Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Detection Kit (Fluorescent Immunochromatography)
The D-Dimer Detection Kit is composed of a detection card, an ID card, and a sample diluent. The detection card includes a plastic shell and a test strip, which consists of a sample pad, nitrocellulose membrane (with T-line coated with D-Dimer monoclonal antibody I and C-line coated with goat anti-mouse IgG antibody), a conjugate pad (containing fluorescent-labeled D-Dimer monoclonal antibody II), absorbent paper, and a PVC backing board. The sample diluent is a pH 7.4 phosphate buffer with 0.5% sodium caseinate and 1% surfactant.
Product English Name:
D-Dimer Detection Kit (Fluorescent Immunochromatography)
Alias:
D-Dimer Test Kit,FIC D-Dimer Kit
Intended Use:
This kit is designed for the in vitro quantitative determination of D-Dimer levels in human plasma. It is widely used in clinical settings to assist in the diagnosis and monitoring of thrombotic disorders, such as deep vein thrombosis (DVT) and pulmonary embolism (PE).
Product Introduction

The D-Dimer Detection Kit (Fluorescent Immunochromatography) is a state-of-the-art diagnostic tool used to measure D-Dimer levels in human plasma. D-Dimer is a fibrin degradation product that is typically elevated in patients with thrombotic conditions. This kit employs a fluorescent immunochromatographic method, which offers high sensitivity and specificity, making it an essential tool in clinical laboratories.

1. The kit features a unique design that ensures rapid and accurate results. The detection card is easy to use, and the fluorescent labeling provides a clear and measurable signal, enhancing the reliability of the test.
2. The composition of the kit includes a detection card with a nitrocellulose membrane coated with specific antibodies, a conjugate pad with fluorescent-labeled antibodies, and a sample diluent that ensures optimal conditions for the reaction. This combination allows for precise detection of D-Dimer levels.
3. The primary use of this kit is in the diagnosis and monitoring of thrombotic disorders. It is particularly useful in emergency settings where quick and accurate results are crucial for patient management.

The D-Dimer Detection Kit is a reliable and efficient tool for measuring D-Dimer levels in human plasma. Its unique design and high sensitivity make it an invaluable asset in clinical laboratories, particularly in the diagnosis of thrombotic disorders. The kit's ease of use and rapid results further enhance its utility in various medical settings.

Main Features

The D-Dimer Detection Kit offers high sensitivity and specificity, rapid results, and ease of use, making it an essential tool for clinical diagnostics.

1. High Sensitivity: The kit is designed to detect even low levels of D-Dimer, ensuring accurate diagnosis of thrombotic conditions.
2. Rapid Results: The fluorescent immunochromatographic method provides results within minutes, which is crucial in emergency settings.
3. Ease of Use: The detection card is user-friendly, requiring minimal training for operation.
4. Specificity: The use of specific antibodies ensures that the test is highly specific for D-Dimer, reducing the risk of false positives.
5. Stability: The components of the kit are stable under various storage conditions, ensuring reliable performance over time.

The D-Dimer Detection Kit stands out for its high sensitivity, rapid results, and ease of use. These features make it an indispensable tool in clinical diagnostics, particularly in the fast-paced environment of emergency medicine. Its specificity and stability further enhance its reliability, ensuring accurate and consistent results.

Clinical Applications

The D-Dimer Detection Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic disorders, such as deep vein thrombosis and pulmonary embolism.

1. Diagnosis of DVT: The kit is used to detect elevated D-Dimer levels, which are indicative of deep vein thrombosis.
2. Monitoring PE: It is also used to monitor patients with pulmonary embolism, helping to assess the effectiveness of treatment.
3. Emergency Settings: The rapid results provided by the kit are particularly useful in emergency departments, where quick diagnosis is critical.
4. Post-Surgical Monitoring: The kit is used to monitor patients post-surgery to detect any signs of thrombotic complications.
5. Research Applications: The kit is also used in research settings to study the role of D-Dimer in various thrombotic and inflammatory conditions.

The D-Dimer Detection Kit is a versatile tool in clinical practice, used for the diagnosis and monitoring of thrombotic disorders. Its rapid results and high sensitivity make it particularly valuable in emergency settings, while its use in post-surgical monitoring and research further underscores its importance in modern medicine.

Purchasing Guide

When purchasing the D-Dimer Detection Kit, consider factors such as product specifications, types, budget, and intended use to ensure you select the right product for your needs.

1. Product Specifications: Ensure that the kit meets the required sensitivity and specificity for your clinical applications.
2. Product Types: There are different types of D-Dimer kits available, so choose one that best fits your laboratory's needs.
3. Budget: Consider the cost of the kit, including any additional reagents or equipment that may be required.
4. Intended Use: Determine the primary use of the kit, whether for routine diagnostics, emergency settings, or research, to ensure it meets your requirements.

Selecting the right D-Dimer Detection Kit involves careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that the kit you choose will meet your clinical or research needs effectively.

 Precautions

Proper handling and storage of the D-Dimer Detection Kit are essential to ensure accurate results and maintain the integrity of the components.

1. Storage Conditions: Store the kit at the recommended temperature to maintain the stability of the reagents.
2. Handling: Use gloves and other protective equipment when handling the kit to avoid contamination.
3. Expiration Date: Always check the expiration date before use to ensure the reagents are still effective.
4. Sample Preparation: Follow the recommended procedures for sample preparation to avoid errors in the test results.
5. Disposal: Dispose of used components according to biohazard waste disposal guidelines to ensure safety.

To ensure the accuracy and reliability of the D-Dimer Detection Kit, it is crucial to follow proper storage, handling, and disposal procedures. By adhering to these precautions, you can maintain the integrity of the kit and obtain consistent, reliable results.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files