Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Test Kit (Dry Immunofluorescence Method)
The D-Dimer Test Kit (Dry Immunofluorescence Method) is composed of single-use test cards, each containing a test strip housed within a casing. The test strip includes a sample pad, a fluorescence pad coated with fluorescently labeled D-Dimer monoclonal antibody I (0.2~0.5 mg/ml), a chromatographic membrane with detection zones coated with D-Dimer monoclonal antibodies II (0.5~1.5 mg/ml) and III (0.1~0.3 mg/ml), a control zone coated with rabbit anti-mouse IgG antibody (0.5~2.0 mg/ml), absorbent paper, and a backing pad. The kit also includes a user manual, an SD card compatible with various Getein models, optional pipettes, and detection buffer tubes containing phosphate (20 mM), protein stabilizers (0.1% preservative), surfactants (1.0% Tween), with a pH of 7.2±0.2.
Product English Name:
D-Dimer Test Kit (Dry Immunofluorescence Method)
Alias:
D-Dimer Assay Kit,D-Dimer Diagnostic Kit
Intended Use:
The D-Dimer Test Kit is designed for the quantitative measurement of D-Dimer levels in human whole blood and plasma. It is widely used in clinical settings to assist in the diagnosis and monitoring of conditions related to blood clotting disorders, such as deep vein thrombosis (DVT), pulmonary embolism (PE), and disseminated intravascular coagulation (DIC).
Product Introduction

The D-Dimer Test Kit (Dry Immunofluorescence Method) is a state-of-the-art diagnostic tool designed for the accurate and rapid quantification of D-Dimer levels in human blood. Utilizing advanced immunofluorescence technology, this kit provides reliable results that are essential for the diagnosis and management of thrombotic disorders. The kit is user-friendly, with a simple procedure that ensures quick turnaround times, making it an invaluable resource in both clinical and laboratory settings.

1. The D-Dimer Test Kit features a highly sensitive and specific immunofluorescence detection system. The test strips are designed with precision-engineered components, including a fluorescence pad and chromatographic membrane, which ensure accurate and reproducible results. The kit's design minimizes the risk of cross-reactivity and false positives, providing clinicians with confidence in the results.
2. The composition of the test strip is meticulously crafted to optimize performance. The sample pad ensures even distribution of the sample, while the fluorescence pad, coated with fluorescently labeled antibodies, captures the target D-Dimer molecules. The chromatographic membrane, with its detection and control zones, allows for the precise measurement of D-Dimer levels, ensuring high accuracy and reliability.
3. The primary use of the D-Dimer Test Kit is in the diagnosis and monitoring of thrombotic conditions. By providing quantitative measurements of D-Dimer levels, the kit aids in the early detection of blood clotting disorders, enabling timely intervention and treatment. Its application extends to various clinical scenarios, including emergency departments, outpatient clinics, and research laboratories.

The D-Dimer Test Kit (Dry Immunofluorescence Method) is a reliable and efficient diagnostic tool that plays a crucial role in the management of thrombotic disorders. Its advanced technology, combined with a user-friendly design, makes it an essential resource for healthcare professionals. Whether in a busy clinical setting or a research laboratory, this kit delivers accurate and timely results, helping to improve patient outcomes.

Main Features

The D-Dimer Test Kit offers a range of features designed to enhance diagnostic accuracy and efficiency. Its key features include high sensitivity, specificity, and ease of use, making it a preferred choice for clinicians and researchers alike.

1. High Sensitivity: The kit's immunofluorescence technology ensures the detection of even low levels of D-Dimer, providing early and accurate diagnosis of thrombotic conditions.
2. Specificity: The use of monoclonal antibodies in the test strip minimizes cross-reactivity, ensuring that the results are specific to D-Dimer and reducing the likelihood of false positives.
3. Rapid Results: The test procedure is designed for quick turnaround times, allowing clinicians to make timely decisions in critical situations.
4. User-Friendly Design: The kit's components are easy to handle, and the procedure is straightforward, making it suitable for use in various clinical settings.
5. Versatility: The kit is compatible with a range of Getein models, offering flexibility in its application across different laboratory setups.

The D-Dimer Test Kit stands out for its high sensitivity, specificity, and user-friendly design. These features make it an indispensable tool in the diagnosis and management of thrombotic disorders, providing clinicians with reliable results that are essential for effective patient care.

Clinical Applications

The D-Dimer Test Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic disorders. Its applications extend to emergency departments, outpatient clinics, and research laboratories, where accurate and timely results are crucial.

1. Emergency Departments: The kit is used to quickly assess patients presenting with symptoms of deep vein thrombosis (DVT) or pulmonary embolism (PE), enabling rapid diagnosis and treatment.
2. Outpatient Clinics: In outpatient settings, the kit aids in the ongoing monitoring of patients with known thrombotic conditions, helping to adjust treatment plans as needed.
3. Research Laboratories: Researchers use the kit to study the mechanisms of blood clotting and to develop new diagnostic and therapeutic strategies for thrombotic disorders.
4. Intensive Care Units: In critical care settings, the kit is used to monitor patients at high risk of developing blood clots, ensuring timely intervention.
5. General Practice: The kit is also used in general practice settings to screen patients with risk factors for thrombotic disorders, facilitating early detection and prevention.

The D-Dimer Test Kit is a versatile diagnostic tool with broad applications in clinical practice. Its ability to provide rapid and accurate results makes it an essential resource in the management of thrombotic disorders, from emergency care to ongoing patient monitoring and research.

Purchasing Guide

When purchasing the D-Dimer Test Kit, it is important to consider factors such as product specifications, compatibility with existing equipment, budget, and intended use. This guide provides essential information to help you make an informed decision.

1. Product Specifications: Ensure that the kit's specifications, including sensitivity, specificity, and detection range, meet your diagnostic needs.
2. Compatibility: Verify that the kit is compatible with your laboratory's existing equipment, such as Getein models, to avoid compatibility issues.
3. Budget: Consider the cost of the kit, including any additional components or consumables, to ensure it fits within your budget.
4. Intended Use: Determine the primary use of the kit, whether for emergency care, outpatient monitoring, or research, to select the most appropriate product.

Purchasing the D-Dimer Test Kit requires careful consideration of various factors, including product specifications, compatibility, budget, and intended use. By taking these factors into account, you can ensure that you select the right kit for your diagnostic needs, ultimately improving patient care and outcomes.

 Precautions

When using the D-Dimer Test Kit, it is important to follow the manufacturer's instructions carefully to ensure accurate results and safe handling. This section outlines key precautions to be taken during the use of the kit.

1. Proper Storage: Store the kit at the recommended temperature to maintain the stability and effectiveness of the components.
2. Handling: Handle the test strips and other components with care to avoid contamination or damage, which could affect the results.
3. Sample Preparation: Ensure that blood samples are collected and prepared according to the specified procedures to avoid errors in the test results.
4. Disposal: Dispose of used test strips and other materials in accordance with local regulations to prevent biohazard risks.
5. Training: Ensure that all personnel using the kit are properly trained in its use and interpretation of results to avoid errors and ensure patient safety.

Using the D-Dimer Test Kit safely and effectively requires adherence to proper storage, handling, and disposal procedures. By following these precautions, you can ensure the accuracy of the results and the safety of both patients and healthcare personnel.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files