D-Dimer Detection Kit (Direct Chemiluminescence Method)
The kit consists of R1, R2, R3, an instruction manual, and an RFID card (or QR code). R1 contains magnetic microparticles coated with mouse anti-human D-Dimer monoclonal antibody at approximately 3μg/mL, along with 0.5% bovine serum albumin, 1% sucrose, 0.5% trehalose, 0.2% Tween 20, and 0.05% Proclin 300 in a 0.05mol/L Tris-HCl buffer (pH 7.4±0.5). R2 contains acridinium ester-labeled mouse anti-human D-Dimer monoclonal antibody at approximately 2μg/mL, with 0.5% bovine serum albumin, 1% trehalose, 0.93% sodium dihydrogen phosphate, 0.32% disodium hydrogen phosphate, 0.88% sodium chloride, 0.1% Tween 20, and 0.05% Proclin 300 in an aqueous solution. R3 is a sample diluent containing 0.2% skimmed milk powder and 0.05% Proclin 300 in a 0.01mol/L phosphate buffer (pH 7.4±0.5). The RFID card (or QR code) contains the main calibration curve information.
Product English Name:
D-Dimer Detection Kit (Direct Chemiluminescence Method)
Alias:
D-Dimer Test Kit,D-Dimer Assay Kit
Intended Use:
This kit is used for the quantitative detection of D-Dimer levels in human plasma in vitro. It is widely applied in clinical diagnostics to assess conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
Product Introduction

The D-Dimer Detection Kit (Direct Chemiluminescence Method) is a sophisticated diagnostic tool designed for the precise measurement of D-Dimer levels in human plasma. Utilizing advanced chemiluminescence technology, this kit offers high sensitivity and specificity, making it an essential tool in clinical laboratories for diagnosing thrombotic disorders.

1. The kit features a highly sensitive chemiluminescence detection system, ensuring accurate and reliable results. The use of magnetic microparticles and acridinium ester-labeled antibodies enhances the detection efficiency and reduces background noise.
2. The composition of the kit includes R1, R2, R3, an instruction manual, and an RFID card (or QR code). Each component is meticulously formulated to ensure stability and performance, with precise concentrations of antibodies, buffers, and stabilizers.
3. The primary use of this kit is for the quantitative detection of D-Dimer in human plasma, aiding in the diagnosis and monitoring of thrombotic conditions. It is particularly useful in emergency settings where rapid and accurate results are crucial.

The D-Dimer Detection Kit is a reliable and efficient tool for clinical diagnostics. Its advanced chemiluminescence technology and precise formulation make it indispensable for detecting thrombotic disorders. The kit's components are carefully designed to ensure stability and accuracy, providing clinicians with the confidence they need in their diagnostic processes.

Main Features

The D-Dimer Detection Kit offers high sensitivity and specificity, utilizing chemiluminescence technology for accurate D-Dimer measurement. It is designed for ease of use and reliability in clinical settings.

1. High sensitivity: The kit can detect low concentrations of D-Dimer, making it suitable for early diagnosis of thrombotic disorders.
2. Specificity: The use of monoclonal antibodies ensures minimal cross-reactivity, providing accurate results.
3. Stability: The components are formulated to maintain stability over a wide range of storage conditions.
4. Ease of use: The kit includes a detailed instruction manual and an RFID card (or QR code) for easy calibration.
5. Rapid results: The chemiluminescence method allows for quick detection, which is crucial in emergency situations.

The D-Dimer Detection Kit stands out for its high sensitivity, specificity, and ease of use. Its advanced technology and stable formulation make it a reliable choice for clinicians, ensuring accurate and rapid results in critical diagnostic scenarios.

Clinical Applications

The D-Dimer Detection Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic disorders, including deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.

1. Diagnosis of deep vein thrombosis (DVT): The kit is used to measure D-Dimer levels, which are elevated in patients with DVT.
2. Pulmonary embolism (PE) detection: Elevated D-Dimer levels are indicative of PE, and the kit provides rapid and accurate results.
3. Monitoring disseminated intravascular coagulation (DIC): The kit helps in assessing the severity and progression of DIC.
4. Preoperative screening: The kit is used to assess the risk of thrombosis in patients undergoing surgery.
5. Emergency settings: The rapid detection capability of the kit is crucial in emergency departments for timely diagnosis and treatment.

The D-Dimer Detection Kit is an invaluable tool in clinical practice, particularly for diagnosing and monitoring thrombotic disorders. Its rapid and accurate results make it essential in emergency and preoperative settings, ensuring timely and effective patient care.

Purchasing Guide

This guide provides essential information for purchasing the D-Dimer Detection Kit, including product specifications, types, budget considerations, and usage scenarios.

1. Product specifications: Ensure the kit meets the required sensitivity, specificity, and stability standards for your laboratory needs.
2. Product types: Choose between different kit formats, such as single-use or bulk packs, based on your laboratory's volume and frequency of use.
3. Budget considerations: Evaluate the cost-effectiveness of the kit, considering factors like shelf life, storage requirements, and the number of tests per kit.
4. Usage scenarios: Consider the specific clinical applications and settings where the kit will be used, such as emergency departments, outpatient clinics, or research laboratories.

Purchasing the D-Dimer Detection Kit requires careful consideration of product specifications, types, budget, and usage scenarios. By evaluating these factors, you can ensure that the kit meets your laboratory's needs and provides reliable and accurate results for your clinical applications.

 Precautions

Proper handling and storage of the D-Dimer Detection Kit are crucial to ensure accurate results and maintain the integrity of the components.

1. Storage conditions: Store the kit at the recommended temperature to maintain the stability of the reagents.
2. Handling: Use aseptic techniques to avoid contamination of the samples and reagents.
3. Calibration: Regularly calibrate the equipment using the provided RFID card (or QR code) to ensure accurate results.
4. Disposal: Follow proper disposal procedures for used reagents and materials to comply with safety regulations.
5. Training: Ensure that all personnel using the kit are adequately trained in its operation and maintenance.

Adhering to proper storage, handling, and disposal procedures is essential for the effective use of the D-Dimer Detection Kit. Regular calibration and training of personnel further ensure the accuracy and reliability of the results, making the kit a dependable tool in clinical diagnostics.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list