D-Dimer Assay Kit (Chemiluminescent Immunoassay)
The D-Dimer Assay Kit consists of a solid-phase conjugate suspension, a luminescent conjugate solution, calibrators, and quality control materials. These components are designed to work together to provide accurate and reliable quantitative measurements of D-Dimer levels in human plasma.
Product English Name:
D-Dimer Assay Kit (Chemiluminescent Immunoassay)
Alias:
D-Dimer Test Kit,D-Dimer Detection Kit
Intended Use:
This kit is intended for use by medical institutions to quantitatively detect the concentration of cross-linked fibrin degradation product D-Dimer in human plasma. It serves as an auxiliary diagnostic tool for conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
Product Introduction

The D-Dimer Assay Kit (Chemiluminescent Immunoassay) is a sophisticated diagnostic tool designed for the quantitative measurement of D-Dimer levels in human plasma. Utilizing advanced chemiluminescent immunoassay technology, this kit offers high sensitivity and specificity, making it an essential component in the diagnosis and management of thrombotic disorders.

1. The D-Dimer Assay Kit is characterized by its high sensitivity and specificity, ensuring accurate detection of D-Dimer levels even at low concentrations. The kit employs a chemiluminescent immunoassay method, which provides a robust and reliable measurement platform.
2. The kit is composed of several key components: a solid-phase conjugate suspension, a luminescent conjugate solution, calibrators, and quality control materials. Each component is meticulously designed to ensure optimal performance and reproducibility in clinical settings.
3. The primary use of the D-Dimer Assay Kit is to assist in the diagnosis of thrombotic disorders such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation. By providing quantitative measurements of D-Dimer levels, the kit aids clinicians in making informed diagnostic and therapeutic decisions.

The D-Dimer Assay Kit, also known as the D-Dimer Test Kit, is a vital diagnostic tool in modern medicine. Its high sensitivity and specificity, combined with its robust composition, make it an indispensable resource for clinicians dealing with thrombotic disorders. The kit's ability to provide accurate and reliable quantitative measurements of D-Dimer levels ensures that it remains a cornerstone in the diagnosis and management of these conditions.

Main Features

The D-Dimer Assay Kit offers a range of features designed to enhance diagnostic accuracy and reliability. These include high sensitivity, specificity, and a robust chemiluminescent immunoassay method.

1. High Sensitivity: The kit is capable of detecting D-Dimer levels at very low concentrations, ensuring that even minor elevations are accurately measured.
2. Specificity: The assay is highly specific for D-Dimer, minimizing the risk of cross-reactivity with other substances in the plasma.
3. Chemiluminescent Immunoassay: This method provides a robust and reliable platform for quantitative measurement, ensuring consistent results across different clinical settings.
4. Calibrators and Quality Control: The kit includes calibrators and quality control materials to ensure accurate and reproducible results, enhancing the reliability of the assay.
5. Ease of Use: The kit is designed for ease of use, with clear instructions and a straightforward protocol that can be easily followed by laboratory personnel.

The D-Dimer Assay Kit stands out for its high sensitivity, specificity, and the use of advanced chemiluminescent immunoassay technology. These features, combined with its ease of use and reliable performance, make it an essential tool for clinicians in the diagnosis and management of thrombotic disorders.

Clinical Applications

The D-Dimer Assay Kit is widely used in clinical settings for the diagnosis and management of thrombotic disorders. Its applications include the detection of deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.

1. Deep Vein Thrombosis (DVT): The kit is used to detect elevated D-Dimer levels, which are indicative of DVT. This aids in the early diagnosis and management of the condition.
2. Pulmonary Embolism (PE): Elevated D-Dimer levels are also associated with PE. The kit provides a reliable method for detecting these elevations, aiding in the diagnosis and treatment of PE.
3. Disseminated Intravascular Coagulation (DIC): The kit is used to monitor D-Dimer levels in patients with DIC, providing valuable information for the management of this complex condition.
4. Post-Surgical Monitoring: The kit is also used to monitor D-Dimer levels in patients post-surgery, helping to identify any thrombotic complications early.
5. General Thrombosis Screening: The kit is used in general thrombosis screening, providing a reliable method for detecting elevated D-Dimer levels in a variety of clinical scenarios.

The D-Dimer Assay Kit is a versatile tool in clinical practice, with applications ranging from the diagnosis of deep vein thrombosis and pulmonary embolism to the monitoring of disseminated intravascular coagulation. Its reliability and accuracy make it an indispensable resource for clinicians dealing with thrombotic disorders.

Purchasing Guide

The procurement of the D-Dimer Assay Kit requires careful consideration of product parameters, types, budget, and intended use scenarios. This guide provides essential information to assist in the purchasing process.

1. Product Parameters: When purchasing the D-Dimer Assay Kit, it is important to consider the specific parameters of the kit, such as sensitivity, specificity, and the range of detection. These parameters will determine the suitability of the kit for your clinical needs.
2. Product Types: The kit is available in different configurations, including single-use and multi-use options. Consider the volume of testing required and choose the appropriate type to ensure cost-effectiveness and efficiency.
3. Procurement Budget: The cost of the kit should be balanced against its performance and the volume of testing required. Consider the long-term benefits of investing in a high-quality kit that offers reliable and accurate results.
4. Use Scenarios: The intended use of the kit should guide the purchasing decision. Consider the specific clinical scenarios in which the kit will be used, such as emergency settings, routine screening, or specialized diagnostic procedures.

Procuring the D-Dimer Assay Kit involves careful consideration of various factors, including product parameters, types, budget, and intended use scenarios. By taking these factors into account, you can ensure that you select a kit that meets your clinical needs and provides reliable and accurate results.

 Precautions

When using the D-Dimer Assay Kit, it is important to follow specific precautions to ensure accurate results and maintain safety. These precautions include proper handling, storage, and disposal of the kit components.

1. Proper Handling: Always handle the kit components with care, following the manufacturer's instructions. Avoid contamination of the reagents and ensure that all components are used within their specified shelf life.
2. Storage Conditions: Store the kit components at the recommended temperature to maintain their stability and performance. Improper storage can lead to degradation of the reagents and inaccurate results.
3. Disposal: Dispose of used kit components according to local regulations and guidelines. Ensure that all biohazardous materials are properly contained and disposed of to prevent contamination and ensure safety.
4. Calibration and Quality Control: Regularly calibrate the assay and perform quality control checks to ensure the accuracy and reliability of the results. Follow the manufacturer's guidelines for calibration and quality control procedures.
5. Training: Ensure that all personnel using the kit are properly trained in its use and understand the importance of following the specified procedures. Proper training is essential to ensure accurate results and maintain safety.

Using the D-Dimer Assay Kit requires adherence to specific precautions to ensure accurate results and maintain safety. Proper handling, storage, and disposal of the kit components, along with regular calibration and quality control, are essential for reliable performance. Ensuring that all personnel are properly trained is also crucial for the effective use of the kit.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files