D-Dimer Test Kit (Colloidal Gold Method)
The D-Dimer Test Kit is composed of a detection card and a sample diluent. The detection card includes a test strip housed in a plastic casing. The test strip consists of a sample pad, a gold conjugate pad, a nitrocellulose membrane, an absorbent pad, and a PVC backing. The gold conjugate pad contains D-Dimer labeled antibodies, while the nitrocellulose membrane has a test line with D-Dimer coated antibodies and a control line with goat anti-mouse IgG. The kit is available in single-use packaging for 25 tests per box.
Product English Name:
D-Dimer Test Kit (Colloidal Gold Method)
Alias:
D-Dimer Rapid Test Kit,D-Dimer Assay Kit
Intended Use:
This kit is designed for the qualitative detection of D-Dimer in human plasma or venous whole blood. It is commonly used in clinical settings to assist in the diagnosis of conditions related to blood clotting disorders, such as deep vein thrombosis (DVT) and pulmonary embolism (PE).
Product Introduction

The D-Dimer Test Kit (Colloidal Gold Method) is a rapid diagnostic tool used to detect the presence of D-Dimer, a fibrin degradation product, in human blood. This kit is essential for clinicians to quickly assess the likelihood of thrombotic events. It is designed for ease of use, providing reliable results within minutes, making it a valuable asset in emergency and routine clinical settings.

1. The D-Dimer Test Kit features a user-friendly design with a clear visual readout. The colloidal gold method ensures high sensitivity and specificity, making it a reliable tool for detecting D-Dimer levels in blood samples.
2. The kit's structure includes a detection card with a test strip that contains multiple layers: a sample pad, a gold conjugate pad, a nitrocellulose membrane, and an absorbent pad. Each layer plays a crucial role in the accurate detection of D-Dimer.
3. The primary use of this kit is to aid in the diagnosis of thrombotic disorders. It is particularly useful in emergency rooms and outpatient clinics where rapid results are necessary for timely decision-making.

The D-Dimer Test Kit, also known as the D-Dimer Rapid Test Kit, is a vital diagnostic tool in the medical field. Its straightforward design and reliable performance make it a go-to choice for clinicians needing quick and accurate D-Dimer level assessments.

Main Features

The D-Dimer Test Kit offers rapid and accurate detection of D-Dimer levels in blood samples. Its key features include high sensitivity, ease of use, and quick results, making it ideal for clinical settings.

1. High Sensitivity: The kit is designed to detect even low levels of D-Dimer, ensuring accurate diagnosis of thrombotic conditions.
2. Rapid Results: Results are available within minutes, allowing for quick clinical decision-making.
3. User-Friendly: The kit is easy to use, with clear instructions and a simple visual readout.
4. Reliable Performance: The colloidal gold method ensures consistent and reliable results across different samples.
5. Compact Design: The kit is compact and portable, making it suitable for use in various clinical environments.

The D-Dimer Test Kit stands out for its high sensitivity, rapid results, and user-friendly design. These features make it an indispensable tool for clinicians dealing with thrombotic disorders.

Clinical Applications

The D-Dimer Test Kit is widely used in clinical settings to diagnose and monitor thrombotic disorders. Its rapid and accurate results make it a valuable tool in emergency and routine care.

1. Emergency Rooms: The kit is used to quickly assess patients with suspected DVT or PE, aiding in timely treatment decisions.
2. Outpatient Clinics: It is used for routine monitoring of patients with a history of thrombotic disorders.
3. Hospitals: The kit is employed in various hospital departments for rapid D-Dimer testing.
4. Laboratories: It is used in clinical laboratories for high-throughput D-Dimer testing.
5. Research: The kit is also used in research settings to study thrombotic disorders and their treatments.

The D-Dimer Test Kit is a versatile tool in clinical practice, offering rapid and accurate D-Dimer detection. Its applications span emergency care, routine monitoring, and research, making it a valuable asset in the medical field.

Purchasing Guide

When purchasing the D-Dimer Test Kit, consider factors such as product specifications, types, budget, and intended use to ensure you select the right kit for your needs.

1. Product Specifications: Ensure the kit meets your required sensitivity and specificity levels. Check the components and their quantities to match your testing volume.
2. Product Types: Choose between different formats, such as single-use or multi-use kits, based on your clinical needs.
3. Budget: Consider the cost per test and the overall budget for your clinical setting. Look for kits that offer the best value without compromising quality.
4. Usage Scenarios: Evaluate the kit's suitability for your specific clinical environment, whether it's an emergency room, outpatient clinic, or laboratory.

Selecting the right D-Dimer Test Kit involves careful consideration of product specifications, types, budget, and usage scenarios. By evaluating these factors, you can ensure you choose a kit that meets your clinical needs effectively.

 Precautions

When using the D-Dimer Test Kit, it is important to follow proper handling and storage procedures to ensure accurate results and maintain the kit's integrity.

1. Storage: Store the kit at the recommended temperature to prevent degradation of components. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling: Use gloves and other protective equipment when handling blood samples and kit components to prevent contamination.
3. Expiration: Check the expiration date before use. Do not use expired kits as they may yield inaccurate results.
4. Disposal: Dispose of used components according to biohazard waste disposal guidelines to ensure safety and compliance.
5. Training: Ensure that all personnel using the kit are properly trained in its use to avoid errors and ensure consistent results.

Proper handling, storage, and disposal of the D-Dimer Test Kit are crucial for maintaining its effectiveness and ensuring accurate results. By following these precautions, you can maximize the kit's performance and safety in your clinical setting.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files