The D-Dimer Test Kit (Immunoturbidimetric Method) is a highly sensitive and specific diagnostic tool used to measure D-Dimer levels in human blood. D-Dimer is a fibrin degradation product that is elevated in conditions associated with blood clot formation and breakdown. This kit is essential for clinicians to assess the risk of thrombotic events and monitor the effectiveness of anticoagulant therapy.
1. The kit features a rapid and accurate immunoturbidimetric method, which allows for quick results with high precision. The method is based on the interaction between D-Dimer and specific antibodies, leading to the formation of immune complexes that can be measured turbidimetrically.
2. The kit includes two main reagents: Reagent 1, which contains a buffer solution and a sealing cap, and Reagent 2, which consists of polystyrene particles coated with mouse anti-human monoclonal antibodies. An optional calibration card is also provided to ensure accurate measurement.
3. The primary use of this kit is to measure D-Dimer levels in human serum and whole blood. It is particularly useful in diagnosing thrombotic disorders, such as deep vein thrombosis (DVT) and pulmonary embolism (PE), and in monitoring the effectiveness of anticoagulant therapy.
The D-Dimer Test Kit is a reliable and efficient tool for measuring D-Dimer levels in human blood. Its rapid immunoturbidimetric method ensures quick and accurate results, making it an essential diagnostic tool in clinical settings. The kit's components, including the buffer solution, polystyrene particles, and monoclonal antibodies, work together to provide precise measurements, aiding in the diagnosis and management of thrombotic disorders.
The D-Dimer Test Kit offers rapid and accurate detection of D-Dimer levels using an immunoturbidimetric method. It is designed for ease of use in clinical laboratories, providing reliable results for the diagnosis and monitoring of thrombotic disorders.
1. The kit utilizes a highly sensitive immunoturbidimetric method, which allows for the rapid detection of D-Dimer levels in human blood. This method is based on the formation of immune complexes that can be measured turbidimetrically.
2. The kit includes two main reagents: Reagent 1, which contains a buffer solution and a sealing cap, and Reagent 2, which consists of polystyrene particles coated with mouse anti-human monoclonal antibodies. These components work together to ensure accurate and reliable results.
3. The kit is designed for use in clinical laboratories and is compatible with a wide range of automated analyzers. This makes it easy to integrate into existing laboratory workflows, reducing the time and effort required for D-Dimer testing.
4. The kit provides a wide dynamic range for D-Dimer measurement, allowing for the detection of both low and high levels of D-Dimer in human blood. This is particularly useful in diagnosing and monitoring thrombotic disorders.
5. The kit includes an optional calibration card, which ensures accurate and consistent results across different batches and lots. This feature is essential for maintaining the reliability and reproducibility of D-Dimer measurements.
The D-Dimer Test Kit is a versatile and reliable diagnostic tool that offers rapid and accurate detection of D-Dimer levels in human blood. Its immunoturbidimetric method, combined with high-quality reagents and an optional calibration card, ensures precise and consistent results. This makes it an essential tool for clinicians in the diagnosis and management of thrombotic disorders.
The D-Dimer Test Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic disorders, such as deep vein thrombosis (DVT) and pulmonary embolism (PE). It is also used to assess the effectiveness of anticoagulant therapy.
1. The kit is commonly used in emergency departments to quickly assess the risk of thrombotic events in patients presenting with symptoms of DVT or PE. Rapid and accurate D-Dimer measurement is crucial for timely diagnosis and treatment.
2. In outpatient settings, the kit is used to monitor patients on anticoagulant therapy. Regular D-Dimer testing helps clinicians assess the effectiveness of treatment and adjust dosages as needed.
3. The kit is also used in preoperative assessments to evaluate the risk of postoperative thrombotic complications. This is particularly important for patients with a history of thrombotic disorders or those undergoing high-risk surgeries.
4. In research settings, the kit is used to study the role of D-Dimer in various thrombotic and inflammatory conditions. Its high sensitivity and specificity make it a valuable tool for clinical research.
5. The kit is also used in the management of patients with disseminated intravascular coagulation (DIC). D-Dimer levels are often elevated in DIC, and regular monitoring helps clinicians assess the severity of the condition and guide treatment.
The D-Dimer Test Kit is an essential tool in clinical practice, offering rapid and accurate measurement of D-Dimer levels. Its applications range from emergency diagnosis to long-term monitoring of anticoagulant therapy, making it a versatile and valuable asset in the management of thrombotic disorders.
When purchasing the D-Dimer Test Kit, it is important to consider factors such as product specifications, types, budget, and intended use. This guide provides essential information to help you make an informed decision.
1. Product Specifications: Ensure that the kit meets your laboratory's requirements for sensitivity, specificity, and dynamic range. Check the compatibility of the kit with your existing analyzers and equipment.
2. Product Types: The D-Dimer Test Kit is available in different formats, including manual and automated versions. Choose the type that best suits your laboratory's workflow and testing volume.
3. Budget: Consider the cost of the kit, including any additional reagents or calibration cards that may be required. Compare prices from different suppliers to find the best value for your budget.
4. Intended Use: Determine the primary use of the kit in your laboratory, whether for emergency diagnosis, routine monitoring, or research purposes. This will help you select the most appropriate kit for your needs.
Purchasing the D-Dimer Test Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can select a kit that meets your laboratory's needs and ensures accurate and reliable D-Dimer measurements.
When using the D-Dimer Test Kit, it is important to follow proper handling and storage procedures to ensure accurate results and maintain the integrity of the reagents.
1. Storage: Store the kit at the recommended temperature, typically between 2-8°C. Avoid freezing the reagents, as this can affect their performance.
2. Handling: Use aseptic techniques when handling the reagents to prevent contamination. Ensure that all equipment and surfaces are clean and free from contaminants.
3. Expiration: Check the expiration date of the kit before use. Do not use expired reagents, as this can lead to inaccurate results.
4. Calibration: Regularly calibrate the kit using the provided calibration card or standards. This ensures consistent and accurate results over time.
5. Disposal: Dispose of used reagents and materials according to local regulations and guidelines. Follow proper biohazard disposal procedures to ensure safety.
Proper handling and storage of the D-Dimer Test Kit are essential for maintaining the accuracy and reliability of test results. By following the recommended precautions, you can ensure the integrity of the reagents and achieve consistent performance in your laboratory.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.