The D-Dimer Detection Kit (Quantum Dot Fluorescence Immunoassay) is a cutting-edge diagnostic tool designed for the precise measurement of D-Dimer levels in human blood. Utilizing advanced quantum dot technology, this kit offers high sensitivity and specificity, making it an essential tool in clinical laboratories for the diagnosis and monitoring of thrombotic conditions.
1. The kit features a unique quantum dot fluorescence immunoassay technology, which enhances the detection sensitivity and accuracy of D-Dimer levels. This technology allows for the rapid and reliable quantification of D-Dimer, even at low concentrations.
2. The kit's composition includes a detection card with a test strip, desiccant, and aluminum foil bag. The test strip is made up of multiple layers, including absorbent paper, nitrocellulose membrane, sample pad, conjugate pad, PVC backing, and plastic casing. Each component is meticulously designed to ensure optimal performance and stability.
3. The primary use of this kit is in clinical settings for the quantitative detection of D-Dimer in human plasma and whole blood. It is particularly useful in diagnosing conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
The D-Dimer Detection Kit, also known as the Quantum Dot D-Dimer Assay, is a sophisticated diagnostic tool that leverages quantum dot technology for accurate D-Dimer measurement. Its robust design and high sensitivity make it indispensable in clinical laboratories for diagnosing and monitoring thrombotic disorders.
The D-Dimer Detection Kit offers high sensitivity, specificity, and rapid results, making it a reliable tool for clinical diagnostics.
1. High Sensitivity: The quantum dot fluorescence immunoassay technology ensures the detection of even low concentrations of D-Dimer with high precision.
2. Specificity: The kit is designed to specifically detect D-Dimer, minimizing cross-reactivity with other substances in the blood.
3. Rapid Results: The assay provides quick results, enabling timely diagnosis and treatment of thrombotic conditions.
4. User-Friendly: The kit is easy to use, with clear instructions and minimal sample preparation required.
5. Stability: The components of the kit are designed to maintain stability over a wide range of storage conditions, ensuring reliable performance.
The D-Dimer Detection Kit stands out for its high sensitivity, specificity, and rapid results. Its user-friendly design and stability make it a preferred choice for clinical laboratories in diagnosing thrombotic disorders.
The D-Dimer Detection Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
1. Deep Vein Thrombosis (DVT): The kit is used to detect elevated D-Dimer levels, which are indicative of DVT, a condition where blood clots form in deep veins, usually in the legs.
2. Pulmonary Embolism (PE): Elevated D-Dimer levels are also associated with PE, a potentially life-threatening condition where blood clots travel to the lungs.
3. Disseminated Intravascular Coagulation (DIC): The kit aids in diagnosing DIC, a condition characterized by widespread blood clotting and bleeding.
4. Monitoring Anticoagulant Therapy: The kit is used to monitor the effectiveness of anticoagulant therapy in patients with thrombotic disorders.
5. Preoperative Screening: The kit is employed in preoperative screening to assess the risk of thrombotic events during surgery.
The D-Dimer Detection Kit is a versatile tool in clinical practice, essential for diagnosing and monitoring thrombotic conditions. Its applications range from detecting DVT and PE to monitoring anticoagulant therapy and preoperative screening.
When purchasing the D-Dimer Detection Kit, consider product specifications, types, budget, and usage scenarios to ensure it meets your clinical needs.
1. Product Specifications: Evaluate the kit's sensitivity, specificity, and detection range to ensure it aligns with your diagnostic requirements.
2. Product Types: Choose between different kit configurations, such as those with or without optional components like the assay table storage device and pipette.
3. Budget: Consider the cost-effectiveness of the kit, including the price per test and the overall value it provides in terms of accuracy and reliability.
4. Usage Scenarios: Assess the kit's suitability for your clinical setting, including the volume of tests required and the ease of integration into your laboratory workflow.
Purchasing the D-Dimer Detection Kit requires careful consideration of product specifications, types, budget, and usage scenarios. Ensuring the kit meets your clinical needs will enhance diagnostic accuracy and efficiency.
Proper handling, storage, and usage of the D-Dimer Detection Kit are crucial to ensure accurate results and maintain the integrity of the components.
1. Storage Conditions: Store the kit at the recommended temperature to prevent degradation of the components. Avoid exposure to extreme temperatures and humidity.
2. Handling: Handle the kit components with care to avoid contamination. Use gloves and follow aseptic techniques when preparing and handling samples.
3. Expiration Date: Always check the expiration date before use. Do not use expired components as they may yield inaccurate results.
4. Cross-Contamination: Avoid cross-contamination by using separate pipettes and tips for different samples. Clean and disinfect work surfaces regularly.
5. Disposal: Dispose of used components according to local regulations for biohazardous waste. Follow proper disposal procedures to ensure safety and compliance.