels over time, healthcare providers can assess the success of treatment and make necessary adjustments.
4. The kit is also used in the diagnosis of disseminated intravascular coagulation (DIC), a condition characterized by widespread blood clotting and bleeding. Elevated D-Dimer levels are a hallmark of DIC, and the kit provides a reliable method for detecting these levels.
5. The kit is used in various clinical settings, including hospitals, clinics, and diagnostic laboratories. Its ease of use and rapid results make it a valuable tool for healthcare providers in diagnosing and managing thrombotic disorders.

The D-Dimer Assay Kit is a versatile tool in clinical diagnostics, widely used for diagnosing and monitoring thrombotic disorders such as DVT, PE, and DIC. Its high sensitivity and specificity, combined with its ease of use, make it an essential resource for healthcare providers in various clinical settings.

Purchasing Guide

When purchasing the D-Dimer Assay Kit, it is important to consider factors such as product specifications, types, budget, and intended use. This guide provides essential information to help you make an informed decision.

1. Product specifications: Ensure that the kit meets your laboratory's requirements, including sensitivity, specificity, and compatibility with your analyzers. Check the shelf life and storage conditions to ensure optimal performance.
2. Product types: The D-Dimer Assay Kit is available in various formats, including manual and automated versions. Choose the type that best suits your laboratory's workflow and throughput needs.
3. Budget considerations: Evaluate the cost of the kit, including any additional reagents or consumables that may be required. Consider the long-term cost-effectiveness of the kit, including its shelf life and stability.
4. Intended use: Determine the primary applications of the kit in your laboratory, such as diagnosing DVT, PE, or DIC. Ensure that the kit's performance characteristics align with your diagnostic needs.

Purchasing the D-Dimer Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can select a kit that meets your laboratory's needs and ensures accurate and reliable results.

 Precautions

When using the D-Dimer Assay Kit, it is important to follow proper handling and storage procedures to ensure accurate results. This section outlines key precautions to consider.

1. Proper storage: Store the kit at the recommended temperature to maintain its stability and performance. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling: Follow the manufacturer's instructions for handling the reagents and samples. Use appropriate personal protective equipment (PPE) to minimize the risk of contamination.
3. Calibration: Regularly calibrate your analyzer to ensure accurate and consistent results. Use the provided calibrators and controls as directed.
4. Sample preparation: Ensure that samples are collected and prepared according to the recommended procedures. Avoid hemolysis or contamination, as these can affect the accuracy of the results.
5. Disposal: Dispose of used reagents and samples in accordance with local regulations. Follow proper biohazard disposal procedures to ensure safety.

Using the D-Dimer Assay Kit requires careful attention to storage, handling, calibration, sample preparation, and disposal. By following these precautions, you can ensure accurate and reliable results while maintaining a safe laboratory environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files